Quantitative SPECT/CT Imaging of 177Lu with In Vivo Validation in Patients Undergoing Peptide Receptor Radionuclide Therapy

被引:45
作者
Sanders, J. C. [1 ,2 ]
Kuwert, T. [2 ]
Hornegger, J. [1 ]
Ritt, P. [1 ,2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, D-91058 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Univ Hosp Erlangen, Clin Nucl Med, D-91054 Erlangen, Germany
关键词
Quantitative SPECT; Lu-177]DOTATATE; Peptide receptor radionuclide therapy; Dosimetry; RESOLUTION; DOSIMETRY; ACCURACY; TUMORS; PET;
D O I
10.1007/s11307-014-0806-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to extend an established SPECT/CT quantitation protocol to Lu-177 and validate it in vivo using urine samples, thus providing a basis for 3D dosimetry of Lu-177 radiotherapy and improvement over current planar methods which improperly account for anatomical variations, attenuation, and overlapping organs. In our quantitation protocol, counts in images reconstructed using an ordered subset-expectation maximization algorithm are converted to kilobecquerels per milliliter using a calibration factor derived from a phantom experiment. While varying reconstruction parameters, we tracked the ratio of image to true activity concentration (recovery coefficient, RC) in hot spheres and a noise measure in a homogeneous region. The optimal parameter set was selected as the point where recovery in the largest three spheres (16, 8, and 4 ml) stagnated, while the noise continued to increase. Urine samples were collected following 12 SPECT/CT acquisitions of patients undergoing [Lu-177]DOTATATE therapy, and activity concentrations were measured in a well counter. Data was reconstructed using parameters chosen in the phantom experiment, and estimated activity concentration from the images was compared to the urine values to derive RCs. In phantom data, our chosen parameter set yielded RCs in 16, 8, and 4 ml spheres of 80.0, 74.1, and 64.5 %, respectively. For patients, the mean bladder RC was 96.1 +/- 13.2 % (range, 80.6-122.4 %), with a 95 % confidence interval between 88.6 and 103.6 %. The mean error of SPECT/CT concentrations was 10.1 +/- 8.3 % (range, -19.4-22.4 %). Our results show that quantitative Lu-177 SPECT/CT in vivo is feasible but could benefit from improved reconstruction methods. Quantifying bladder activity is analogous to determining the amount of activity in the kidneys, an important task in dosimetry, and our results provide a useful benchmark for future efforts.
引用
收藏
页码:585 / 593
页数:9
相关论文
共 34 条
[1]   Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality [J].
Bailey, Dale L. ;
Willowson, Kathy P. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 :S17-S25
[2]   Quantitative 177Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system [J].
Beauregard, Jean-Mathieu ;
Hofman, Michael S. ;
Pereira, Jucilene M. ;
Eu, Peter ;
Hicks, Rodney J. .
CANCER IMAGING, 2011, 11 (01) :56-66
[3]   Preparation and preliminary biological evaluation of 177Lu-labelled htdroxyapatite as a promising agent for radiation synovectomy of small joints [J].
Chakraborty, Sudipta ;
Das, Tapas ;
Banerjee, Sharmila ;
Sarma, Haladhar Dev ;
Venkatesh, Meera .
NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (08) :661-668
[4]   Post-reconstruction non-local means filtering methods using CT side information for quantitative SPECT [J].
Chun, Se Young ;
Fessler, Jeffrey A. ;
Dewaraja, Yuni K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (17) :6225-6240
[5]  
De Jong M, 1998, INT J CANCER, V75, P406, DOI 10.1002/(SICI)1097-0215(19980130)75:3<406::AID-IJC14>3.0.CO
[6]  
2-6
[7]   Somatostatin receptor-targeted radionuclide therapy of tumors: Preclinical and clinical findings [J].
de Jong, M ;
Valkema, R ;
Jamar, F ;
Kvols, LK ;
Kwekkeboom, DJ ;
Breeman, WAP ;
Bakker, WH ;
Smith, C ;
Pauwels, S ;
Krenning, EP .
SEMINARS IN NUCLEAR MEDICINE, 2002, 32 (02) :133-140
[8]   Improving quantitative dosimetry in 177 Lu-DOTATATE SPECT by energy window-based scatter corrections [J].
de Nijs, Robin ;
Lagerburg, Vera ;
Klausen, Thomas L. ;
Holm, Soren .
NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (05) :522-533
[9]   Spatial resolution properties of penalized-likelihood image reconstruction: Space-invariant tomographs [J].
Fessler, JA ;
Rogers, WL .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (09) :1346-1358
[10]   A comparison of 111In-DOTATOC and 111In-DOTATATE:: biodistribution and dosimetry in the same patients with metastatic neuroendocrine tumours [J].
Forrer, F ;
Uusijärvi, H ;
Waldherr, C ;
Cremonesi, M ;
Bernhardt, P ;
Mueller-Brand, J ;
Maecke, HR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (09) :1257-1262