Assessment of tear film dynamics: Quantification approach

被引:140
作者
Tomlinson, A [1 ]
Khanal, S [1 ]
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
关键词
absorption; distribution; evaporation; osmolarity; tear dynamics; tear indices; tear turnover;
D O I
10.1016/S1542-0124(12)70157-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The dynamics of the tear film are reviewed with specific reference to the biophysical aspects: distribution, turnover and elimination through evaporation, drainage, and absorption. The review concentrates on quantitative assessments and is confined to aspects of the dynamics that can be fully and directly measured. The techniques of fluorophotometry, fluorescein clearance, lacrimal scintigraphy, evaporimetry and osmometry are described. Reports in the literature for values of tear turnover (flow), evaporation and osmolarity for normal and dry eyes are collated. Indices of tear film dynamics based on these measurements, including tear function index, total tear flow, and osmolarity, are discussed in relation to their potential in the differential diagnosis of dry eye and new referent values for the disease suggested. The limitations of derivation and application of these indices are discussed.
引用
收藏
页码:81 / 95
页数:15
相关论文
共 120 条
[1]   Correlation of tear fluorescein clearance and Schirmer test scores with ocular irritation symptoms [J].
Afonso, AA ;
Monroy, D ;
Stern, ME ;
Feuer, WJ ;
Tseng, SCG ;
Pflugfelder, SC .
OPHTHALMOLOGY, 1999, 106 (04) :803-810
[2]  
[Anonymous], FOLIA OPHTHALMOL JPN
[3]  
[Anonymous], 1982, J BR CONTACT LENS AS, DOI DOI 10.1016/S0141-7037(82)80022-0
[4]   The cavernous body of the human efferent tear ducts contributes to regulation of tear outflow [J].
Ayub, M ;
Thale, AB ;
Hedderich, J ;
Tillmann, BN ;
Paulsen, FP .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (11) :4900-4907
[5]   TONICITY OF HUMAN TEAR FLUID SAMPLED FROM THE CUL-DE-SAC [J].
BENJAMIN, WJ ;
HILL, RM .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (08) :624-627
[6]  
Bron AJ, 2002, ADV EXP MED BIOL, V506, P1087
[7]  
CHAVIS RM, 1978, ARCH OPHTHALMOL-CHIC, V96, P2066
[8]   SCHIRMER TEST - A CLOSER LOOK [J].
CLINCH, TE ;
BENEDETTO, DA ;
FELBERG, NT ;
LAIBSON, PR .
ARCHIVES OF OPHTHALMOLOGY, 1983, 101 (09) :1383-1386
[9]  
CRAIG JP, 1995, INVEST OPHTH VIS SCI, V36, pS1043
[10]   Importance of the lipid layer in human tear film stability and evaporation [J].
Craig, JP ;
Tomlinson, A .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (01) :8-13