Mathematical modelling of a dual-fluid concentrating photovoltaic-thermal (PV-T) solar collector

被引:28
作者
Baljit, S. S. S. [1 ]
Chan, H. -Y. [1 ]
Audwinto, V. A. [1 ]
Hamid, S. A. [1 ]
Fudholi, Ahmad [1 ]
Zaidi, S. H. [1 ]
Othman, M. Y. [2 ]
Sopian, K. [1 ]
机构
[1] Univ Kebangsaan Malaysia, SERI, Bangi 43600, Selangor, Malaysia
[2] Univ Kebangsaan Malaysia, Inst Islam Hadhari, Bangi 43600, Selangor, Malaysia
关键词
Photovoltaic-thermal collector; Dual fluids; Mathematical model; Fresnel lens; Compound parabolic concentrators; HYBRID COLLECTOR; AIR COLLECTOR; PERFORMANCE; SYSTEMS;
D O I
10.1016/j.renene.2017.08.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents an improved photovoltaic-thermal (PV-T) solar collector system that integrates a PV panel with a serpentine-flow stainless steel tube as the water-heating component and a double pass air channel as the air-heating component. A Fresnel lens is used as the glazing and primary concentrator, and compound parabolic concentrators (CPCs) are used as the secondary concentrator. The system can simultaneously generate hot air and hot water in addition to electricity, and the total energy generated per unit area is higher than that of a single-fluid system. This triple-function PV-T solar collector is well suited for a wide range of thermal applications and offers options for hot and/or cold air and water use depending on the application and energy needs. This paper establishes, develops, and validates a conceptual design for a concentrating PV-T dual-fluid solar collector with 1D steady-state energy-balance equations for the dual-fluid (air and water) configuration. Next, this model is used to predict the performance of the dual-fluid solar collector with varying air and water mass flow rates. Then, the simulation results of the single- and dual-fluid operational modes are compared. The simulated results have shown that the total equivalent efficiencies for single fluid condition have ranged from approximately 30 to 60%, and increased to a maximum efficiency of near to 90% for the case of the dual fluids. The dual fluids operation mode has reduced the solar cells temperature and hence increased the electrical output. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1258 / 1271
页数:14
相关论文
共 32 条
[1]   Design concept and mathematical model of a bi-fluid photovoltaic/thermal (PV/T) solar collector [J].
Abu Bakar, Mohd Nazari ;
Othman, Mahmod ;
Din, Mahadzir Hj ;
Manaf, Norain A. ;
Jarimi, Hasila .
RENEWABLE ENERGY, 2014, 67 :153-164
[2]   Field study of various air based photovoltaic/thermal hybrid solar collectors [J].
Amori, Karima E. ;
Abd-AlRaheem, Mustafa Adil .
RENEWABLE ENERGY, 2014, 63 :402-414
[3]   A thermal model for photovoltaic panels under varying atmospheric conditions [J].
Armstrong, S. ;
Hurley, W. G. .
APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) :1488-1495
[4]   Study of a new concept of photovoltaic-thermal hybrid collector [J].
Assoa, Y. B. ;
Menezo, C. ;
Fraisse, G. ;
Yezou, R. ;
Brau, J. .
SOLAR ENERGY, 2007, 81 (09) :1132-1143
[5]   Dynamic study of a new concept of photovoltaic thermal hybrid collector [J].
Assoa, Y. B. ;
Menezo, C. .
SOLAR ENERGY, 2014, 107 :637-652
[6]  
Bergman T.L., 2011, Introduction to Heat Transfer, DOI DOI 10.1016/J.APPLTHERMALENG.2011.03.022
[7]  
Duffle J. A., 2003, SOLAR ENG THERMAL PR
[8]   Study of the thermal and electrical performances of PVT solar hot water system [J].
Dupeyrat, P. ;
Menezo, C. ;
Fortuin, S. .
ENERGY AND BUILDINGS, 2014, 68 :751-755
[9]   EXTENSION OF THE HOTTEL-WHILLIER MODEL TO THE ANALYSIS OF COMBINED PHOTOVOLTAIC THERMAL FLAT-PLATE COLLECTORS [J].
FLORSCHUETZ, LW .
SOLAR ENERGY, 1979, 22 (04) :361-366
[10]   Performance analysis of photovoltaic thermal (PVT) water collectors [J].
Fudholi, Ahmad ;
Sopian, Kamaruzzaman ;
Yazdi, Mohammad H. ;
Ruslan, Mohd Hafidz ;
Ibrahim, Adnan ;
Kazem, Hussein A. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 78 :641-651