Development and evaluation of a monoxide-based flexible skin dosimeter for radiotherapy at photon energies

被引:1
作者
Yang, S. W. [1 ]
Han, M. J. [1 ]
Park, S. K. [2 ]
Chung, J. B. [3 ]
Yu, T. S. [4 ]
Rah, J. E. [5 ]
Kim, J. K. [6 ]
Lee, M. W. [6 ]
Kim, J. Y. [4 ]
机构
[1] Inje Univ, Coll Med, Dept Radiat Oncol, Bokji Ro 75, Busan, South Korea
[2] Inje Univ, Busan Paik Hosp, Dept Radiat Oncol, Bokji Ro 75, Busan, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Radiat Oncol, 82 Gumi Ro 173, Seongnam Si, Gyeonggi Do, South Korea
[4] Dongnam Inst Radiol & Med Sci, Dept Radiat Oncol, 40 Jwadong Gil, Busan, South Korea
[5] Hanyang Univ, Coll Med, Myongji Hosp, Dept Radiat Oncol, 55 Hwaseo Ro 14th St, Goyang Si, Gyeonggi Do, South Korea
[6] Dongnam Inst Radiol & Med Sci, Res Ctr, 40 Jwadong Gil, Busan, South Korea
基金
新加坡国家研究基金会;
关键词
Radiotherapy concepts; Dosimetry concepts and apparatus; Radiation damage to detector materials (solid state); X-RAY-DETECTOR;
D O I
10.1088/1748-0221/16/07/P07056
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Radiation therapy uses high-energy radiation that can cause various side effects depending on the patient's exposure. In particular, the radiation exposure of the skin to reach the target volume produces side effects. Therefore, side effects as skin damage can be reduced during clinical trials using various skin dosimeters such as films and glass detectors to determine the skin dose exposure. However, accurately measuring the doses using these dosimeters is challenging due to human body curvature. In this study, a flexible skin dosimeter was developed using the photoconductor materials mercury oxide (HgO) and lead oxide (PbO). The performance of the proposed dosimeter was evaluated by measuring reproducibility, linearity, dose rate independence according to dose, and percent depth dose (PDD) at photon energy beam. The results showed that the flexible skin dosimeter using HgO material has high applicability as a skin dosimeter due to its stability compared to PbO. The results also provided useful insights for the radiation therapy field, particularly in areas where radiation measurement is difficult, depending on the human curvature. The proposed apparatus could serve in various radiation detection areas as a flexible, functional material.
引用
收藏
页数:11
相关论文
共 22 条
  • [21] Sung SY., 2017, Ther Radiol Oncol, V1, P1, DOI [10.21037/tro.2017.11.01, DOI 10.21037/TRO.2017.11.01]
  • [22] Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer
    Wolff, Dirk
    Stieler, Florian
    Welzel, Grit
    Lorenz, Friedlieb
    Abo-Madyan, Yasser
    Mai, Sabine
    Herskind, Carsten
    Polednik, Martin
    Steil, Volker
    Wenz, Frederik
    Lohr, Frank
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) : 226 - 233