Influence of scattered radiation on Gafchromic EBT3

被引:0
作者
Gotanda, T. [1 ]
Katsuda, T. [2 ]
Kawasaki, A. [3 ]
Gotanda, R. [1 ]
Akagawa, T. [4 ]
Kuwano, T. [5 ]
Tanki, N. [2 ]
Kawaji, Y. [6 ]
Shimono, T. [6 ]
Yamamoto, K. [7 ]
Yabunaka, K. [8 ]
机构
[1] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Okayama, Japan
[2] Butsuryo Coll Osaka, Fac Hlth Sci, Osaka, Japan
[3] Natl Hosp Org Kyushu Med Ctr, Div Radiol Technol, Fukuoka, Fukuoka, Japan
[4] Tokushima Red Cross Hosp, Dept Radiol Technol, Tokushima, Japan
[5] Okayama Univ, Grad Sch Hlth Sci, Okayama, Japan
[6] Junshin Gakuen Univ, Fac Hlth Sci, Fukuoka, Fukuoka, Japan
[7] Osaka Ctr Canc & Cardiovasc Dis Prevent, Dept Radiol, Osaka, Japan
[8] Univ Tokyo, Grad Sch Med, Bunkyou Ku, Tokyo, Japan
来源
EMBEC & NBC 2017 | 2018年 / 65卷
关键词
Radiochromic film; Gafchromic EBT3; scattered radiation; RADIOCHROMIC FILM; PHANTOM; ENERGY;
D O I
10.1007/978-981-10-5122-7_259
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Gafchromic EBT3 (EBT3) is used as a radio chromic film in half-value layer (HVL) measurement methods, which are used to calculate the effective energy for QA and QC. HVL measurements using EBT3 display a precision of less than 5 % compared with the results of standard method with an ionization chamber (IC) dosimeter, and offer a simple procedure for determining the HVL consistently and quickly without the need for an IC. However, it is difficult to apply this technique because of the scattered radiation caused by the geometric layout of the X-ray computed tomography (CT) apparatus. In this study, the effect of scattered radiation on EBT3 is investigated. It was found that the EBT3 is not affected by scattered radiation at positions beyond 50 mm from the scattering substance. Therefore, the results suggest that EBT3 is suitable for use in Xray CT HVL measurements. On the other hand, when the distance from the scattering substance was 10 mm or less, EBT3 showed very high absorption compared to a semiconductor detector. Therefore, EBT3 is more sensitive than the semiconductor detector at a close range and can be used to measure scattered radiation when the distance from the scattering substance is 10 mm or less.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 9 条
[1]   Scanner uniformity improvements for radiochromic film analysis with matt reflectance backing [J].
Butson, Ethan ;
Alnawaf, Hani ;
Yu, Peter K. N. ;
Butson, Martin .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (03) :401-407
[2]   Computed tomography phantom for radiochromic film dosimetry [J].
Gotanda, R. ;
Katsuda, T. ;
Gotanda, T. ;
Eguchi, M. ;
Takewa, S. ;
Tabuchi, A. ;
Yatake, H. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (03) :194-199
[3]   Dose distribution in pediatric CT head examination using a new phantom with radiochromic film [J].
Gotanda, R. ;
Katsuda, T. ;
Gotanda, T. ;
Tabuchi, A. ;
Yatake, H. ;
Takeda, Y. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (04) :339-344
[4]   Energy response of the GAFCHROMIC EBT3 in diagnosis range [J].
Gotanda, T. ;
Katsuda, T. ;
Gotanda, R. ;
Kuwano, T. ;
Akagawa, T. ;
Tanki, N. ;
Tabuchi, A. ;
Shimono, T. ;
Kawaji, Y. ;
Ideguchi, T. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 :752-755
[5]   Evaluation of effective energy using radiochromic film and a step-shaped aluminum filter [J].
Gotanda, T. ;
Katsuda, T. ;
Gotanda, R. ;
Tabuchi, A. ;
Yamamoto, K. ;
Kuwano, T. ;
Yatake, H. ;
Kashiyama, K. ;
Yabunaka, K. ;
Akagawa, T. ;
Takeda, Y. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) :213-222
[6]   Half-value layer measurement: simple process method using radiochromic film [J].
Gotanda, T. ;
Katsuda, T. ;
Gotanda, R. ;
Tabuchi, A. ;
Yamamoto, K. ;
Kuwano, T. ;
Yatake, H. ;
Kashiyama, K. ;
Takeda, Y. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (03) :150-158
[7]   Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density [J].
Gotanda, T. ;
Katsuda, T. ;
Gotanda, R. ;
Tabuchi, A. ;
Yamamoto, K. ;
Kuwano, T. ;
Yatake, H. ;
Takeda, Y. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (01) :26-29
[8]   Effective energy measurement using radiochromic film: application of a mobile scanner [J].
Gotanda, Tatsuhiro ;
Katsuda, Toshizo ;
Gotanda, Rumi ;
Kuwano, Tadao ;
Akagawa, Takuya ;
Tanki, Nobuyoshi ;
Tabuchi, Akihiko ;
Shimono, Tetsunori ;
Kawaji, Yasuyuki ;
Takeda, Yoshihiro .
POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2016, 22 (04) :85-92
[9]   Evaluation of GAFCHROMIC EBT2 dosimetry for the low dose range using a flat-bed scanner with the reflection mode [J].
Gotanda, Tatsuhiro ;
Katsuda, Toshizo ;
Akagawa, Takuya ;
Gotanda, Rumi ;
Tabuchi, Akihiko ;
Yamamoto, Kenyu ;
Kuwano, Tadao ;
Yatake, Hidetoshi ;
Yabunaka, Koichi ;
Takeda, Yoshihiro .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (01) :59-63