Three-Axis Capacitive Sensor Arrays for Local and Global Shear Force Detection

被引:23
作者
Fernandes, Jayer [1 ]
Chen, Jiangang [1 ]
Jiang, Hongrui [2 ,3 ]
机构
[1] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Elect & Comp Engn, Dept Biomed Engn, Dept Mat Sci & Engn,Dept Ophthalmol & Visual Sci, Madison, WI 53706 USA
[3] Univ Wisconsin, McPherson Eye Res Inst, Madison, WI 53706 USA
关键词
Electrodes; Force; Dielectrics; Capacitance; Sensor arrays; Fabrication; Robot sensing systems; Flexible electronics; capacitive sensing; tactile sensing; shear force; normal force; dielectric; soft lithography; three-axis capacitive sensor; FLEXIBLE TACTILE SENSOR; PARKINSONS-DISEASE; STEP INITIATION; STRESS SENSOR; SENSING ARRAY; PRESSURE; SOCKET; LIMB;
D O I
10.1109/JMEMS.2021.3101735
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report the real time characterization and measurement results of a new tri-axial capacitive sensing array. Each unit cell of the Kapton based sensor has an overlapping electrode geometry that allows for the measurement of normal and shear force magnitudes, and the estimation of the 2D and 3D angle of the shear force. The use of a patterned Ecoflex dielectric layer further improves the shear force response and the tunability of the sensor. A custom readout circuit was developed to selectively read the differential capacitances in the sensor array. The local (unit cell) and global (array) force response of the sensor was characterized using a tilt stage, allowing us to determine both the normal and the shear response at different angles in the range of 0-20N. The results show that the Unit Cell response is uniform in the linear range of 0-10N for normal forces (4.6fF/N for all four differential capacitances) and shows good sensitivity for shear forces (1.4 fF/N difference between the right and left differential capacitances at the minimum) and low cross talk. Similar results were seen when a global force was applied across the sensor array. 2D and 3D models were developed to extrapolate the shear force angle from the capacitance data. We also characterized the flexible patterned dielectric layer to understand the effect of its structural dimensions on the effective relative permittivity and developed an analytical model to easily calculate the effective relative permittivity, which showed excellent correlation with the experimentally obtained results. [2020-0382]
引用
收藏
页码:799 / 813
页数:15
相关论文
共 47 条
[1]   A novel all-elastomer MEMS tactile sensor for high dynamic range shear and normal force sensing [J].
Charalambides, Alexi ;
Bergbreiter, Sarah .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2015, 25 (09)
[2]   Gait Disorders in Parkinson's Disease: Assessment and Management [J].
Chen, Pei-Hao ;
Wang, Rong-Long ;
Liou, De-Jyun ;
Shaw, Jin-Siang .
INTERNATIONAL JOURNAL OF GERONTOLOGY, 2013, 7 (04) :189-193
[3]   A Polymer-Based Capacitive Sensing Array for Normal and Shear Force Measurement [J].
Cheng, Ming-Yuan ;
Lin, Chun-Liang ;
Lai, Yu-Tse ;
Yang, Yao-Joe .
SENSORS, 2010, 10 (11) :10211-10225
[4]   Silicon three-axial tactile sensor [J].
Chu, Z ;
Sarro, PM ;
Middelhoek, S .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 54 (1-3) :505-510
[5]   Photopatternable conductive PDMS materials for microfabrication [J].
Cong, Hailin ;
Pan, Tingrui .
ADVANCED FUNCTIONAL MATERIALS, 2008, 18 (13) :1912-1921
[6]   Tactile Sensing-From Humans to Humanoids [J].
Dahiya, Ravinder S. ;
Metta, Giorgio ;
Valle, Maurizio ;
Sandini, Giulio .
IEEE TRANSACTIONS ON ROBOTICS, 2010, 26 (01) :1-20
[7]   The placebo effect in neurological disorders [J].
de la Fuente-Fernández, R ;
Schulzer, M ;
Stoessel, AJ .
LANCET NEUROLOGY, 2002, 1 (02) :85-91
[8]   Free-living monitoring of Parkinson's disease: Lessons from the field [J].
Del Din, Silvia ;
Godfrey, Alan ;
Mazza, Claudia ;
Lord, Sue ;
Rochester, Lynn .
MOVEMENT DISORDERS, 2016, 31 (09) :1293-1313
[9]   Development of polyimide flexible tactile sensor skin [J].
Engel, J ;
Chen, J ;
Liu, C .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (03) :359-366
[10]   Stretchable Complementary Split Ring Resonator (CSRR)-Based Radio Frequency (RF) Sensor for Strain Direction and Level Detection [J].
Eom, Seunghyun ;
Lim, Sungjoon .
SENSORS, 2016, 16 (10)