A prospective investigation of fluorescence imaging to detect sentinel lymph nodes at robotic-assisted endometrial cancer staging

被引:54
|
作者
Paley, Pamela J. [1 ]
Veljovich, Dan S. [1 ]
Press, Joshua Z. [1 ]
Isacson, Christina [2 ]
Pizer, Ellen [2 ]
Shah, Chirag [1 ]
机构
[1] Pacific Gynecol Specialists, Div Gynecol Oncol, Seattle, WA USA
[2] CellNetix Pathol & Labs, Seattle, WA USA
关键词
endometrial carcinoma; robotic surgery; sentinel node mapping; GYNECOLOGIC-ONCOLOGY-GROUP; INDOCYANINE GREEN; NODAL METASTASIS; BREAST-CANCER; ASTEC TRIAL; LYMPHADENECTOMY; MULTICENTER; MALIGNANCIES; DISSECTION; MORBIDITY;
D O I
10.1016/j.ajog.2015.12.046
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: The accuracy of sentinel lymph node mapping has been shown in endometrial cancer, but studies to date have primarily focused on cohorts at low risk for nodal involvement. In our practice, we acknowledge the lack of benefit of lymphadenectomy in the low-risk subgroup and omit lymph node removal in these patients. Thus, our aim was to evaluate the feasibility and accuracy of sentinel node mapping in women at sufficient risk for nodal metastasis warranting lymphadenectomy and in whom the potential benefit of avoiding nodal procurement could be realized. OBJECTIVE: To evaluate the detection rate and accuracy of fluorescence-guided sentinel lymph node mapping in endometrial cancer patients undergoing robotic-assisted staging. STUDY DESIGN: One hundred twenty-three endometrial cancer patients undergoing sentinel lymph node sentinel node mapping using indocyanine green were prospectively evaluated. Two mL (1.0 mg/mL) of dye were injected into the cervical stroma divided between the 2-3 and 9-10 o'clock positions at the time of uterine manipulator placement. Before hysterectomy, the retroperitoneal spaces were developed and fluorescence imaging was used for sentinel node detection. Identified sentinel nodes were removed and submitted for touch prep intraoperatively, followed by permanent assessment with routine hematoxylin and eosin levels. Patients then underwent hysterectomy, bilateral salpingo-oophorectomy, and completion bilateral pelvic and periaortic lymphadenectomy based on intrauterine risk factors determined intraoperatively (tumor size >2 cm, >50% myometrial invasion, and grade 3 histology). RESULTS: Of 123 patients enrolled, at least 1 sentinel node was detected in 119 (96.7%). Ninety-nine patients (80%) had bilateral pelvic or periaortic sentinel nodes detected. A total of 85 patients met criteria warranting completion lymphadenectomy. In 14 patients (16%) periaortic lymphadenectomy was not feasible, and the mean number of pelvic nodes procured was 13 (6 -22). Of the 71 patients undergoing pelvic and periaortic lymphadenectomy, the mean nodal count was 23.2 (8 - 51). Of patients undergoing lymphadenectomy, 10.6% had lymph node metastasis on final hematoxylin and eosin evaluation. Notably, the sentinel node was the only positive node in 44% of cases. There were no cases in which final pathology of the sentinel node was negative and metastatic disease was detected upon completion lymphadenectomy in the non-sentinel nodes (no false negatives), yielding a sensitivity of 100%. Of the 14 sentinel nodes ultimately found to harbor metastases, 3 were negative on touch prep, yielding a sensitivity of 78.6% for intraoperative detection of sentinel node involvement. In all 3 of the false-negative touch preps, final pathology detected a single micrometastasis (0.24 mm, 1.4 mm, 1.5 mm). As expected, there were no false-positive results, yielding a specificity of 100%. No complications related to sentinel node mapping or allergic reactions to the dye were encountered. CONCLUSION: Intraoperative sentinel node mapping using fluorescence imaging with indocyanine green in endometrial cancer patients is feasible and yields high detection rates. In our pilot study, sentinel node mapping identified all women with Stage IIIC disease. Low false-negative rates are encouraging, and if confirmed in multi-institutional trials, this approach would be anticipated to reduce the morbidity, operative times, and costs associated with complete pelvic and periaortic lymphadenectomy.
引用
收藏
页码:117.e1 / 117.e7
页数:7
相关论文
共 50 条
  • [31] Robotic-Assisted Sentinel Lymph Node Mapping With Indocyanine Green in Pelvic Malignancies: A Systematic Review and Meta-Analysis
    Wu, Yuqing
    Jing, Jibo
    Wang, Jinfeng
    Xu, Bin
    Du, Mulong
    Chen, Ming
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [32] Validation of Sentinel Lymph Node Biopsy in Robotic Endometrial Cancer Staging Surgery: Results From a High-Volume Center in India
    Roy, Arunava
    Rout, Subhashree
    Bhaumik, Jaydip
    JCO GLOBAL ONCOLOGY, 2023, 9 : e2200347
  • [33] Sentinel lymph node mapping and staging in endometrial cancer: A Society of Gynecologic Oncology literature review with consensus recommendations
    Holloway, Robert W.
    Abu-Rustum, Nadeem R.
    Backes, Floor J.
    Boggess, John F.
    Gotlieb, Walter H.
    Lowery, W. Jeffrey
    Rossi, Emma C.
    Tanner, Edward J.
    Wolsky, Rebecca J.
    GYNECOLOGIC ONCOLOGY, 2017, 146 (02) : 405 - 415
  • [34] Endometrial and cervical cancer patients with multiple sentinel lymph nodes at laparoscopic ICG mapping: How many are enough?
    Papadia, Andrea
    Imboden, Sara
    Gasparri, Maria Luisa
    Siegenthaler, Franziska
    Fink, Anja
    Mueller, Michael D.
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2016, 142 (08) : 1831 - 1836
  • [35] A Comparison of the Detection of Sentinel Lymph Nodes Using Indocyanine Green and Near-Infrared Fluorescence Imaging Versus Blue Dye During Robotic Surgery in Uterine Cancer
    Eriksson, Ane Gerda
    Beavis, Anna
    Soslow, Robert A.
    Zhou, Qin
    Abu-Rustum, Nadeem R.
    Gardner, Ginger J.
    Zivanovic, Oliver
    Roche, Kara Long
    Sonoda, Yukio
    Leitao, Mario M., Jr.
    Jewell, Elizabeth L.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2017, 27 (04) : 743 - 747
  • [36] Fluorescence imaging to study cancer burden on lymph nodes
    D'Souza, Alisha V.
    Elliott, Jonathan T.
    Gunn, Jason R.
    Samkoe, Kimberley S.
    Tichauer, Kenneth M.
    Pogue, Brian W.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [37] An Extraordinary Location of Sentinel Lymph Nodes in a Patient with Endometrial Cancer
    Comba, Cihan
    Aslan, Erkan
    Vatankulu, Betul
    Tatar, Zeynep
    Demir, Ali Aslan
    Demir, Omer
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2023, 30 (08) : 613 - 614
  • [38] Detection of micrometastases in the sentinel lymph nodes of patients with endometrial cancer
    Niikura, Hitoshi
    Okamoto, Satoshi
    Yoshinaga, Kosuke
    Nagase, Satoru
    Takano, Tadao
    Ito, Kiyoshi
    Yaegashi, Nobuo
    GYNECOLOGIC ONCOLOGY, 2007, 105 (03) : 683 - 686
  • [39] Intraoperative identification of sentinel lymph nodes by near-infrared fluorescence imaging in patients with breast cancer
    Tagaya, Nobumi
    Yamazaki, Rie
    Nakagawa, Aya
    Abe, Akihito
    Hamada, Kiyoshige
    Kubota, Keiichi
    Oyama, Tetsunari
    AMERICAN JOURNAL OF SURGERY, 2008, 195 (06): : 850 - 853
  • [40] A Prospective Cohort Study Comparing Colorimetric and Fluorescent Imaging for Sentinel Lymph Node Mapping in Endometrial Cancer
    Holloway, Robert W.
    Ahmad, Sarfraz
    Kendrick, James E.
    Bigsby, Glenn E.
    Brudie, Lorna A.
    Ghurani, Giselle B.
    Stavitzski, Nicole M.
    Gise, Jasmine L.
    Ingersoll, Susan B.
    Pepe, Julie W.
    ANNALS OF SURGICAL ONCOLOGY, 2017, 24 (07) : 1972 - 1979