A microdialysis fibre based sampler for flow injection analysis: Determination of L-lactate in biofluids by an electrochemically synthesised bilayer membrane based biosensor

被引:39
作者
Palmisano, F [1 ]
Centonze, D [1 ]
Quinto, M [1 ]
Zambonin, PG [1 ]
机构
[1] UNIV BARI,DIPARTMENTO CHIM,I-70126 BARI,ITALY
关键词
L-lactate; microdialysis; biosensors; flow injection analysis;
D O I
10.1016/0956-5663(96)82737-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A microdialysis fibre based, low volume sampler is described which can be used in flow injection analysis (FIA) when an on-line dilution of the sample and/or removal of high molecular weight interferents is required. This device used in combination with a lactate amperometric biosensor based on lactate oxidase electrochemically immobilised in a bilayer membrane of poly(o-phenylendiamine) and overoxidized poly(pyrrole) permits the extension of the linear range of response up to 10 mM lactate. Combining microdialysis sampling with FIA and amperometric detection at an interference-free and fast-response biosensor, lactate determination in complex media such as serum, milk and yoghurt can be easily achieved with a high sample throughput and no sample pre-treatment.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 17 条
[1]  
[Anonymous], 1991, MICRODIALYSIS NEUROS
[2]   INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM [J].
CENTONZE, D ;
GUERRIERI, A ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09) :729-733
[3]  
CENTONZE D, 1992, ANN CHIM-ROME, V82, P219
[4]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[5]   A NEEDLE-TYPE ENZYME-BASED LACTATE SENSOR FOR IN-VIVO MONITORING [J].
HU, YB ;
ZHANG, YN ;
WILSON, GS .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :503-511
[6]   SAMPLING LIVING SYSTEMS USING MICRODIALYSIS PROBES [J].
LUNTE, CE ;
SCOTT, DO ;
KISSINGER, PT .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :A773-+
[7]   ASCORBIC-ACID OXIDATION AT POLYPYRROLE-COATED ELECTRODES [J].
LYONS, MEG ;
BREEN, W ;
CASSIDY, J .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1991, 87 (01) :115-123
[8]   GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM [J].
MALITESTA, C ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
ANALYTICAL CHEMISTRY, 1990, 62 (24) :2735-2740
[9]   ON LINE CONTINUOUS MONITORING OF BLOOD LACTATE IN MEN BY A WEARABLE DEVICE BASED UPON AN ENZYMATIC AMPEROMETRIC LACTATE SENSOR [J].
MEYERHOFF, C ;
BISCHOF, F ;
MENNEL, FJ ;
STERNBERG, F ;
BICAN, J ;
PFEIFFER, EF .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) :409-414
[10]  
MILLER JC, 1984, STATISTICS ANAL CHEM, pCH3