SPICE Models for Prediction of Disturbances Induced by Nonuniform Fields on Shielded Cables

被引:27
|
作者
Xie, Haiyan [1 ]
Wang, Jianguo [1 ,2 ]
Fan, Ruyu [1 ,2 ]
Liu, Yinong [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] NW Inst Nucl Technol, Xian 710024, Peoples R China
基金
中国国家自然科学基金;
关键词
Electromagnetic interference; nonuniform field; radiated susceptibility; shielded cables; SPICE model; VOLTAGES; CIRCUIT;
D O I
10.1109/TEMC.2010.2045895
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents SPICE models for the prediction of effects on shielded cables induced by nonuniform fields. Based on the transmission line theory, these models can be utilized to analyze shielded cables terminated with nonlinear or time-varying loads excited by nonuniform fields in the time domain. Two examples, a coaxial shielded cable and a two-parallel-wire shielded cable, both inside a cavity with a slot excited by an incident wave, are studied with the proposed models. The finite-difference time-domain method is employed to calculate the excitation fields of the cables, and then, the SPICE models are utilized to obtain the disturbances induced by the incident wave on the cables. The results obtained by the proposed models agree well with those obtained through other methods.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 50 条
  • [21] RADIATION-INDUCED CURRENTS IN SHIELDED MULTI-CONDUCTOR AND SEMIRIGID CABLES
    FITZWILSON, RL
    BERNSTEIN, MJ
    ALSTON, TE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (06) : 276 - 283
  • [22] Lightning induced disturbances in buried cables - Part I: Theory
    Petrache, E
    Rachidi, F
    Paolone, M
    Nucci, CA
    Rakov, VA
    Uman, MA
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2005, 47 (03) : 498 - 508
  • [24] VOLTAGES INDUCED ON COAXIAL CABLES OR MULTI-WIRE SHIELDED LINES BY A DISTURBING WAVE
    ZEDDAM, A
    KONE, L
    DEGAUQUE, P
    ELECTROMAGNETICS, 1988, 8 (2-4) : 311 - 333
  • [25] Experimental validation of circuit models for Bulk Current Injection (BCI) Test on shielded coaxial cables
    Antonini, G
    Scogna, AC
    Orlandi, A
    Rizzi, RM
    2004 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SYMPOSIUM RECORD 1-3, 2004, : 63 - 68
  • [26] Calculation of Electric Fields in HVDC Cables: Comparison of Different Models
    Kumara, Sarath
    Serdyuk, Yuriy, V
    Jeroense, Marc
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (03) : 1070 - 1078
  • [27] INDUCED TRANSIENTS IN SUBSTATION CABLES - MEASUREMENTS AND MODELS
    THOMAS, DE
    WIGGINS, CM
    SALAS, TM
    NICKEL, FS
    WRIGHT, SE
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (04) : 1861 - 1868
  • [28] Transient electromagnetic lightning disturbances induced in the collector cables of a wind farm
    Boussayoud, L.
    Nekhoul, B.
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 241
  • [29] New extraction procedure of shielded cable SPICE macro-model for the prediction of signal integrity and conducted immunity
    Araneo, Rodolfo
    Caniggia, Spartaco
    Maradei, Francescaromana
    2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1-3, PROCEEDINGS, 2006, : 751 - 755
  • [30] Circuit models of lossy coaxial shielded cables to analyze radiated and conducted susceptibilities with unmatched line loads
    Saih M.
    Rouijaa H.
    Ghammaz A.