Evaluation and Prediction of Flashover Voltage on Contaminated Composite Insulators

被引:0
|
作者
Kiruthika, M. [1 ]
Sivadasan, J. [1 ]
机构
[1] Natl Engn Coll, Dept EEE, Kovilpatti 628503, India
关键词
Silicon rubber; hydrophobicity; prediction; ESDD; insulator design; ANN; LS-SVM;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Insulators plays a vital role in electrical transmission line. It gives a support and separate electrical conductors and these insulators are most commonly made up of porcelain. These insulators gets polluted when they are placed near different atmospheric conditionlike coastal, desert etc. Now-a-days porcelain insulators are replaced by the silicon rubber insulators due its hydrophobicity property. The design parameters of silicon rubber insulator such as creepage factor, profile factor also contributes the pollution flashover. In order to assess the pollution severity level and to prevent the unpredictable flashover voltage, it is important to predict the flashover before it takes place. In this paper, four different types of 11 kV silicon rubber insulators were taken and solid layer method was used in artificial pollution test, in which sodium chloride and kaolin are used to induce the conductivity. Using even rising method, the flashover voltage has been obtained for different equivalent salt deposit density (ESDD) values. By using artificial neural network(ANN) and least square support vector machine (LS-SVM) flashover voltage has been predicted with the input parameters such as height, creepage length, diameter and ESDD. Finally, it is concluded that the LS-SVM approach has better ability to assist the flashover voltage prediction than ANN.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Flashover of Composite Insulators Induced by Bird Excretion
    Su, Huafeng
    Jia, Zhidong
    Guan, Zhicheng
    PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2013), VOLS 1 AND 2, 2013, : 166 - 169
  • [42] Experimental analysis of unidentified flashover for composite insulators
    Zhu, Yu
    Jiang, Xiu-Chen
    Gaoya Dianqi/High Voltage Apparatus, 2002, 38 (01):
  • [43] Voltage Distribution and Flashover Performance of 220 kV Composite Insulators under Different Icing Conditions
    Lu, Jiazheng
    Xie, Pengkang
    Jiang, Zhenglong
    Fang, Zhen
    Wu, Wei
    ENERGIES, 2018, 11 (03)
  • [44] FLASHOVER OF CONTAMINATED INSULATORS WITH CYLINDRICAL SYMMETRY UNDER DC CONDITIONS
    JOLLY, DC
    POOLE, CD
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1979, 14 (02): : 77 - 84
  • [45] FLASHOVER TEST AT PROJECT UHV ON SALT-CONTAMINATED INSULATORS
    KAWAI, M
    MILONE, DM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (05): : 755 - &
  • [46] Evaluation methods of contamination flashover voltage performance of semi-conducting glaze insulators
    Hayashi, Akio
    Yamada, Kazuma
    Saka, Chiharu
    Sakanishi, Kenji
    Matsuoka, Ryosuke
    CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 458 - 461
  • [47] Dynamic characters exploring of flashover arc for AC contaminated insulators
    He, Bo
    Lin, Hui
    Fu, Qiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2006, 26 (21): : 177 - 182
  • [48] CONTAMINATED INSULATORS - CHEMICAL DEPENDENCE OF FLASHOVER VOLTAGES AND SALT MIGRATION
    WILLIAMS, LJ
    KIM, JH
    KIM, YB
    ARAI, N
    SHIMODA, O
    HOLTE, KC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (05): : 1572 - 1580
  • [49] Effect of climatic conditions on contamination flashover voltage of insulators
    Mizuno, Y
    Kusada, H
    Naito, K
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1997, 4 (03) : 286 - 289
  • [50] Influence of nonsoluble contaminants on the flashover voltages of artificially contaminated insulators
    Matsuoka, R
    Kondo, K
    Naito, K
    Ishii, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 420 - 430