Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies

被引:11
|
作者
Cai, Weixing [1 ]
Ning, Ruola [1 ]
Conover, David [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Cone beam CT; scatter correction; breast imaging; X-RAY SCATTER; AIR GAPS; ALGORITHM; RADIATION; REMOVAL;
D O I
10.3233/XST-2010-0280
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In flat-panel detector-based cone beam CT breast imaging (CBCTBI) systems, scattering is an important factor that degrades image quality. It is not practical to measure the scattering profiles of a breast for all view angles in a patient study, but it is possible to develop a method to estimate the scattering profiles based on information acquired from breast phantom studies. A new scattering correction method is proposed for clinical CBCTBI in this study. The scattering profiles of three anthropomorphic uncompressed breast phantoms of different sizes were thoroughly investigated, and the results indicated that though phantom size differed, the scattering profiles were mainly determined by local breast diameters, which are the approximate diameters of coronal slices that are perpendicular to the nipple-to-chestwall direction. Thus for scattering correction purposes it is possible to establish a relationship between location breast diameters and local scattering profiles, namely the fitted smooth curves of scatter-to-primary ratios (SPR) and normalized scattered radiations (NSR). In clinical CBCTBI studies, after the local breast diameters are sampled and measured on projection images, the scattering image for every projection image can be generated based on the established relationship, and the projection images can be corrected using either the SPR based method or the NSR based method. Phantom studies and clinical studies showed that both the SPR and NSR methods are able to correct cupping artifacts and reduce reconstruction error. The SPR method does not increase tissue contrast or noise while the NSR method increases both.
引用
收藏
页码:91 / 109
页数:19
相关论文
共 50 条
  • [1] Scatter Correction for Dedicated Cone Beam Breast CT Based On a Forward Projection Model
    Shi, L.
    Vedantham, S.
    Karellas, A.
    Zhu, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3820 - 3820
  • [2] Library based x-ray scatter correction for dedicated cone beam breast CT
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL PHYSICS, 2016, 43 (08) : 4529 - 4544
  • [3] Library-based scatter correction for dedicated cone beam breast CT: a feasibility study
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [4] Library-Based X-Ray Scatter Correction for Dedicated Cone-Beam Breast CT: Clinical Validation
    Shi, L.
    Vedantham, S.
    Karellas, A.
    Zhu, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3819 - 3819
  • [5] Scatter measurements and simulations in x-ray cone beam CT breast imaging
    Chen, Y.
    Liu, B.
    O'Connor, M.
    Didier, C.
    Glick, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2606 - 2606
  • [6] Emerging Clinical Applications for Cone Beam Breast CT: Changing the Breast Imaging Paradigm
    Siddall, Kristina
    Zhang, Xiaohua
    O'Connell, Avice
    CURRENT BREAST CANCER REPORTS, 2024, 16 (02) : 134 - 141
  • [7] Flat panel detector-based cone beam volume CT breast imaging: Phantom study
    Ning, R
    Chen, B
    Conover, D
    McHugh, L
    Cullinan, JA
    Robinson, AE
    RADIOLOGY, 2001, 221 : 544 - 544
  • [8] The role of off-focus radiation in scatter correction for dedicated cone beam breast CT
    Shi, Linxi
    Vedantham, Srinivasan
    Karellas, Andrew
    Zhu, Lei
    MEDICAL PHYSICS, 2018, 45 (01) : 191 - 201
  • [9] A scanning sampled measurement (SSM) technique for scatter measurement and correction in cone beam breast CT
    Liu, X
    Shaw, C
    Altunbas, M
    Wang, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2093 - 2093
  • [10] Flat panel detector-based cone beam volume CT breast imaging: preliminary phantom study
    Ning, RL
    Chen, BA
    Conover, D
    McHugh, L
    Cullinan, J
    Yu, RF
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 601 - 610