Modeling fomite-mediated SARS-CoV-2 exposure through personal protective equipment doffing in a hospital environment

被引:13
作者
King, Marco-Felipe [1 ]
Wilson, Amanda M. [2 ]
Weir, Mark H. [3 ]
Lopez-Garcia, Martin [4 ]
Proctor, Jessica [1 ]
Hiwar, Waseem [1 ]
Khan, Amirul [1 ]
Fletcher, Louise A. [1 ]
Sleigh, P. Andrew [1 ]
Clifton, Ian [5 ]
Dancer, Stephanie J. [6 ,7 ]
Wilcox, Mark [8 ,9 ]
Reynolds, Kelly A. [2 ]
Noakes, Catherine J. [1 ]
机构
[1] Univ Leeds, Sch Civil Engn, Woodhouse Lane, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Arizona, Dept Community Environm & Policy, Mel & Enid Zuckerman Coll Publ Hlth, Tucson, AZ USA
[3] Ohio State Univ, Div Environm Hlth Sci, Columbus, OH 43210 USA
[4] Univ Leeds, Sch Math, Leeds, W Yorkshire, England
[5] Univ Leeds, Dept Resp Med, St Jamess Hosp, Leeds, W Yorkshire, England
[6] Edinburgh Napier Univ, Sch Appl Sci, Edinburgh, Midlothian, Scotland
[7] Hairmyres Hosp, NHS Lanarkshire, Dept Microbiol, Glasgow G75 8RG, Lanark, Scotland
[8] Leeds Teaching Hosp NHS Trust, Healthcare Associated Infect Res Grp, Leeds, W Yorkshire, England
[9] Univ Leeds, Leeds, W Yorkshire, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
COVID-19; hospital infection model; PPE; quantitative microbial risk assessment; SARS CoV-2; surface-contact transmission; TRANSFER EFFICIENCY; HAND; CARE; CONTAMINATION; SINGLE; CORONAVIRUSES; RISK; TRANSMISSION; INFECTION; SURFACES;
D O I
10.1111/ina.12938
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Self-contamination during doffing of personal protective equipment (PPE) is a concern for healthcare workers (HCW) following SARS-CoV-2-positive patient care. Staff may subconsciously become contaminated through improper glove removal; so, quantifying this exposure is critical for safe working procedures. HCW surface contact sequences on a respiratory ward were modeled using a discrete-time Markov chain for: IV-drip care, blood pressure monitoring, and doctors' rounds. Accretion of viral RNA on gloves during care was modeled using a stochastic recurrence relation. In the simulation, the HCW then doffed PPE and contaminated themselves in a fraction of cases based on increasing caseload. A parametric study was conducted to analyze the effect of: (1a) increasing patient numbers on the ward, (1b) the proportion of COVID-19 cases, (2) the length of a shift, and (3) the probability of touching contaminated PPE. The driving factors for the exposure were surface contamination and the number of surface contacts. The results simulate generally low viral exposures in most of the scenarios considered including on 100% COVID-19 positive wards, although this is where the highest self-inoculated dose is likely to occur with median 0.0305 viruses (95% CI =0-0.6 viruses). Dose correlates highly with surface contamination showing that this can be a determining factor for the exposure. The infection risk resulting from the exposure is challenging to estimate, as it will be influenced by the factors such as virus variant and vaccination rates.
引用
收藏
页数:12
相关论文
共 55 条
  • [11] Assessing Viral Transfer During Doffing of Ebola-Level Personal Protective Equipment in a Biocontainment Unit
    Casanova, Lisa M.
    Erukunuakpor, Kimberly
    Kraft, Colleen S.
    Mumma, Joel M.
    Durso, Francis T.
    Ferguson, Ashley N.
    Gipson, Christina L.
    Walsh, Victoria L.
    Zimring, Craig
    DuBose, Jennifer
    Jacob, Jesse T.
    [J]. CLINICAL INFECTIOUS DISEASES, 2018, 66 (06) : 945 - 949
  • [12] CDC, 2020, COR DIS 2019 COVID 1
  • [13] Efficacy of handrubbing with alcohol based solution versus standard handwashing with antiseptic soap: randomised clinical trial
    Girou, E
    Loyeau, S
    Legrand, P
    Oppein, F
    Brun-Buisson, C
    [J]. BRITISH MEDICAL JOURNAL, 2002, 325 (7360): : 362 - 365
  • [14] Aerosol and Surface Distribution of Severe Acute Respiratory Syndrome Coronavirus 2 in Hospital Wards, Wuhan, China, 2020
    Guo, Zhen-Dong
    Wang, Zhong-Yi
    Zhang, Shou-Feng
    Li, Xiao
    Li, Lin
    Li, Chao
    Cui, Yan
    Fu, Rui-Bin
    Dong, Yun-Zhu
    Chi, Xiang-Yang
    Zhang, Meng-Yao
    Liu, Kun
    Cao, Cheng
    Liu, Bin
    Zhang, Ke
    Gao, Yu-Wei
    Lu, Bing
    Chen, Wei
    [J]. EMERGING INFECTIOUS DISEASES, 2020, 26 (07) : 1586 - 1591
  • [15] Harbourt DE., 2020, PLOS NEGL TROP DIS, V14, pe0008831, DOI [10.1371/journal.pntd.0008831, DOI 10.1371/JOURNAL.PNTD.0008831]
  • [16] Microbial Assessment of High-, Medium-, and Low-Touch Hospital Room Surfaces
    Huslage, Kirk
    Rutala, William A.
    Gergen, Maria F.
    Sickbert-Bennett, Emily E.
    Weber, David J.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (02) : 211 - 212
  • [17] Interaction of healthcare worker hands and portable medical equipment: a sequence analysis to show potential transmission opportunities
    Jinadatha, Chetan
    Villamaria, Frank C.
    Coppin, John D.
    Dale, Charles R.
    Williams, Marjory D.
    Whitworth, Ryan
    Stibich, Mark
    [J]. BMC INFECTIOUS DISEASES, 2017, 17
  • [18] Johns Hopkins University, COVID 19 DASHB CTR S
  • [19] A Model of Exposure to Rotavirus from Nondietary Ingestion Iterated by Simulated Intermittent Contacts
    Julian, Timothy R.
    Canales, Robert A.
    Leckie, James O.
    Boehm, Alexandria B.
    [J]. RISK ANALYSIS, 2009, 29 (05) : 617 - 632
  • [20] Persistence of coronaviruses on inanimate surfaces and their inactivation with biocidal agents
    Kampf, G.
    Todt, D.
    Pfaender, S.
    Steinmann, E.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2020, 104 (03) : 246 - 251