Energy, Exergy, Environmental (3E) and Parametric Assessment of a Triple-Pressure Reheat Combined-Cycle Power Plant

被引:12
|
作者
Jamnani, Mohammadreza Babaei [1 ]
Ting, David S-K [1 ]
Carriveau, Rupp [1 ]
Kardgar, Amin [2 ]
机构
[1] Univ Windsor, Turbulence & Energy Lab, Windsor, ON N9B 3P4, Canada
[2] Univ Mazandaran, Dept Mech Engn, POB 416, Babolsar 4741613534, Mazandaran, Iran
来源
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME | 2021年 / 143卷 / 11期
关键词
combined-cycle power plant; exergy; adiabatic flame temperature; efficiency; combustion chamber; environmental analysis; air emissions from fossil fuel combustion; energy conversion; systems; energy storage systems; energy systems analysis; heat energy generation; storage; transfer; power (co-) generation; MULTIOBJECTIVE OPTIMIZATION; PERFORMANCE; HEAT; HRSG;
D O I
10.1115/1.4049738
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, energy, exergy, and environmental (3E) assessments have been conducted on a proposed combined-cycle power plant (CCPP) with three pressure levels of the HRSG and reheating process. 3E design approaches cross-link mechano-electric and environmental objectives. Herewith, the suggested combined-cycle is formed by a gas unit, condenser, steam turbines, triple-pressure heat recovery steam generator (HRSG) and also utilizes reheat facilities and auxiliary components. It is observed that more than 56% of total exergy destruction occurs in the combustor, followed by HRSG (15.29%), steam turbines (roughly 15.02%), gas turbine (8.93%), air compressor (1.79%), and condenser (0.66%). A parametric study is also presented that examines the sensitivity of performance indicators to various environmental states, steam pressures, pinch points, and steam mass flow rates. Moreover, it is presented that the implementation of Siemens SGT-100-1S over other GT configurations can considerably reduce deficiency of the overall cycle. The effects of each contaminant mass flowrate (NOx, CO, UHC, and CO2) and adiabatic flame temperature (AFT) are also studied when the gas unit operates under partial power and incomplete combustion conditions. In conclusion, a number of potential causes of irreversibilities and corrective optimization guidance are offered for each main equipment of the CCPP.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Sensitivity analysis of combined cycle parameters on exergy, economic, and environmental of a power plant
    M. A. Javadi
    S. Hoseinzadeh
    R. Ghasemiasl
    P. S. Heyns
    A. J. Chamkha
    Journal of Thermal Analysis and Calorimetry, 2020, 139 : 519 - 525
  • [42] Energy-exergy analysis of gas turbine cycle in a combined cycle power plant
    Hacihafizoglu, Oktay
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2011, 27 (01): : 123 - 138
  • [43] An innovative approach for utilizing waste heat of a triple-pressure cogeneration combined cycle power plant by employing TRR method and thermodynamic analysis
    Mohtaram, Soheil
    Aryanfar, Yashar
    Ghazy, Ahmed
    Wu, Weidong
    Kaaniche, Khaled
    Alcaraz, Jorge Luis Garcia
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 49
  • [44] Energy, exergy and advanced exergy analyses on Garri 1 combined cycle power plant of Sudan
    Omara, Adil A.M.
    Mohammedali, Abubaker A.M.
    Dhivagar, R.
    International Journal of Thermofluids, 2024, 24
  • [45] 4E analysis and tri-objective optimization of a triple-pressure combined cycle power plant  with combustion chamber steam injection to control NOx emission
    Iman Fakhari
    Parsa Behinfar
    Farhang Raymand
    Amirreza Azad
    Pouria Ahmadi
    Ehsan Houshfar
    Mehdi Ashjaee
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 1317 - 1333
  • [46] 4E analysis and tri-objective optimization of a triple-pressure combined cycle power plant with combustion chamber steam injection to control NOx emission
    Fakhari, Iman
    Behinfar, Parsa
    Raymand, Farhang
    Azad, Amirreza
    Ahmadi, Pouria
    Houshfar, Ehsan
    Ashjaee, Mehdi
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (03) : 1317 - 1333
  • [47] Energy efficiency assessment of fixed asset investment projects - A case study of a Shenzhen combined-cycle power plant
    Li Yingjian
    Abakr, Yousif A.
    Qi, Qiu
    You Xinkui
    Zhou Jiping
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 59 : 1195 - 1208
  • [48] Exergoeconomic Evaluation of a Two-Pressure Level Fired Combined-Cycle Power Plant
    Khanmohammadi, Shoaib
    Azimian, Ahmad Reza
    JOURNAL OF ENERGY ENGINEERING, 2015, 141 (03)
  • [49] Exergy assessment of air film blade cooled combined power cycle plant
    Tara Chand, Vadlamudi
    Ravindra, Kommineni
    Bala Prasad, Katuru
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2020, 41 (09) : 994 - 1006
  • [50] Exergy assessment of air film blade cooled combined power cycle plant
    Tara Chand, Vadlamudi
    Ravindra, Kommineni
    Bala Prasad, Katuru
    International Journal of Ambient Energy, 2020, 41 (09): : 994 - 1006