Characteristics of dynamic processing in the visual field of patients with age-related maculopathy

被引:11
作者
Eisenbarth, Werner
MacKeben, Manfred
Poggel, Dorothe A.
Strasburger, Hans [1 ]
机构
[1] Univ Gottingen, Dept Med Psychol, Gottingen, Germany
[2] Boston VA Med Ctr, Ctr Innovat Visual Rehabil, Boston, MA USA
[3] Smith Kettlewell Eye Res Inst, San Francisco, CA 94115 USA
[4] Acad Appl Optometry FFA, D-80335 Munich, Germany
[5] Univ Munich, Human Sci Ctr, GRP, Munich, Germany
关键词
ARM; contrast sensitivity; motion perception; temporal resolution; visual field;
D O I
10.1007/s00417-007-0641-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To investigate the characteristics of dynamic processing in the visual field of patients with age-related maculopathy (ARM) by measuring motion sensitivity, double-pulse resolution (DPR), and critical flicker fusion. Methods Fourteen subjects with ARM (18 eyes), 14 age-matched controls (19 eyes), and 7 young controls (8 eyes) served as subjects. Motion contrast thresholds were determined by a four-alternative forced-choice (4 afc) staircase procedure with a modification by Kernbach for presenting a plaid (size=3.8 degrees) moving within a stationary spatial and temporal Gaussian envelope in one of four directions. Measurements were performed on the horizontal meridian at 10 degrees, 20 degrees, 30 degrees, 40 degrees, and 60 degrees eccentricity. DPR was defined as the minimal temporal gap detectable by the subject using a 9-fold interleaved adaptive procedure, with stimuli positioned on concentric rings at 5 degrees, 10 degrees, and 20 degrees eccentricity on the principal and oblique meridians. Critical flicker fusion thresholds (CFF) and the Lanthony D-15 color vision test were applied foveally, and the subjects were free to use their fovea or whatever retinal area they needed to use instead, due to their retinal lesions caused by ARM. All measurements were performed under photopic conditions. Results Motion contrast sensitivity in subjects with ARM was pronouncedly reduced (0.23-0.66 log units, p < 0.01), not only in the macula but in a region up to 20 degrees eccentricity. In the two control groups, motion contrast sensitivity systematically declined with retinal eccentricity (0.009-0.032 log units/degree) and with age (0.01 log units/year). Double-pulse thresholds in healthy subjects were approximately constant in the central visual field and increased outside a radius of 10 degrees (1.73 ms/degree). DPR thresholds were elevated in subjects with ARM (by 23-32 ms, p < 0.01) up to 20 degrees eccentricity, and their foveal CFFs were increased by 5.5 Hz or 14% (p < 0.01) as compared with age-matched controls. Conclusions Dynamic processing properties in subjects with ARM are severely impaired in the central visual field up to 20 degrees eccentricity, which is clearly beyond the borders of the macula.
引用
收藏
页码:27 / 37
页数:11
相关论文
共 62 条
  • [1] ADAMS AJ, 1987, DIAGNOSIS MANAGEMENT
  • [2] ALM A, 2003, ADLERS PHYSL EYE, P319
  • [3] The importance of sustained attention for patients with maculopathies
    Altpeter, E
    Mackeben, M
    Trauzettel-Klosinski, S
    [J]. VISION RESEARCH, 2000, 40 (10-12) : 1539 - 1547
  • [4] Raster-scan cathode-ray tubes for vision research - Limits of resolution in space, time and intensity, and some solutions
    Bach, M
    Meigen, T
    Strasburger, H
    [J]. SPATIAL VISION, 1997, 10 (04): : 403 - 414
  • [5] A randomised controlled trial investigating the effect of nutritional supplementation on visual function in normal, and age-related macular disease affected eyes: design and methodology [ISRCTN78467674]
    Bartlett, Hannah
    Eperjesi, Frank
    [J]. NUTRITION JOURNAL, 2003, 2 (1)
  • [6] AN INTERNATIONAL CLASSIFICATION AND GRADING SYSTEM FOR AGE-RELATED MACULOPATHY AND AGE-RELATED MACULAR DEGENERATION
    BIRD, AEC
    BRESSLER, NM
    BRESSLER, SB
    CHISHOLM, IH
    COSCAS, G
    DAVIS, MD
    DEJONG, PTVM
    KLAVER, CCW
    KLEIN, BEK
    KLEIN, R
    MITCHELL, P
    SARKS, JP
    SARKS, SH
    SOURBANE, G
    TAYLOR, HR
    VINGERLING, JR
    [J]. SURVEY OF OPHTHALMOLOGY, 1995, 39 (05) : 367 - 374
  • [7] BRESSLER S, 1994, PRINCIPLES PRACTICE
  • [8] BRESSLER SB, 1994, PRINCIPLES PRACTICE, P826
  • [9] BROWN B, 1986, OPHTHAL PHYSL OPT, V6, P81, DOI 10.1111/j.1475-1313.1986.tb00704.x
  • [10] BROWN B, 1986, AM J OPTOM PHYS OPT, V63, P733