A Stretchable Microneedle Electrode Array for Stimulating and Measuring Intramuscular Electromyographic Activity

被引:35
作者
Guvanasen, Gareth S. [1 ,2 ]
Guo, Liang [1 ,2 ]
Aguilar, Ricardo J. [3 ]
Cheek, Ashton L. [5 ]
Shafor, Chancellor S. [4 ]
Rajaraman, Swaminathan [6 ,7 ]
Nichols, T. Richard [8 ]
DeWeerth, Stephen P. [9 ,10 ]
机构
[1] Ohio State Univ, Dept Elect & Comp Engn, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Neurosci, Columbus, OH 43210 USA
[3] Axion BioSyst, MEMS Team, Atlanta, GA 30309 USA
[4] Axion BioSyst, Atlanta, GA 30309 USA
[5] Georgia Inst Technol, Dept Biomed Engn, Atlanta, GA 30332 USA
[6] Univ Cent Florida, NanoSci Technol Ctr, Orlando, FL 32816 USA
[7] Univ Cent Florida, Int Consortium Adv Mfg Res, Orlando, FL 32816 USA
[8] Georgia Inst Technol, Sch Biol Sci, Atlanta, GA 30332 USA
[9] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[10] Lehigh Univ, PC Rossin Coll Engn & Appl Sci, Bethlehem, PA 18015 USA
基金
美国国家卫生研究院;
关键词
Electromyography; multielectrode array; muscle; penetrating electrodes; stretchable; LATERAL GASTROCNEMIUS-MUSCLE; ELECTRICAL-STIMULATION; UNRESTRAINED LOCOMOTION; MICROELECTRODE ARRAY; CROSS-TALK; SURFACE; CAT; POLYDIMETHYLSILOXANE; CYTOTOXICITY; COMPARTMENTS;
D O I
10.1109/TNSRE.2016.2629461
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a stretchable microneedle electrode array (sMEA) to stimulate and measure the electrical activity of muscle across multiple sites. The technology provides the signal fidelity and spatial resolution of intramuscular electrodes across a large area of tissue. Our sMEA is composed of a polydimethylsiloxane ( PDMS) substrate, conductive-PDMS traces, and stainless-steel penetrating electrodes. The traces and microneedles maintain a resistance of less than 10 k Omega when stretched up to a similar to 63% tensile strain, which allows for the full range of physiological motion of feline muscle. The device and its constituent materials are cytocompatible for at least 28 days in vivo. When implanted in vivo, the device measures electromyographic (EMG) activity with clear compound motor unit action potentials. The sMEA also maintains a stable connection with moving muscle while electrically stimulating the tissue. This technology has direct application to wearable sensors, neuroprostheses, and electrophysiological studies of animals and humans.
引用
收藏
页码:1440 / 1452
页数:13
相关论文
共 68 条
[1]   Novel PDMS(silicone)-in-PDMS(silicone): Low Cost Flexible Electronics without Metallization [J].
Agar, Joshua C. ;
Lin, Katy J. ;
Zhang, Rongwei ;
Durden, Jessica ;
Moon, Kyoung-Sik ;
Wong, C. P. .
2010 PROCEEDINGS 60TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2010, :1226-1230
[2]  
[Anonymous], 1999, 12478 MSDS
[3]   Single-unit neural recording with active microelectrode arrays [J].
Bai, Q ;
Wise, KD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (08) :911-920
[4]   Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane:: A review [J].
Bélanger, MC ;
Marois, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :467-477
[5]   Electrophysiological studies of face perception in humans [J].
Bentin, S ;
Allison, T ;
Puce, A ;
Perez, E ;
McCarthy, G .
JOURNAL OF COGNITIVE NEUROSCIENCE, 1996, 8 (06) :551-565
[6]   Improvement in glycemic control by gastric electrical stimulation (TANTALUSTM) in overweight subjects with type 2 diabetes [J].
Bohdjalian, A. ;
Ludvik, B. ;
Guerci, B. ;
Bresler, L. ;
Renard, E. ;
Nocca, D. ;
Karnieli, E. ;
Assalia, A. ;
Prager, R. ;
Prager, G. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (09) :1955-1960
[7]   Long-term survival after pacemaker implantation - Prognostic importance of gender and baseline patient characteristics [J].
Brunner, M ;
Olschewski, M ;
Geibel, A ;
Bode, C ;
Zehender, M .
EUROPEAN HEART JOURNAL, 2004, 25 (01) :88-95
[8]   Ageing of natural rubber under stress [J].
Clarke, SM ;
Elias, F ;
Terentjev, EM .
EUROPEAN PHYSICAL JOURNAL E, 2000, 2 (04) :335-341
[9]   Cytotoxicity of copper ions released from metal - Variation with the exposure period and concentration gradients [J].
Cortizo, MC ;
De Mele, MFL .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2004, 102 (1-3) :129-141
[10]   THE USE OF ATP BIOLUMINESCENCE AS A MEASURE OF CELL-PROLIFERATION AND CYTOTOXICITY [J].
CROUCH, SPM ;
KOZLOWSKI, R ;
SLATER, KJ ;
FLETCHER, J .
JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 160 (01) :81-88