Exergy analysis of the flue gas pre-dried lignite-fired power system based on the boiler with open pulverizing system

被引:47
作者
Han, Xiaoqu [1 ]
Liu, Ming [1 ]
Wu, Kaili [1 ]
Chen, Weixiong [1 ]
Xiao, Feng [2 ]
Yan, Junjie [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
[2] China Power Engn Consulting Grp Corp, Northeast Elect Power Design Inst, Changchun 130021, Peoples R China
基金
中国国家自然科学基金;
关键词
Exergy analysis; Flue gas pre-drying; Lignite; Open pulverizing system; Simulation; WASTE HEAT-RECOVERY; THERMODYNAMIC ANALYSIS; PERFORMANCE ANALYSES; GENERATION SYSTEM; PLANT; CYCLE; OPTIMIZATION; DESIGN; ENERGY; INTEGRATION;
D O I
10.1016/j.energy.2016.03.047
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with an exergetic analysis of the flue gas pre-dried lignite-fired power system (FPLPS) based on the boiler with open pulverizing system (OPSB) to explore the energy-saving potential of the FPLPS. A steady-state simulation was performed to obtain thermodynamic properties of process streams in a 600 MW unit. Results indicated that the plant efficiency of the FPLPS was relatively 3.42% higher than that of the conventional lignite -fired power system (CLPS). The improvement benefited from the integration of the flue gas dryer with the OPS, in which the dryer exhaust gas was separated from coal powders and prevented from recycling in the furnace. Consequently, the exergy destruction in the combustion process was reduced by 232%-pts for increased flame temperature, and the exergy loss of the boiler exhaust gas was reduced by 0.68%-pts for decreased temperature. Moreover, the dryer exergy efficiency was only 20.20% due to considerable exergy destructions in the moisture evaporation and the mixing of drying agents. The proposed retrofitting option by extracting cold flue gas from the economizer outlet could increase the plant efficiency by 0.33% relatively. Finally, attempts were made to examine the influence of varying pre-drying parameters on system performances. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:285 / 300
页数:16
相关论文
共 49 条
  • [1] Energy and exergy analysis of a super critical thermal power plant at various load conditions under constant and pure sliding pressure operation
    Adibhatla, Sairam
    Kaushik, S. C.
    [J]. APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 51 - 65
  • [2] A review on exergy analysis of drying processes and systems
    Aghbashlo, Mortaza
    Mobli, Hossein
    Rafiee, Shahin
    Madadlou, Ashkan
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 22 : 1 - 22
  • [3] Exergy, exergoeconomic and environmental analyses and evolutionary algorithm based multi-objective optimization of combined cycle power plants
    Ahmadi, Pouria
    Dincer, Ibrahim
    Rosen, Marc A.
    [J]. ENERGY, 2011, 36 (10) : 5886 - 5898
  • [4] Exergoenvironmental analysis and optimization of a cogeneration plant system using Multimodal Genetic Algorithm (MGA)
    Ahmadi, Pouria
    Dincer, Ibrahim
    [J]. ENERGY, 2010, 35 (12) : 5161 - 5172
  • [5] [Anonymous], TOPMERET MOD TECHN H
  • [6] Thermodynamic analysis and comparison of retrofitting pre-drying concepts at existing lignite power plants
    Atsonios, Konstantinos
    Violidakis, Ioannis
    Agraniotis, Michalis
    Grammelis, Panagiotis
    Nikolopoulos, Nikos
    Kakaras, Emmanuel
    [J]. APPLIED THERMAL ENGINEERING, 2015, 74 : 165 - 173
  • [7] Bejan A, 1982, J APPL MEH, V50
  • [8] Burnard K., 2011, Information Paper
  • [9] Second law analysis of a waste heat recovery based power generation system
    Butcher, C. J.
    Reddy, B. V.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (11-12) : 2355 - 2363
  • [10] The exergy and energy level analysis of a combined cooling, heating and power system driven by a small scale gas turbine at off design condition
    Chen, Qiang
    Han, Wei
    Zheng, Jian-jiao
    Sui, Jun
    Jin, Hong-guang
    [J]. APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 590 - 602