Reference Values of Native T1 at 3T Cardiac Magnetic Resonance-Standardization Considerations between Different Vendors

被引:5
作者
Tribuna, Liliana [1 ]
Oliveira, Pedro Belo [1 ,2 ]
Iruela, Alba [3 ]
Marques, Joao [1 ]
Santos, Paulo [1 ]
Teixeira, Tiago [1 ,4 ]
机构
[1] Hosp Luz Aveiro, Dept Radiol, P-3800009 Aveiro, Portugal
[2] Ctr Hosp Univ Coimbra, Dept Radiol, P-3004561 Coimbra, Portugal
[3] Canon Med Syst Spain & Portugal, MR, Cornella De Llobregat 08940, Spain
[4] Ctr Hosp Entre Douro & Vouga, Dept Cardiol, P-4520211 Santa Maria Feira, Portugal
关键词
cardiac MR; native T1 mapping; MOLLI; HEALTHY-VOLUNTEERS; VOLUME;
D O I
10.3390/diagnostics11122334
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed at establishing native T1 reference values for a Canon Vantage Galan 3T system and comparing them with previously published values from different vendors. A total of 20 healthy volunteers (55% Women; 33.9 +/- 11.1 years) underwent left ventricular T1 mapping at 3T MR. A MOLLI 5(3)3 sequence was used, acquiring three short-axis slices. Native T1 values are shown as means (+/- standard deviation) and Student's independent samples t-test was used to test gender differences in T1 values. Pearson's correlation coefficient analysis was used to compare two processes of T1 analysis. The results show a global native T1 mean value of 1124.9 +/- 55.2 ms (exponential analysis), that of women being statistically higher than men (1163 +/- 30.5 vs. 1077.9 +/- 39.5 ms, respectively; p < 0.001). There were no specific tendencies for T1 times in different ventricular slices. We found a strong correlation (0.977, p < 0.001) with T1 times derived from parametric maps (1136.4 +/- 60.2 ms). Native T1 reference values for a Canon 3T scanner were provided, and they are on par with those already reported from other vendors for a similar sequence. We also found a correlation between native T1 and gender, with higher values for women.
引用
收藏
页数:10
相关论文
共 33 条
[1]   Clinical evaluation of left ventricular function and morphology using an accelerated k-t sensitivity encoding method in cardiovascular magnetic resonance [J].
Assuncao-, Antonildes Nascimento, Jr. ;
Dantas-, Roberto Nery, Jr. ;
do Val, Renata Margarida ;
Gianotto, Priscilla ;
Marin, Angela dos Santos ;
Golden, Mark ;
Gutierrez, Marco Antonio ;
Parga, Jose Rodrigues ;
Nomura, Cesar Higa .
INSIGHTS INTO IMAGING, 2019, 10 (01)
[2]  
Attenberger U.I, 2008, INVEST RADIOL, V12, P69
[3]   Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping [J].
Chow, Kelvin ;
Flewitt, Jacqueline A. ;
Green, Jordin D. ;
Pagano, Joseph J. ;
Friedrich, Matthias G. ;
Thompson, Richard B. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) :2082-2095
[4]   Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study [J].
Dabir, Darius ;
Child, Nicholas ;
Kalra, Ashwin ;
Rogers, Toby ;
Gebker, Rolf ;
Jabbour, Andrew ;
Plein, Sven ;
Yu, Chung-Yao ;
Otton, James ;
Kidambi, Ananth ;
McDiarmid, Adam ;
Broadbent, David ;
Higgins, David M. ;
Schnackenburg, Bernhard ;
Foote, Lucy ;
Cummins, Ciara ;
Nagel, Eike ;
Puntmann, Valentina O. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[5]   Contrast-Enhanced T1-Mapping MRI for the Assessment of Myocardial Fibrosis [J].
de Graaf W.L. ;
Vandoorne K. ;
Arslan F. ;
Nicolay K. ;
Strijkers G.J. .
Current Cardiovascular Imaging Reports, 2014, 7 (4) :1-12
[6]   Improving the robustness of MOLLI T1 maps with a dedicated motion correction algorithm [J].
Delso, Gaspar ;
Farre, Laura ;
Ortiz-Perez, Jose T. ;
Prat, Susanna ;
Doltra, Adelina ;
Perea, Rosario J. ;
Caralt, Teresa M. ;
Lorenzatti, Daniel ;
Vega, Julian ;
Sotes, Santi ;
Janich, Martin A. ;
Sitges, Marta .
SCIENTIFIC REPORTS, 2021, 11 (01)
[7]   Age and Gender Impact the Measurement of Myocardial Interstitial Fibrosis in a Healthy Adult Chinese Population: A Cardiac Magnetic Resonance Study [J].
Dong, Yang ;
Yang, Dan ;
Han, Yuchi ;
Cheng, Wei ;
Sun, Jiayu ;
Wan, Ke ;
Liu, Hong ;
Greiser, Andreas ;
Zhou, Xiaoyue ;
Chen, Yucheng .
FRONTIERS IN PHYSIOLOGY, 2018, 9
[8]   CMR Parametric Mapping as a Tool for Myocardial Tissue Characterization [J].
Ferreira, Vanessa M. ;
Piechnik, Stefan K. .
KOREAN CIRCULATION JOURNAL, 2020, 50 (08) :658-676
[9]   Native T1 and Extracellular Volume Measurements by Cardiac MRI in Healthy Adults: A Meta-Analysis [J].
Gottbircht, Matthew ;
Kramer, Christopher M. ;
Salerno, Michael .
RADIOLOGY, 2019, 290 (02) :317-326
[10]   Comparison of native myocardial T1 and T2 mapping at 1.5T and 3T in healthy volunteers Reference values and clinical implications [J].
Granitz, Marcel ;
Motloch, Lukas J. ;
Granitz, Christina ;
Meissnitzer, Matthias ;
Hitzl, Wolfgang ;
Hergan, Klaus ;
Schlattau, Alexander .
WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 (7-8) :143-155