Thermal characteristics in round tube fitted with serrated twisted tape

被引:180
|
作者
Eiamsa-ard, Smith [1 ]
Promvonge, Pongjet [2 ]
机构
[1] Mahanakorn Univ Technol, Fac Engn, Dept Mech Engn, Bangkok 10530, Thailand
[2] King Mongkuts Inst Technol Ladkrabang, Fac Engn, Sch Mech Engn, Bangkok 10520, Thailand
关键词
Heat transfer; Friction factor; Serrated twisted tape; Typical twisted tape; Swirl flow; FRICTION FACTOR CHARACTERISTICS; HEAT-TRANSFER CHARACTERISTICS; PRESSURE-DROP; LAMINAR-FLOW; CONICAL-RING; ENHANCEMENT;
D O I
10.1016/j.applthermaleng.2010.03.026
中图分类号
O414.1 [热力学];
学科分类号
摘要
The article presents an investigation of the effect of twisted tape with serrated-edge insert on heat transfer and pressure loss behaviors in a constant heat-fluxed tube. In the experiments, the serrated twisted tape (STT) was inserted into the entire test tube with a constant twist ratio in order to generate a continuous swirling airflow. Two geometry parameters of the STT to be considered in the present work are the serration width ratio and the serration depth ratio. The measurements have been conducted for the airflow rate based on Reynolds numbers in the turbulent regime from 4000 to 20,000. The experimental results of the STT inserted tube are compared with those of the plain tube fitted with typical twisted tape (TT). The results show that the heat transfer rate in terms of Nusselt number, No increases with the rise in the depth ratio but decreases with raising the width ratio. The heat transfer rate is up to 72.2% and 27% relative to the plain tube and the TT inserted tube, respectively. The use of the STT leads to higher heat transfer rate and friction factor than that of the TT for all cases. The thermal performance factor of the STT tube under constant pumping power is evaluated and found to be above unity indicating that using the STT tube is advantageous over the TT tube or the plain tube. In addition, the empirical correlations developed by relating the serration width ratio, serration depth ratio and Reynolds number are determined. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1673 / 1682
页数:10
相关论文
共 50 条
  • [41] Enhancement of turbulent thermal convection in a circular tube with a slotted twisted tape
    Perng, Shiang-Wuu
    Wu, Horng Wen
    Kelana, Nugroho Putra
    Guo, Yi-Ling
    Yang, Chen-Jui
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2023, 33 (02) : 825 - 848
  • [42] Influence of twisted tape length on the thermal performance of a heat exchanger tube
    Panda, Jyoti Prakash
    Kumar, Bipin
    Kumar, Manoj
    Patil, Anil Kumar
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2023, 83 (06) : 650 - 663
  • [43] Influence of sawtooth twisted tape on thermal enhancement of heat exchanger tube
    Samutpraphut, Boonsong
    Eiamsa-ard, Smith
    Chuwattanakul, Varesa
    Thianpong, Chinaruk
    Maruyama, Naoki
    Hirota, Masafumi
    ENERGY REPORTS, 2023, 9 : 696 - 703
  • [44] PHOTOGRAPHIC STUDIES ON FLOW OF GAS-LIQUID MIXTURES THROUGH A VERTICAL TUBE FITTED WITH A TWISTED TAPE
    NOORUDDIN, AF
    MURTI, PS
    INDIAN JOURNAL OF TECHNOLOGY, 1973, 11 (09): : 377 - 380
  • [45] Investigation of heat exchanger tube fitted with triangular perforated nail head twisted-tape inserts
    Singh, Mohan
    Kumar, Amit
    Kumar, Arun
    HEAT TRANSFER, 2024, 53 (06) : 3157 - 3178
  • [46] Thermal analysis of v-cut twisted tape fitted heat exchanger: A numerical approach
    Kapade, Tushar T.
    Shah, Sanjay K.
    Shah, Dhruvian S.
    Kumar, N. Suresh
    Bhor, Janardhan K.
    Panwar, Vikas S.
    Singh, Gurbhej
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2025, 19 (03): : 1895 - 1911
  • [47] Turbulent heat transfer in a tube fitted with serrated twist tape under rolling and pitching environments with applications to shipping machineries
    Chang, Shyy Woei
    Liou, Tong-Miin
    Liou, Jin Shuen
    Chen, Kun-Tse
    OCEAN ENGINEERING, 2008, 35 (16) : 1569 - 1577
  • [48] Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Promvonge, Pongjet
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2006, 33 (10) : 1225 - 1233
  • [49] Numerical investigation and multi-criteria optimization of the thermal–hydraulic characteristics of turbulent flow in conical tubes fitted with twisted tape insert
    Muhammed A. Hassan
    Mahmoud A. Kassem
    Amr Kaood
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 6847 - 6868
  • [50] Heat Transfer and Pressure Drop in a Circular Tube Fitted with Twisted Tape Insert Having Continuous Cut Edges
    Sarviya, R. M.
    Fuskele, Veeresh
    JOURNAL OF ENERGY STORAGE, 2018, 19 : 10 - 14