Wire rope isolators for vibration isolation of equipment and structures - A review

被引:28
作者
Balaji, P. S. [1 ]
Rahman, M. E. [1 ]
Moussa, Leblouba [2 ]
Lau, H. H. [1 ]
机构
[1] Curtin Univ Sarawak, Dept Civil & Construct Engn, Miri, Sarawak, Malaysia
[2] Univ Sharjah, Dept Civil & Environm Engn, Sharjah, U Arab Emirates
来源
9TH CURTIN UNIVERSITY OF TECHNOLOGY SCIENCE AND ENGINEERING INTERNATIONAL CONFERENCE 2014 (CUTSE2014) | 2015年 / 78卷
关键词
IDENTIFICATION; DAMPERS; SYSTEMS;
D O I
10.1088/1757-899X/78/1/012001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Vibrations and shocks are studied using various techniques and analyzed to predict their detrimental effect on the equipment and structures. In cases, where the effects of vibration become unacceptable, it may cause structural damage and affect the operation of the equipment. Hence, adding a discrete system to isolate the vibration from source becomes necessary. The Wire Rope Isolator (WRI) can be used to effectively isolate the system from disturbing vibrations. The WRI is a type of passive isolator that exhibits nonlinear behavior. It consists of stranded wire rope held between two metal retainer bars and the metal wire rope is made up of individual wire strands that are in frictional contact with each other, hence, it is a kind of friction-type isolator. This paper compiles the research work on wire rope isolators. This paper presents the research work under two categories, namely monotonic and cyclic loading behaviors of WRI. The review also discusses the different terminologies associated with vibration isolation system and highlights the comparison between various isolation systems.
引用
收藏
页数:10
相关论文
共 43 条
[1]   A NEW CONCEPT IN SEMI-ACTIVE VIBRATION ISOLATION [J].
ALANOLY, J ;
SANKAR, S .
JOURNAL OF MECHANISMS TRANSMISSIONS AND AUTOMATION IN DESIGN-TRANSACTIONS OF THE ASME, 1987, 109 (02) :242-247
[2]   A parametric study of linear and non-linear passively damped seismic isolation systems for buildings [J].
Alhan, C ;
Gavin, H .
ENGINEERING STRUCTURES, 2004, 26 (04) :485-497
[3]  
[Anonymous], VIBRATION CONTROL AC
[4]  
[Anonymous], 2014, WIR ROP IS
[5]  
[Anonymous], 2014, SHOCK VIBR CONTR WIR
[6]  
[Anonymous], 2003, Passive vibration isolation
[7]   Experimental calibration of forward and inverse neural networks for rotary type magnetorheological damper [J].
Bhowmik, Subrata ;
Weber, Felix ;
Hogsberg, Jan .
STRUCTURAL ENGINEERING AND MECHANICS, 2013, 46 (05) :673-693
[8]   STUDY OF WIRE ROPE SYSTEMS FOR SEISMIC PROTECTION OF EQUIPMENT IN BUILDINGS [J].
DEMETRIADES, GF ;
CONSTANTINOU, MC ;
REINHORN, AM .
ENGINEERING STRUCTURES, 1993, 15 (05) :321-334
[9]   Sensitive equipments on WRS-BTU isolators [J].
Di Massa, Giandomenico ;
Pagano, Stefano ;
Rocca, Ernesto ;
Strano, Salvatore .
MECCANICA, 2013, 48 (07) :1777-1790
[10]   Modeling and application of MR dampers in semi-adaptive structures [J].
Dominguez, A. ;
Sedaghati, R. ;
Stiharu, I. .