Reduction of interior temperature of mass concrete using suspension of phase change materials as cooling fluid

被引:52
作者
Qian, Chunxiang [1 ]
Gao, Guibo
机构
[1] Southeast Univ, Sch Mat Sci & Engn, Nanjing 211189, Peoples R China
关键词
Suspension of phase change material; Concrete; Hydrated heat; Interior temperature; Temperature gradient; HEAT-TRANSFER;
D O I
10.1016/j.conbuildmat.2011.06.053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to evaluate the effect of suspension of phase change material (SPCM) on interior temperature rise and temperature gradient in concrete, a semi-adiabatic device was designed to measure the temperature changing in concrete specimens. Both SPCM and water were used as cooling fluid to evaluate its cooling effect. The temperature difference (TD) and temperature gradient (TG) at different locations were tested and analyzed. The consumption of cooling fluid and corresponding temperature difference between concrete and cooling fluid was also calculated. The results showed that when water was replaced by SPCM as cooling fluid, the temperature reducing extent can be increased 27-28%, and the temperature difference can be decrease 7.6-8.4%. SPCM has a great significance on the cooling of interior temperature rise caused by cement hydration. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:527 / 531
页数:5
相关论文
共 16 条
[1]  
Bentz Dale P, 2006, CEMENT CONCRETE COMP, V29, P527
[2]  
[陈斌娇 Chen Binjiao], 2009, [太阳能学报, Acta Energiae Solaris Sinica], V30, P1018
[3]   LAMINAR FORCED-CONVECTION HEAT-TRANSFER IN MICROCAPSULATED PHASE-CHANGE MATERIAL SUSPENSIONS [J].
GOEL, M ;
ROY, SK ;
SENGUPTA, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (04) :593-604
[4]   Melting heat transfer characteristics of microencapsulated phase change material slurries with plural microcapsules having different diameters [J].
Inaba, H ;
Kim, MJ ;
Horibe, A .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2004, 126 (04) :558-565
[5]  
Li J J, 2004, GUIZHOU WATER POWER, V18, P46
[6]  
Liu GY, 2006, STUDY OPTIMAL ARRANG, V25, P16
[7]  
Lu, 2007, CHINA CONCR CEM PROD, P9
[8]  
[马跃峰 MA Yuefeng], 2006, [水利学报, Journal of Hydraulic Engineering], V37, P963
[9]   Effect of double layer phase change material in building roof for year round thermal management [J].
Pasupathy, A. ;
Velraj, R. .
ENERGY AND BUILDINGS, 2008, 40 (03) :193-203
[10]  