A microdialysis fibre based sampler for flow injection analysis: Determination of L-lactate in biofluids by an electrochemically synthesised bilayer membrane based biosensor

被引:39
作者
Palmisano, F [1 ]
Centonze, D [1 ]
Quinto, M [1 ]
Zambonin, PG [1 ]
机构
[1] UNIV BARI,DIPARTMENTO CHIM,I-70126 BARI,ITALY
关键词
L-lactate; microdialysis; biosensors; flow injection analysis;
D O I
10.1016/0956-5663(96)82737-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A microdialysis fibre based, low volume sampler is described which can be used in flow injection analysis (FIA) when an on-line dilution of the sample and/or removal of high molecular weight interferents is required. This device used in combination with a lactate amperometric biosensor based on lactate oxidase electrochemically immobilised in a bilayer membrane of poly(o-phenylendiamine) and overoxidized poly(pyrrole) permits the extension of the linear range of response up to 10 mM lactate. Combining microdialysis sampling with FIA and amperometric detection at an interference-free and fast-response biosensor, lactate determination in complex media such as serum, milk and yoghurt can be easily achieved with a high sample throughput and no sample pre-treatment.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 17 条
  • [1] [Anonymous], 1991, MICRODIALYSIS NEUROS
  • [2] INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM
    CENTONZE, D
    GUERRIERI, A
    MALITESTA, C
    PALMISANO, F
    ZAMBONIN, PG
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09): : 729 - 733
  • [3] CENTONZE D, 1992, ANN CHIM-ROME, V82, P219
  • [4] ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS
    FOULDS, NC
    LOWE, CR
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 : 1259 - 1264
  • [5] A NEEDLE-TYPE ENZYME-BASED LACTATE SENSOR FOR IN-VIVO MONITORING
    HU, YB
    ZHANG, YN
    WILSON, GS
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 503 - 511
  • [6] SAMPLING LIVING SYSTEMS USING MICRODIALYSIS PROBES
    LUNTE, CE
    SCOTT, DO
    KISSINGER, PT
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (15) : A773 - +
  • [7] ASCORBIC-ACID OXIDATION AT POLYPYRROLE-COATED ELECTRODES
    LYONS, MEG
    BREEN, W
    CASSIDY, J
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1991, 87 (01): : 115 - 123
  • [8] GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM
    MALITESTA, C
    PALMISANO, F
    TORSI, L
    ZAMBONIN, PG
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (24) : 2735 - 2740
  • [9] ON LINE CONTINUOUS MONITORING OF BLOOD LACTATE IN MEN BY A WEARABLE DEVICE BASED UPON AN ENZYMATIC AMPEROMETRIC LACTATE SENSOR
    MEYERHOFF, C
    BISCHOF, F
    MENNEL, FJ
    STERNBERG, F
    BICAN, J
    PFEIFFER, EF
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) : 409 - 414
  • [10] MILLER JC, 1984, STATISTICS ANAL CHEM, pCH3