Visual and Optical Performance With Two Different Diffractive Multifocal Intraocular Lenses Compared to a Monofocal Lens

被引:39
作者
Alio, Jorge L. [1 ,2 ]
Pinero, David P. [1 ,3 ]
Plaza-Puche, Ana B. [1 ]
Amparo, Francisco [1 ]
Jimenez, Ramon [1 ]
Rodriguez-Prats, Jose L. [1 ]
Javaloy, Jaime [1 ]
机构
[1] Vissum Corp, Inst Oftalmol Alicante, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Univ Alicante, Dept Opt Farmacol & Anat, E-03080 Alicante, Spain
关键词
WAVE-FRONT ABERRATION; MICROINCISION CATARACT-SURGERY; CONTRAST SENSITIVITY; SPHERICAL-ABERRATION; RETINAL STRAYLIGHT; CLINICAL-OUTCOMES; IMAGE QUALITY; IMPLANTATION; RESTOR; IOL;
D O I
10.3928/1081597X-20101223-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the visual acuity outcomes as well as the ocular optical performance of eyes implanted with either a monofocal or one of two diffractive multifocal intraocular lenses (IOLs). METHODS: One hundred two consecutive eyes of 51 bilateral cataract patients (age 49 to 80 years) were divided into three groups: 22 eyes were implanted with a monofocal IOL (monofocal group), 40 eyes with the Acrysof ReSTOR SN6AD3 IOL (ReSTOR group), and 40 eyes with the Acri.Lisa 366D IOL (Acri.Lisa group). Visual acuity and contrast sensitivity were evaluated pre- and postoperatively. Additionally, ocular optical quality and intraocular aberrations were evaluated postoperatively. RESULTS: Significant improvement after surgery in uncorrected and corrected distance and near visual acuity was observed in all three groups (P <.05). Uncorrected near visual acuity was significantly better in eyes from the ReSTOR and Acri.Lisa groups compared to the monofocal group (P <.01). Photopic contrast sensitivity was significantly better for the spatial frequency of 3 cycles/degree in the monofocal group (P <.01). Significantly higher values of the ocular Strehl ratio and cutoff modulation transfer function spatial frequency were also found in the Acri. Lisa group (P=. 01). An acceptable range of vision between near and distance peaks was observed in the defocus curves of the ReSTOR and Acri. Lisa groups. CONCLUSIONS: The AcrySof ReSTOR and Acri. Lisa 366D IOLs are able to successfully restore near and intermediate visual function after cataract surgery; however, the Acri. Lisa design seems to provide better optical performance. These results need to be confirmed in a randomized, prospective trial. [J Refract Surg. 2011; 27(8): 570-581.] doi:10.3928/1081597X-20101223-01
引用
收藏
页码:570 / 581
页数:12
相关论文
共 56 条
[1]   Prospective study of the Acri.LISA bifocal intraocular lens [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Senaris, Ana ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1930-1935
[2]   Prospective visual evaluation of apodized diffractive intraocular lenses [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Baamonde, M. Begona ;
Mont-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) :1235-1243
[3]   Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses [J].
Alfonso, Jose F. ;
Puchades, Cristina ;
Fernandez-Vega, Luis ;
Montes-Mico, Robert ;
Valcarcel, Beatriz ;
Ferrer-Blasco, Teresa .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :672-676
[4]   Outcomes of microincision cataract surgery versus coaxial phacoemulsification [J].
Alió, J ;
Rodríguez-Prats, JL ;
Galal, A ;
Ramzy, M .
OPHTHALMOLOGY, 2005, 112 (11) :1997-2003
[5]   Crystalline lens optical dysfunction through aging [J].
Alió, JL ;
Schimchak, P ;
Negri, HP ;
Montés-Micó, R .
OPHTHALMOLOGY, 2005, 112 (11) :2022-2029
[6]   Visual outcome of microincision cataract surgery with implantation of an Acri.Smart lens [J].
Alió, JL ;
Rodriguez-Prats, JL ;
Vianello, A ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1549-1556
[7]   Retinal image quality after microincision intraocular lens implantation [J].
Alió, JL ;
Schimchak, P ;
Montés-Micó, R ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1557-1560
[8]   Near vision restoration with refractive lens exchange and pseudoaccommodating and multifocal refractive and diffractive intraocular lenses -: Comparative clinical study [J].
Alió, JL ;
Tavolato, M ;
De la Hoz, F ;
Claramonte, P ;
Rodríguez-Prats, JL ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12) :2494-2503
[9]   Microincision multifocal intraocular lens with and without a capsular tension ring -: Optical quality and clinical outcomes [J].
Alio, Jorge L. ;
Elkady, Bassam ;
Ortiz, Dolores ;
Bernabeu, Gonzalo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1468-1475
[10]   Clinical outcomes and intraocular optical quality of a diffractive multifocal intraocular lens with asymmetrical light distribution [J].
Alio, Jorge L. ;
Elkady, Bassarn ;
Ortiz, Dolores ;
Bernabeu, Gonzalo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :942-948