Common-path optical coherence tomography using a microelectromechanical-system-based endoscopic probe

被引:8
|
作者
Wang, Donglin [1 ,3 ]
Duan, Can [2 ]
Zhang, Xiaoyang [2 ]
Yun, Zhao [3 ]
Pozzi, Antonio [4 ]
Xie, Huikai [2 ,3 ]
机构
[1] Zhengzhou Univ Light Ind, Sch Phys & Elect Engn, Zhengzhou 450002, Peoples R China
[2] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
[3] WiO Technol Ltd Co, Wuxi 214028, Peoples R China
[4] Univ Zurich, Clin Small Anim Surg, CH-8006 Zurich, Switzerland
基金
美国国家科学基金会;
关键词
NUMERICAL DISPERSION COMPENSATION; HIGH-SPEED; ULTRAHIGH-RESOLUTION; DOPPLER TOMOGRAPHY; MIRROR; VELOCITY; INTERFEROMETER; SENSITIVITY; SCANNER; COLON;
D O I
10.1364/AO.55.006930
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper presents a common-path (CP) swept-source optical coherence tomography (SSOCT) system based on a special endoscopic probe design with an in-line internal reflection as the reference and a two-axis electrothermal microelectromechanical system mirror for image scanning. The rear surface of a gradient reflective index (GRIN) lens inside the probe is set as the reference reflection plane. The length of the GRIN lens is optimized to eliminate the artifacts in SSOCT images successfully. Doppler OCT is also demonstrated based on the CP endoscopic probe. The diameter of the probe is only 2.5 mm, so it can be easily inserted into the biopsy channel of traditional endoscopes to access human internal organs for in vivo diagnoses. (C) 2016 Optical Society of America
引用
收藏
页码:6930 / 6935
页数:6
相关论文
共 50 条
  • [1] Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence tomography
    Sharma, Utkarsh
    Kang, Jin U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (11):
  • [2] Swept-source common-path optical coherence tomography with a MEMS endoscopic imaging probe
    Duan, Can
    Wang, Donglin
    Zhou, Zhengwei
    Liang, Peng
    Samuelson, Sean R.
    Pozzi, Antonio
    Xie, Huikai
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [3] Double common-path interferometer for flexible optical probe of optical coherence tomography
    Park, Jae Seok
    Chen, Zhongping
    Jeong, Myung Yung
    Kim, Chang-Seok
    OPTICS EXPRESS, 2012, 20 (02): : 1102 - 1112
  • [4] Optimization of an angled fiber probe for common-path optical coherence tomography
    Liu, Xuan
    Kang, Jin U.
    OPTICS LETTERS, 2013, 38 (15) : 2660 - 2662
  • [5] Reference optimization for a common-path optical coherence tomography probe using angle polishing
    Liu, Xuan
    Kang, Jin U.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [6] Endoscopic Functional Fourier Domain Common-Path Optical Coherence Tomography for Microsurgery
    Kang, Jin U.
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    Song, Chul Gyu
    Gehlbach, Peter
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2010, 16 (04) : 781 - 792
  • [7] Common-path optical coherence tomography using Bessel beam axicon probe for malignancy identification
    Gupta, P.
    Vairagi, K.
    Sharma, V.
    Prasad, K. K.
    Mondal, S. K.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVII, 2023, 12367
  • [8] Common-Path Optical Coherence Tomography Using a Conical-Frustum-Tip Fiber Probe
    Kim, Ji-hyun
    Han, Jae-Ho
    Jeong, Jichai
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2014, 20 (02)
  • [9] Tissue characterization using axicon probe-assisted common-path optical coherence tomography
    Gupta, Pooja
    Vairagi, Kaushal
    Sharma, Vishal
    Prasad, Kaushal Kishore
    Mondal, Samirk
    OPTICS EXPRESS, 2024, 32 (11): : 20194 - 20206
  • [10] Fourier Domain Common-Path Optical Coherence Tomography with a Conduit Fiber Bundle Probe
    Han, Jae-Ho
    Liu, Xuan
    Song, Chul Gyu
    Kang, Jin U.
    2009 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1AND 2, 2009, : 205 - 206