Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies

被引:11
作者
Cai, Weixing [1 ]
Ning, Ruola [1 ]
Conover, David [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Cone beam CT; scatter correction; breast imaging; X-RAY SCATTER; AIR GAPS; ALGORITHM; RADIATION; REMOVAL;
D O I
10.3233/XST-2010-0280
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In flat-panel detector-based cone beam CT breast imaging (CBCTBI) systems, scattering is an important factor that degrades image quality. It is not practical to measure the scattering profiles of a breast for all view angles in a patient study, but it is possible to develop a method to estimate the scattering profiles based on information acquired from breast phantom studies. A new scattering correction method is proposed for clinical CBCTBI in this study. The scattering profiles of three anthropomorphic uncompressed breast phantoms of different sizes were thoroughly investigated, and the results indicated that though phantom size differed, the scattering profiles were mainly determined by local breast diameters, which are the approximate diameters of coronal slices that are perpendicular to the nipple-to-chestwall direction. Thus for scattering correction purposes it is possible to establish a relationship between location breast diameters and local scattering profiles, namely the fitted smooth curves of scatter-to-primary ratios (SPR) and normalized scattered radiations (NSR). In clinical CBCTBI studies, after the local breast diameters are sampled and measured on projection images, the scattering image for every projection image can be generated based on the established relationship, and the projection images can be corrected using either the SPR based method or the NSR based method. Phantom studies and clinical studies showed that both the SPR and NSR methods are able to correct cupping artifacts and reduce reconstruction error. The SPR method does not increase tissue contrast or noise while the NSR method increases both.
引用
收藏
页码:91 / 109
页数:19
相关论文
共 50 条
[31]   Investigation of the dose distribution for a cone beam CT system dedicated to breast imaging [J].
Lanconelli, Nico ;
Mettivier, Giovanni ;
Lo Meo, Sergio ;
Russo, Paolo .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04) :379-387
[32]   Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information [J].
Lee, Ho ;
Xing, Lei ;
Lee, Rena ;
Fahimian, Benjamin P. .
MEDICAL PHYSICS, 2012, 39 (05) :2386-2395
[33]   Scatter measurement and correction method for cone-beam CT based on single grating scan [J].
Huang, Kuidong ;
Shi, Wenlong ;
Wang, Xinyu ;
Dong, Yin ;
Chang, Taoqi ;
Zhang, Hua ;
Zhang, Dinghua .
OPTICAL ENGINEERING, 2017, 56 (06)
[34]   Scatter correction method for cone-beam CT based on interlacing-slit scan [J].
Huang Kui-Dong ;
Zhang Hua ;
Shi Yi-Kai ;
Zhang Liang ;
Xu Zhe .
CHINESE PHYSICS B, 2014, 23 (09)
[35]   X-ray scatter correction for dedicated cone beam breast CT using a forward-projection model [J].
Shi, Linxi ;
Vedantham, Srinivasan ;
Karellas, Andrew ;
Zhu, Lei .
MEDICAL PHYSICS, 2017, 44 (06) :2312-2320
[36]   Hybrid scatter correction for CT imaging [J].
Baer, Matthias ;
Kachelriess, Marc .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :6849-6867
[37]   A novel hardware duo of beam modulation and shielding to reduce scatter acquisition and dose in cone-beam breast CT [J].
Ghazi, Peymon ;
Youssefian, Sina ;
Ghazi, Tara .
MEDICAL PHYSICS, 2022, 49 (01) :169-185
[38]   Scatter correction for cone-beam CT via scatter kernel superposition-inspired convolutional neural network [J].
Zhuo, Xu ;
Lu, Yuchen ;
Hua, Yuexuan ;
Liu, Hanxi ;
Zhang, Yikun ;
Hao, Shilei ;
Wan, Lin ;
Xie, Qingguo ;
Ji, Xu ;
Chen, Yang .
PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (07)
[39]   Development of a Beam Stop Array System with Dual Scan Mode for Scatter Correction of Cone-beam CT [J].
Ahn, So Hyun ;
Choi, Jinho ;
Lee, Kyu Chan ;
Kim, Siyong ;
Lee, Rena .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (08) :1220-1229
[40]   Geometrical study on two tilting arcs based exact cone-beam CT for breast imaging [J].
Zeng, Kai ;
Yu, Hengyong ;
Fajardo, Laurie L. ;
Wang, Ge .
DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318