Leaf trajectory calculation for dynamic multileaf collimation to realize optimized fluence profiles

被引:51
作者
Dirkx, MLP [1 ]
Heijmen, BJM [1 ]
van Santvoort, JPC [1 ]
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, NL-3075 EA Rotterdam, Netherlands
关键词
D O I
10.1088/0031-9155/43/5/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An algorithm for the calculation of the required leaf trajectories to generate optimized intensity modulated beam profiles by means of dynamic multileaf collimation is presented. This algorithm iteratively accounts for leaf transmission and collimator scatter and fully avoids tongue-and-groove underdosage effects. Tests on a large number of intensity modulated fields show that only a limited number of iterations, generally less than 10, are necessary to minimize the differences between optimized and realized fluence profiles. To assess the accuracy of the algorithm in combination with the dose calculation algorithm of the Cadplan 3D treatment planning system, predicted absolute dose distributions for optimized fluence profiles were compared with dose distributions measured on the MM50 Racetrack Microtron and resulting from the calculated leaf trajectories. Both theoretical and clinical cases yield an agreement within 2%, or within 2 mm in regions with a high dose gradient, showing that the accuracy is adequate for clinical application.
引用
收藏
页码:1171 / 1184
页数:14
相关论文
共 33 条
  • [1] METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY
    BORTFELD, T
    BURKELBACH, J
    BOESECKE, R
    SCHLEGEL, W
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) : 1423 - 1434
  • [2] X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS
    BORTFELD, TR
    KAHLER, DL
    WALDRON, TJ
    BOYER, AL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03): : 723 - 730
  • [3] OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES
    BRAHME, A
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) : 129 - 140
  • [4] DOSE CALCULATION FOR PHOTON BEAMS WITH INTENSITY MODULATION GENERATED BY DYNAMIC JAW OR MULTILEAF COLLIMATIONS
    CHUI, CS
    LOSASSO, T
    SPIROU, S
    [J]. MEDICAL PHYSICS, 1994, 21 (08) : 1237 - 1244
  • [5] Field margin reduction using intensity-modulated x-ray beams formed with a multileaf collimator
    Dirkx, MLP
    Heijmen, BJM
    Korevaar, GA
    vanOs, MJH
    Stroom, JC
    Koper, PCM
    Levendag, PC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05): : 1123 - 1129
  • [6] DAILY DOSIMETRIC QUALITY-CONTROL OF THE MM50 RACETRACK MICROTRON USING AN ELECTRONIC PORTAL IMAGING DEVICE
    DIRKX, MLP
    KROONWIJK, M
    DEBOER, JCJ
    HEIJMEN, BJM
    [J]. RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) : 55 - 60
  • [7] COMBINING MULTILEAF FIELDS TO MODULATE FLUENCE DISTRIBUTIONS
    GALVIN, JM
    CHEN, XG
    SMITH, RM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (03): : 697 - 705
  • [8] SIMULTANEOUS-OPTIMIZATION OF DYNAMIC MULTILEAF COLLIMATION AND SCANNING PATTERNS OR COMPENSATION FILTERS USING A GENERALIZED PENCIL BEAM ALGORITHM
    GUSTAFSSON, A
    LIND, BK
    SVENSSON, R
    BRAHME, A
    [J]. MEDICAL PHYSICS, 1995, 22 (07) : 1141 - 1156
  • [9] THE EFFECT OF COLLIMATOR BACKSCATTER RADIATION ON PHOTON OUTPUT OF LINEAR ACCELERATORS
    HUANG, PH
    CHU, J
    BJARNGARD, BE
    [J]. MEDICAL PHYSICS, 1987, 14 (02) : 268 - 269
  • [10] X-RAY SOURCES OF MEDICAL LINEAR ACCELERATORS - FOCAL AND EXTRA-FOCAL RADIATION
    JAFFRAY, DA
    BATTISTA, JJ
    FENSTER, A
    MUNRO, P
    [J]. MEDICAL PHYSICS, 1993, 20 (05) : 1417 - 1427