Design optimization and experimental evaluation of photovoltaic double skin facade

被引:23
作者
Lee, Chul-sung [1 ]
Lee, Hyomun [2 ]
Choi, Minjoo [2 ]
Yoon, Jongho [2 ]
机构
[1] Rural Res Inst, Future Agr Div, 870 Haean Ro, Ansan 15634, Gyeonggi Do, South Korea
[2] Hanbat Natl Univ, Dept Architectural Engn, San 16-1 Duckmyung Dong, Daejeon 34158, South Korea
基金
新加坡国家研究基金会;
关键词
Design optimization; Photovoltaic double skin facade (PV-DSF); Photovoltaic vent window; Optimal operating angle; Heating and cooling energy consumption; ENERGY PERFORMANCE; SENSITIVITY-ANALYSIS; PERSPECTIVES; BUILDINGS; SYSTEMS; PANELS;
D O I
10.1016/j.enbuild.2019.07.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposed the introduction of a photovoltaic double skin facade (PV-DSF) as a way to economically and easily improve the performance of building envelopes. This system has been designed to be installed not only in new buildings but also in remodeling or renovation projects of existing buildings even in a state where occupants are present inside. For the PV-DSF system suggested, this study aimed to perform experimental evaluation of 1) the optimal operation method to maximize electric energy production of the PV vent window and to reduce the heating and cooling energy consumption of buildings and 2) the thermal behavior and energy performance of the building when the proposed PV-DSF is applied. Analysis results using simulation have shown that the monthly optimal operating angles of the PV vent window to minimize heating and cooling energy demand were the same as the operating angles to maximize power generation. It has also been proven through experiments that the proper operation of the PV vent window can significantly reduce the energy demand of buildings. In particular, the difference between the DSF and outdoor temperatures was 12 degrees C in winter, showing that it is possible to achieve a significant reduction of heating energy demand. Lastly, when the PV-DSF was applied, air and wall temperatures were decreased by 0.5 degrees C and 2 degrees C in summer, respectively, and cooling energy consumption was also at least 10% reduced on average. (c) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 36 条
[1]  
[Anonymous], 2012, SOL ENERGY MAT SOL C
[2]   Perspectives of double skin facades for naturally ventilated buildings: A review [J].
Barbosa, Sabrina ;
Ip, Kenneth .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 :1019-1029
[3]   Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis [J].
Breesch, H. ;
Janssens, A. .
SOLAR ENERGY, 2010, 84 (08) :1453-1467
[4]   Thermal regulation of photovoltaic cladding [J].
Brinkworth, BJ ;
Cross, BM ;
Marshall, RH ;
Yang, HX .
SOLAR ENERGY, 1997, 61 (03) :169-178
[5]   Uncertainties and sensitivity analysis in building energy simulation using macroparameters [J].
Calleja Rodriguez, Gloria ;
Carrillo Andres, Antonio ;
Dominguez Munoz, Fernando ;
Cejudo Lopez, Jose Manuel ;
Zhang, Yi .
ENERGY AND BUILDINGS, 2013, 67 :79-87
[6]   Investigation on energy performance of double skin facade in Hong Kong [J].
Chan, A. L. S. ;
Chow, T. T. ;
Fong, K. F. ;
Lin, Z. .
ENERGY AND BUILDINGS, 2009, 41 (11) :1135-1142
[7]   Optimization of the performance of double-facades with integrated photovoltaic panels and motorized blinds [J].
Charron, Remi ;
Athienitis, Andreas K. .
SOLAR ENERGY, 2006, 80 (05) :482-491
[8]   Numerical analysis of the most appropriate heat transfer correlations for free ventilated double skin photovoltaic facades [J].
Cipriano, Jordi ;
Houzeaux, Guillaume ;
Chemisana, Daniel ;
Lodi, Chiara ;
Marti-Herrero, Jaime .
APPLIED THERMAL ENGINEERING, 2013, 57 (1-2) :57-68
[9]   Uncertainty and Sensitivity Analysis for Building Energy Rating [J].
Corrado, Vincenzo ;
Mechri, Houcem Eddine .
JOURNAL OF BUILDING PHYSICS, 2009, 33 (02) :125-156