Potential low frequency ground vibration (< 6.3 Hz) impacts from underground LRT operations

被引:42
作者
Wolf, S [1 ]
机构
[1] Parsons Brinckerhoff, Orange, CA 92668 USA
关键词
D O I
10.1016/S0022-460X(03)00730-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vibration sensitive research activities at the laboratories of the University of Washington (UW) Physics and Astronomy Building (PAB) were a critical issue for the design of the Sound Transit Link Light Rail LRT system in Seattle, Washington. A study was conducted to measure and predict low frequency ground vibration generated by the LRT operations. The University's concern was an on-going research experiment in gravity, which had sensitivity to vibration below 6.3 Hz. The experiment was located on an independent concrete slab in an area cut-out from the building foundation with no connection to the building structure. Another concern was the planned future construction of a Life Sciences Center with vibration sensitive test equipment. This paper presents the results of a study to estimate the ground displacement at these buildings using empirical measured data of a similar deep tunnel transit system and finite difference modelling analysis. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:651 / 661
页数:11
相关论文
共 3 条
  • [1] MALONE S, 1999, SEISMIC NOISE MEASUR
  • [2] *SHANN WILS, 1999, UW LOW FREQ VIBR STU
  • [3] 1999, LOW FREQUENCY GROUND