Power quality surveys of photovoltaic power plants: characterisation and analysis of grid-code requirements

被引:56
作者
Honrubia-Escribano, Andres [1 ,2 ]
Garcia-Sanchez, Tania [1 ,2 ]
Gomez-Lazaro, Emilio [1 ,2 ]
Muljadi, E. [3 ]
Molina-Garcia, Angel [4 ]
机构
[1] Univ Castilla La Mancha, Renewable Energy Res Inst, Albacete 02071, Spain
[2] Univ Castilla La Mancha, DIEEAC EDII AB, Albacete 02071, Spain
[3] Natl Renewable Energy Lab, Golden, CO USA
[4] Univ Politecn Cartagena, Dept Elect Engn, Cartagena 30202, Spain
关键词
photovoltaic power systems; power supply quality; power grids; power generation reliability; power quality surveys; photovoltaic power plants; European grid-code requirements; power system operation reliability; Spanish PV power plants; fixed array installation; power capacity; dual axis-trackers; voltage dips; supply interruptions; tabular representations; graphical representations; time interval; residual voltage; power; 1; MW; 4; 5; VOLTAGE DIPS;
D O I
10.1049/iet-rpg.2014.0215
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the past few years, grid-code requirements for grid-connected photovoltaic power plants have experienced a continuous evolution in different countries to ensure a reliable power system operation as the level of renewable energy penetration increases to high levels. According to several European grid-codes, PV power plants must be able to ride through specific and severe disturbances without disconnections. Under this new framework, the present study analyses intensive power quality surveys carried out from 2008 to 2011 in three different Spanish PV power plants: a fixed array installation with 4 MW PV power capacity, a PV power plant including dual axis-trackers with 1 MW PV power capacity, and one more fixed array PV power plant with 5 MW PV power capacity. Voltage dips and supply interruptions have been collected, discussing several methods to characterise the monitored disturbances and to compare these events to current Grid-Code requirements. Furthermore, the time interval around the residual voltage is proposed and defined by the authors as an additional parameter to provide a complete characterisation of the severity of the disturbances. Results from both characterisations of collected data and comparison with current requirements are also included in the study.
引用
收藏
页码:466 / 473
页数:8
相关论文
共 56 条
[1]  
Akram MF, 2001, IEEE INMIC 2001: IEEE INTERNATIONAL MULTI TOPIC CONFERENCE 2001, PROCEEDINGS, P38, DOI 10.1109/INMIC.2001.995311
[2]  
[Anonymous], 20 INT C EXH EL DIST
[3]  
[Anonymous], 2011, World Energy Outlook 2010
[4]  
[Anonymous], 2 INT WORKSH INT SOL
[5]  
[Anonymous], 2009, IEEE Recommended Practice for Software Requirements Specifications
[6]  
[Anonymous], 2012, PROC VER VAL CERT RE
[7]  
[Anonymous], 22 AUSTR U POW ENG C
[8]  
[Anonymous], 2009, 2009 INT C POW SYST
[9]  
[Anonymous], 2014, GLOBAL MARKET OUTLOO
[10]  
[Anonymous], TECHNICAL REPORT