Experimental Validation of ANSYS CFX for Transient Flows With Heat Transfer in a Tubular Heat Exchanger

被引:1
|
作者
Papukchiev, Angel [1 ]
机构
[1] Gesell Anlagen & Reaktorsicherheit GRS gGmbH, Boltzmannstr 14, D-85748 Garching, Bavaria, Germany
来源
JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE | 2020年 / 6卷 / 02期
基金
欧盟地平线“2020”;
关键词
TURBULENT PRANDTL;
D O I
10.1115/1.4045074
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Within the European SESAME project, extensive experimental work was performed and complemented by the development, application, and validation activities of thermalhydraulic simulation tools for different scales. The TALL-3D experimental facility, operated by KTH Royal Institute of Technology in Stockholm, is designed for thermalhydraulic experiments with lead-bismuth eutectic (LBE) coolant at natural and forced circulation conditions. The heat generated in the primary TALL-3D circuit is transferred via a double-tube counter-flow heat exchanger (HX) to the secondary side, which is cooled by glycerol oil. Validation calculations with the coupled simulation code ATHLET-ANSYS CFX within the European THINS project showed that one of the major challenges for this one-dimensional-three-dimensional (1D-3D) simulation of the experimental facility lies in the calculation of the HX with ATHLET. This is due to the fact that glycerol oil properties are not yet available for ATHLET. In order to better understand the flow and heat transfer phenomena inside the HX, 3D stand-alone calculations with ANSYS CFX were carried out for the SESAME experiment TG03.S301.03. The data generated in this experimental run is challenging for validation of computational fluid dynamics (CFD) codes, because the test combines heat transfer between buoyancydriven LBE flow in the primary circuit and a turbulent oil flow in the secondary TALL-3D side. Moreover, the validation gets even more difficult for the CFD approach due to the fact that both coolants are nonunity Prandtl fluids, and this requires a careful modeling of the turbulent heat flux. In this paper, the TALL-3D HX behavior during test TG03.S301.03 is analyzed, and the results of the ANSYS CFX calculations are compared with measurements.
引用
收藏
页数:9
相关论文
共 4 条
  • [1] EXPERIMENTAL VALIDATION OF ANSYS CFX FOR TRANSIENT FLOWS WITH HEAT TRANSFER IN A TUBULAR HEAT EXCHANGER
    Papukchiev, Angel
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 8, 2018,
  • [2] Heat transfer characteristics and design optimization of compact heat exchanger with liquid lead-bismuth eutectic and sCO2 as working fluids
    Luo, Zhiyuan
    Li, Gen
    PROGRESS IN NUCLEAR ENERGY, 2025, 184
  • [3] Numerical study on the heat transfer characteristics of a microchannel heat exchanger with liquid lead-bismuth eutectic and supercritical CO2 as working fluids
    Liu, Hong
    Zhang, Zhigang
    Du, Haisu
    Cong, Tenglong
    Yang, Shuo
    ANNALS OF NUCLEAR ENERGY, 2023, 192
  • [4] Experimental and numerical analysis of heat transfer characteristics of liquid lead in triangular rod bundles
    Liu, Yang
    Shi, Qianwan
    Wang, Xiangyang
    Wang, Yongquan
    Zhang, Lu
    Guan, Xingcai
    Gu, Long
    ANNALS OF NUCLEAR ENERGY, 2025, 214