Novel Pedicle Screw and Plate System Provides Superior Stability in Unilateral Fixation for Minimally Invasive Transforaminal Lumbar Interbody Fusion: An In Vitro Biomechanical Study

被引:5
作者
Li, Jie [1 ]
Xiao, Hong [1 ]
Zhu, Qingan [2 ]
Zhou, Yue [1 ]
Li, Changqing [1 ]
Liu, Huan [1 ]
Huang, Zhiping [2 ]
Shang, Jin [1 ]
机构
[1] Third Mil Med Univ, Xinqiao Hosp, Dept Orthoped, Chongqing, Peoples R China
[2] Southern Med Univ, Nanfang Hosp, Dept Orthopaed & Spinal Surg, Guangzhou, Guangdong, Peoples R China
关键词
POSTERIOR; SPINES;
D O I
10.1371/journal.pone.0123134
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body. Methods Seven fresh calf lumbar spines (L3-L6) were tested. Flexion/extension, lateral bending, and axial rotation were induced by pure moments of +/- 5.0 Nm and the range of motion (ROM) was recorded. Strain gauges were instrumented at L4 and L5 vertebral body to record the strain distribution under flexion and lateral bending (LB). After intact kinematic analysis, a right sided TLIF was performed at L4-L5. Then each specimen was tested for the following constructs: unilateral pedicle screw and rod (UR); unilateral pedicle screw and plate (UP); UR and transfacet pedicle screw (TFS); UP and TFS; UP and UR. Results All instrumented constructs significantly reduced ROM in all motion compared with the intact specimen, except the UR construct in axial rotation. Unilateral fixation (UR or UP) reduced ROM less compared with the bilateral fixation (UP/UR+TFS, UP+UR). The plate system resulted in more reduction in ROM compared with the rod system, especially in axial rotation. UP construct provided more stability in axial rotation compared with UR construct. The strain distribution on the left and right side of L4 vertebral body was significantly different from UR and UR+TFS construct under flexion motion. The strain distribution on L4 vertebral body was significantly influenced by different fixation constructs. Conclusions The novel plate could provide sufficient segmental stability in axial rotation. The UR construct exhibits weak stability and asymmetrical strain distribution in fusion segment, while the UP construct is a good alternative choice for unilateral posterior fixation of MI-TLIF.
引用
收藏
页数:13
相关论文
共 31 条
[21]   Minimally invasive anterior lumbar interbody fusion followed by percutaneous pedicle screw fixation for isthmic spondylolisthesis: minimum 5-year follow-up [J].
Kim, Jin-Sung ;
Choi, Won Gyu ;
Lee, Sang-Ho .
SPINE JOURNAL, 2010, 10 (05) :404-409
[22]   Mini-Transforaminal Lumbar Interbody Fusion Versus Anterior Lumbar Interbody Fusion Augmented by Percutaneous Pedicle Screw Fixation A Comparison of Surgical Outcomes in Adult Low-grade Isthmic Spondylolisthesis [J].
Kim, Jin-Sung ;
Kang, Byung-Uk ;
Lee, Sang-Ho ;
Jung, Byungjoo ;
Choi, Young-Geun ;
Jeon, Sang Hyeop ;
Lee, Ho Yeon .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (02) :114-121
[23]   Minimally Invasive Transforaminal Interbody Fusion Versus Microdiscectomy Without Fusion for Recurrent Lumbar Disk Herniation: A Prospective Comparative Study [J].
D'Oria, Salvatore ;
Giraldi, David ;
Murrone, Domenico ;
Salamone, Giuseppe Giovanni ;
Tomatis, Alberto ;
Colamaria, Antonio ;
Carbone, Francesco ;
Rossitto, Martina ;
Fanelli, Vincenzo .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2023, 31 (22) :1157-1164
[24]   Minimally invasive versus open transforaminal lumbar interbody fusion: a prospective, controlled observational study of short-term outcome [J].
Hartmann, Sebastian ;
Lang, Anna ;
Lener, Sara ;
Abramovic, Anto ;
Grassner, Lukas ;
Thome, Claudius .
NEUROSURGICAL REVIEW, 2022, 45 (05) :3417-3426
[25]   Minimally invasive versus traditional open transforaminal lumbar interbody fusion for the treatment of low-grade degenerative spondylolisthesis: a retrospective study [J].
Qin, Rongqing ;
Wu, Tong ;
Liu, Hongpeng ;
Zhou, Bing ;
Zhou, Pin ;
Zhang, Xing .
SCIENTIFIC REPORTS, 2020, 10 (01)
[26]   A comparison of the influence of three different lumbar interbody fusion approaches on stress in the pedicle screw fixation system: Finite element static and vibration analyses [J].
Fan, Wei ;
Guo, Li-Xin .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (03)
[27]   A novel surgical technique in transforaminal lumbar interbody fusion by the bone graft delivery device: evaluation of therapeutic effect in patients with minimally invasive spine surgery [J].
Yang, Kai-shun ;
Chen, Chih-Wei ;
Yau, Ru-Bin ;
Liang, Huang-Chien ;
Ko, Ching-Chung ;
Kuo, Jinn-Rung ;
Chio, Chung-Ching ;
Lim, Sher-Wei .
BMC SURGERY, 2022, 22 (01)
[28]   Facet Joint Fixation and Anterior, Direct Lateral, and Transforaminal Lumbar Interbody Fusions for Treatment of Degenerative Lumbar Disc Diseases: Retrospective Cohort Study of a New Minimally Invasive Technique [J].
Belykh, Evgenii ;
Kalinin, Andrey A. ;
Martirosyan, Nikolay L. ;
Kerimbayev, Talgat ;
Theodore, Nicholas ;
Preul, Mark C. ;
Byvaltsev, Vadim A. .
WORLD NEUROSURGERY, 2018, 114 :E959-E968
[29]   Short-Term Effect of Unilateral Pedicle Screw Fixed Intervertebral Fusion in Treatment of Degenerative Disc Disease Via MAST QUADRANT Minimally Invasive System [J].
Chen, Xuanhuang ;
Wu, Changfu ;
Lin, Haibin ;
Zhang, Guodong ;
Li, Rongyi .
CELL BIOCHEMISTRY AND BIOPHYSICS, 2014, 70 (01) :195-199
[30]   Effects of open and minimally invasive Transforaminal Lumbar Interbody Fusion (TLIF) surgical techniques on mechanical behaviour of fused L3-L4 FSU: A comparative finite element study [J].
Pradeep, Kishore ;
Pal, Bidyut .
MEDICAL ENGINEERING & PHYSICS, 2024, 123