Impact of VV optimization in relation to left ventricular lead position: an acute haemodynamic study

被引:10
作者
Khan, Fakhar Z. [1 ]
Virdee, Munmohan S. [2 ]
Read, Philip A. [1 ]
Pugh, Peter J. [1 ]
Begley, David [2 ]
Fynn, Simon P. [2 ]
Dutka, David P. [1 ]
机构
[1] Addenbrookes Hosp, Cambridge CB2 2QQ, England
[2] Papworth Hosp, Cambridge CB23 8RE, England
来源
EUROPACE | 2011年 / 13卷 / 06期
关键词
CRT; VV delay; LV lead; Cardiac output; CARDIAC-RESYNCHRONIZATION THERAPY; CHRONIC HEART-FAILURE; 2-DIMENSIONAL STRAIN; SYSTOLIC FUNCTION; ATRIOVENTRICULAR DELAY; DILATED CARDIOMYOPATHY; RADIAL STRAIN; ECHOCARDIOGRAPHY; DEFIBRILLATOR; IMPLANTATION;
D O I
10.1093/europace/eur037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Left ventricular (LV) lead placement to the most delayed segment offers the greatest potential benefit to cardiac resynchronization therapy (CRT). We assessed the impact of interventricular (VV) optimization on acute changes in cardiac output (CO) in patients with and without LV pacing of the most delayed segment. Methods and results In 124 patients, the most delayed segment was defined by speckle tracking radial strain and the LV lead position by biplane fluoroscopy. Patients were classified as either a concordant (LV lead at latest site), adjacent (within one segment), or remote (two or more segments away) LV lead. Atrioventricular (AV) and VV delays were optimized by echocardiography. Cardiac output was measured non-invasively and a > 20% increase in CO from baseline (intrinsic) defined acute response. Changes in CO in patients with concordant, adjacent, or remote LV leads were recorded following atrioventricular optimization alone (AV OPT) and after combined AV and VV optimization (AV/VV OPT). Compared with AV OPT pacing, AV/VV OPT produced a greater rise in CO (5.45 +/- 1.1 vs. 5.76 +/- 1.2 L/min, P < 0.001) and higher acute response rates (48.4 vs. 61.3%, P = 0.041). In adjacent patients, compared with AV OPT pacing, AV/VV OPT settings increased the response rate from 36.4 to 63.6% (P = 0.037). VV optimization had no effect on acute response rates in patients with remote (26.7 vs. 33.3%, P = 0.581) or concordant LV leads (65.6 vs. 72.1%, P = 0.438). Conclusion VV optimization overcomes some but not all of the deleterious effects of a suboptimal LV lead position.
引用
收藏
页码:845 / 852
页数:8
相关论文
共 35 条
  • [21] Comparison of left ventricular lead placement via the coronary venous approach versus lateral thoracotomy in patients receiving cardiac resynchronization therapy
    Koos, R
    Sinha, AM
    Markus, K
    Breithardt, OA
    Mischke, K
    Zarse, M
    Schmid, M
    Autschbach, R
    Hanrath, P
    Stellbrink, C
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (01) : 59 - 63
  • [22] Two-dimensional strain - A novel software for real-time quantitative echocardiographic assessment of myocardial function
    Leitman, M
    Lysyansky, P
    Sidenko, S
    Shir, V
    Peleg, E
    Binenbaum, M
    Kaluski, E
    Krakover, R
    Vered, Z
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (10) : 1021 - 1029
  • [23] Cardiac resynchronization with sequential biventricular pacing for the treatment of moderate-to-severe heart failure
    León, AR
    Abraham, WT
    Brozena, S
    Daubert, JP
    Fisher, WG
    Gurley, JC
    Liang, CS
    Wong, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) : 2298 - 2304
  • [24] Tissue synchronization imaging and optimal left ventricular pacing site in cardiac resynchronization therapy
    Murphy, Ross T.
    Sigurdsson, Gardar
    Mulamalla, Sumanth
    Agler, Deborah
    Popovic, Zoran B.
    Starling, Randall C.
    Wilkoff, Bruce L.
    Thomas, James D.
    Grimm, Richard A.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (11) : 1615 - 1621
  • [25] Non-Doppler two-dimensional strain imaging by echocardiography - From technical considerations to clinical applications
    Perk, Gila
    Tunick, Paul A.
    Kronzon, Itzhak
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (03) : 234 - 243
  • [26] Reduced ventricular volumes and improved systolic function with cardiac resynchronization therapy - A randomized trial comparing simultaneous biventricular pacing, sequential biventricular pacing, and left ventricular pacing
    Rao, Rajni K.
    Kumar, Uday N.
    Schafer, Jill
    Viloria, Esperanza
    De Lurgio, David
    Foster, Elyse
    [J]. CIRCULATION, 2007, 115 (16) : 2136 - 2144
  • [27] Global longitudinal strain: A novel index of left ventricular systolic function
    Reisner, SA
    Lvsvanskv, P
    Agmon, Y
    Mutlak, D
    Lcssick, J
    Friccinian, Z
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (06) : 630 - 633
  • [28] Schiller N B, 1989, J Am Soc Echocardiogr, V2, P358
  • [29] Noninvasive cardiac output monitoring (NICOM): a clinical validation
    Squara, Pierre
    Denjean, Dominique
    Estagnasie, Philippe
    Brusset, Alain
    Dib, Jean Claude
    Dubois, Claude
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (07) : 1191 - 1194
  • [30] Optimization of cardiac resynchronization guided by Doppler echocardiography: haemodynamic improvement and intraindividual variability with different pacing configurations and atrioventricular delays
    Stockburger, Martin
    Fateh-Moghadam, Suzanne
    Nitardy, Aischa
    Langreck, Holger
    Haverkamp, Wilhelm
    Dietz, Rainer
    [J]. EUROPACE, 2006, 8 (10): : 881 - 886