Direct analysis of six antibiotics in wastewater samples using rapid high-performance liquid chromatography coupled with diode array detector: A chemometric study towards green analytical chemistry

被引:38
作者
Vosough, Maryam [1 ]
Rashvand, Masourneh [1 ]
Esfahani, Hadi M. [1 ]
Kargosha, Kazem [1 ]
Salemi, Amir [2 ]
机构
[1] Chem & Chem Engn Res Ctr Iran, Tehran, Iran
[2] Shahid Beheshti Univ, Environm Sci Res Inst, GC, Tehran, Iran
基金
美国国家科学基金会;
关键词
Antibiotics; Direct analysis; HPLC-DAD; Second-order calibration; Wastewater; MULTIVARIATE CURVE-RESOLUTION; TRILINEAR DECOMPOSITION ALGORITHM; PARTIAL LEAST-SQUARES; HPLC-DAD; 2ND-ORDER CALIBRATION; QUANTITATIVE-DETERMINATION; RESIDUAL BILINEARIZATION; FLUORESCENCE DETECTION; MASS-SPECTROMETRY; LC-MS;
D O I
10.1016/j.talanta.2014.12.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a rapid HPLC-DAD method has been developed for the analysis of six antibiotics (amoxicillin, metronidazole, sulfamethoxazole, ofloxacine, sulfadiazine and sulfamerazine) in the sewage treatment plant influent and effluent samples. Decreasing the chromatographic run time to less than 4 min as well as lowering the cost per analysis, were achieved through direct injection of the samples into the HPLC system followed by chemometric analysis. The problem of the complete separation of the analytes from each other and/or from the matrix ingredients was resolved as a posteriori. The performance of MCR/ALS and U-PLS/RBL, as second-order algorithms, was studied and comparable results were obtained from implication of these modeling methods. It was demonstrated that the proposed methods could be used promisingly as green analytical strategies for detection and quantification of the targeted pollutants in wastewater samples while avoiding the more complicated high cost instrumentations. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 17
页数:11
相关论文
共 60 条
[1]   Analytical Figures of Merit for Partial Least-Squares Coupled to Residual Multilinearization [J].
Allegrini, Franco ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2012, 84 (24) :10823-10830
[2]   ChroMATHography: Solving Chromatographic Issues with Mathematical Models and Intuitive Graphics [J].
Amigo, Jose Manuel ;
Skov, Thomas ;
Bro, Rasmus .
CHEMICAL REVIEWS, 2010, 110 (08) :4582-4605
[3]   Comprehensive analysis of chromatographic data by using PARAFAC2 and principal components analysis [J].
Amigo, Jose Manuel ;
Popielarz, Marta J. ;
Callejon, Raquel M. ;
Morales, Maria L. ;
Troncoso, Ana M. ;
Petersen, Mikael A. ;
Toldam-Andersen, Torben B. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) :4422-4429
[4]  
[Anonymous], 1993, 1 EURACHEM, V25
[5]   A review on second- and third-order multivariate calibration applied to chromatographic data [J].
Arancibia, Juan A. ;
Damiani, Patricia C. ;
Escandar, Graciela M. ;
Ibanez, Gabriela A. ;
Olivieri, Alejandro C. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 910 :22-30
[6]   Comparison of the occurrence of antibiotics in four full-scale wastewater treatment plants with varying designs and operations [J].
Batt, Angela L. ;
Kim, Sungpyo ;
Aga, Diana S. .
CHEMOSPHERE, 2007, 68 (03) :428-435
[7]   Sensitivity Equation for Quantitative Analysis with Multivariate Curve Resolution-Alternating Least-Squares: Theoretical and Experimental Approach [J].
Bauza, Maria C. ;
Ibanez, Gabriela A. ;
Tauler, Roma ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2012, 84 (20) :8697-8706
[8]   THEORY OF ANALYTICAL-CHEMISTRY [J].
BOOKSH, KS ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :A782-A791
[9]   Time-alignment of bidimensional chromatograms in the presence of uncalibrated interferences using parallel factor analysis Application to multi-component determinations using liquid-chromatography with spectrofluorimetric detection [J].
Bortolato, S. A. ;
Arancibia, J. A. ;
Escandar, G. M. ;
Olivieri, A. C. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2010, 101 (01) :30-37
[10]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171