Improving the clinical workflow of a MR-Linac by dosimetric evaluation of synthetic CT

被引:10
作者
Tang, Bin [1 ,2 ]
Liu, Min [1 ]
Wang, Bingjie [3 ]
Diao, Peng [1 ]
Li, Jie [1 ]
Feng, Xi [1 ]
Wu, Fan [1 ]
Yao, Xinghong [1 ]
Liao, Xiongfei [1 ]
Hou, Qing [2 ]
Orlandini, Lucia Clara [1 ]
机构
[1] Univ Elect Sci & Technol China UESTC, Sichuan Canc Hosp & Res Inst, Dept Radiat Oncol, Chengdu, Peoples R China
[2] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, Minist Educ, Chengdu, Peoples R China
[3] Univ Toronto, Fac Arts & Sci, Toronto, ON, Canada
关键词
synthetic CT; clinical workflow; MR-Linac; dosimetry; radiotherapy; RADIATION-THERAPY; ADAPTIVE RADIOTHERAPY; ELECTRON-DENSITY; GUIDED RADIOTHERAPY; GENERATION; IMAGES; VERIFICATION; SIMULATION; HEAD; NECK;
D O I
10.3389/fonc.2022.920443
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Adaptive radiotherapy performed on the daily magnetic resonance imaging (MRI) is an option to improve the treatment quality. In the adapt-to-shape workflow of 1.5-T MR-Linac, the contours of structures are adjusted on the basis of patient daily MRI, and the adapted plan is recalculated on the MRI-based synthetic computed tomography (syCT) generated by bulk density assignment. Because dosimetric accuracy of this strategy is a priority and requires evaluation, this study aims to explore the usefulness of adding an assessment of dosimetric errors associated with recalculation on syCT to the clinical workflow. Sixty-one patients, with various tumor sites, treated using a 1.5-T MR-Linac were included in this study. In Monaco V5.4, the target and organs at risk (OARs) were contoured, and a reference CT plan that contains information about the outlined contours, their average electron density (ED), and the priority of ED assignment was generated. To evaluate the dosimetric error of syCT caused by the inherent approximation within bulk density assignment, the reference CT plan was recalculated on the syCT obtained from the reference CT by forcing all contoured structures to their mean ED defined on the reference plan. The dose-volume histogram (DVH) and dose distribution of the CT and syCT plan were compared. The causes of dosimetric discrepancies were investigated, and the reference plan was reworked to minimize errors if needed. For 54 patients, gamma analysis of the dose distribution on syCT and CT show a median pass rate of 99.7% and 98.5% with the criteria of 3%/3 mm and 2%/2 mm, respectively. DVH difference of targets and OARs remained less than 1.5% or 1 Gy. For the remaining patients, factors (i.e., inappropriate ED assignments) influenced the dosimetric agreement of the syCT vs. CT reference DVH by up to 21%. The causes of the errors were promptly identified, and the DVH dosimetry was realigned except for two lung treatments for which a significant discrepancy remained. The recalculation on the syCT obtained from the planning CT is a powerful tool to assess and decrease the minimal error committed during the adaptive plan on the MRI-based syCT.
引用
收藏
页数:12
相关论文
共 55 条
[1]   A Wake-Up Call for Routine Morbidity and Mortality Review Meeting Procedures as Part of a Quality Governance Programs in Radiation Therapy Departments: Results of the PROUST Survey [J].
Belkacemi, Yazid ;
Colson-Durand, Laurianne ;
Fayolle-Campana, Maryse ;
Pons, Pascale ;
Rialland, Amandine ;
Bastuji-Garin, Sylvie ;
Quy Nguyen Hoang ;
Lerouge, Delphine ;
Jaffre, Francoise ;
Bollet, Marc ;
Azria, David .
PRACTICAL RADIATION ONCOLOGY, 2019, 9 (02) :108-114
[2]   First clinical experiences with a high field 1.5 T MR linac [J].
Bertelsen, Anders S. ;
Schytte, Tine ;
Moller, Pia K. ;
Mahmood, Faisal ;
Riis, Hans L. ;
Gottlieb, Karina L. ;
Agergaard, Soren N. ;
Dysager, Lars ;
Hansen, Olfred ;
Gornitzka, Janne ;
Veldhuizen, Elisabeth ;
ODwyer, Dean B. ;
Christiansen, Rasmus L. ;
Nielsen, Morten ;
Jensen, Henrik R. ;
Brink, Carsten ;
Bernchou, Uffe .
ACTA ONCOLOGICA, 2019, 58 (10) :1352-1357
[3]   Low Tesla magnetic resonance guided radiotherapy for locally advanced cervical cancer: first clinical experience [J].
Boldrini, Luca ;
Piras, Antonio ;
Chiloiro, Giuditta ;
Autorino, Rosa ;
Cellini, Francesco ;
Cusumano, Davide ;
Fionda, Bruno ;
D'Aviero, Andrea ;
Campitelli, Maura ;
Marazzi, Fabio ;
Balducci, M. ;
Valentini, Vincenzo ;
Gambacorta, Maria Antonietta .
TUMORI JOURNAL, 2020, 106 (06) :497-505
[4]   1.5 T MR-linac planning study to compare two different strategies of rectal boost irradiation [J].
Bonomo, Pierluigi ;
Lo Russo, Monica ;
Nachbar, Marcel ;
Boeke, Simon ;
Gatidis, Sergios ;
Zips, Daniel ;
Thorwarth, Daniela ;
Gani, Cihan .
CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2021, 26 :86-91
[5]   Systematic review of educational interventions to improve contouring in radiotherapy [J].
Cacicedo, Jon ;
Navarro-Martin, Arturo ;
Gonzalez-Larragan, Susana ;
De Bari, Berardino ;
Salem, Ahmed ;
Dahele, Max .
RADIOTHERAPY AND ONCOLOGY, 2020, 144 :86-92
[6]   Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype [J].
Catana, Ciprian ;
van der Kouwe, Andre ;
Benner, Thomas ;
Michel, Christian J. ;
Hamm, Michael ;
Fenchel, Matthias ;
Fischl, Bruce ;
Rosen, Bruce ;
Schmand, Matthias ;
Sorensen, A. Gregory .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) :1431-1438
[7]   Head and neck radiotherapy on the MR linac: a multicenter planning challenge amongst MRIdian platform users [J].
Chamberlain, Madalyne ;
Krayenbuehl, Jerome ;
van Timmeren, Janita E. ;
Wilke, Lotte ;
Andratschke, Nicolaus ;
Garcia Schueler, Helena ;
Tanadini-Lang, Stephanie ;
Guckenberger, Matthias ;
Balermpas, Panagiotis .
STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (12) :1093-1103
[8]   MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT [J].
Chen, LL ;
Price, RA ;
Wang, L ;
Li, JS ;
Qin, LH ;
McNeeley, S ;
Ma, CMC ;
Freedman, GM ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02) :636-647
[9]   Technical Note: U-net-generated synthetic CT images for magnetic resonance imaging-only prostate intensity-modulated radiation therapy treatment planning [J].
Chen, Shupeng ;
Qin, An ;
Zhou, Dingyi ;
Yan, Di .
MEDICAL PHYSICS, 2018, 45 (12) :5659-5665
[10]   Magnetic resonance-guided radiation therapy: A review [J].
Chin, Stephen ;
Eccles, Cynthia L. ;
McWilliam, Alan ;
Chuter, Robert ;
Walker, Emma ;
Whitehurst, Philip ;
Berresford, Joseph ;
Van Herk, Marcel ;
Hoskin, Peter J. ;
Choudhury, Ananya .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2020, 64 (01) :163-177