Novel Pedicle Screw and Plate System Provides Superior Stability in Unilateral Fixation for Minimally Invasive Transforaminal Lumbar Interbody Fusion: An In Vitro Biomechanical Study

被引:4
作者
Li, Jie [1 ]
Xiao, Hong [1 ]
Zhu, Qingan [2 ]
Zhou, Yue [1 ]
Li, Changqing [1 ]
Liu, Huan [1 ]
Huang, Zhiping [2 ]
Shang, Jin [1 ]
机构
[1] Third Mil Med Univ, Xinqiao Hosp, Dept Orthoped, Chongqing, Peoples R China
[2] Southern Med Univ, Nanfang Hosp, Dept Orthopaed & Spinal Surg, Guangzhou, Guangdong, Peoples R China
关键词
POSTERIOR; SPINES;
D O I
10.1371/journal.pone.0123134
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body. Methods Seven fresh calf lumbar spines (L3-L6) were tested. Flexion/extension, lateral bending, and axial rotation were induced by pure moments of +/- 5.0 Nm and the range of motion (ROM) was recorded. Strain gauges were instrumented at L4 and L5 vertebral body to record the strain distribution under flexion and lateral bending (LB). After intact kinematic analysis, a right sided TLIF was performed at L4-L5. Then each specimen was tested for the following constructs: unilateral pedicle screw and rod (UR); unilateral pedicle screw and plate (UP); UR and transfacet pedicle screw (TFS); UP and TFS; UP and UR. Results All instrumented constructs significantly reduced ROM in all motion compared with the intact specimen, except the UR construct in axial rotation. Unilateral fixation (UR or UP) reduced ROM less compared with the bilateral fixation (UP/UR+TFS, UP+UR). The plate system resulted in more reduction in ROM compared with the rod system, especially in axial rotation. UP construct provided more stability in axial rotation compared with UR construct. The strain distribution on the left and right side of L4 vertebral body was significantly different from UR and UR+TFS construct under flexion motion. The strain distribution on L4 vertebral body was significantly influenced by different fixation constructs. Conclusions The novel plate could provide sufficient segmental stability in axial rotation. The UR construct exhibits weak stability and asymmetrical strain distribution in fusion segment, while the UP construct is a good alternative choice for unilateral posterior fixation of MI-TLIF.
引用
收藏
页数:13
相关论文
共 31 条
[11]   Biomechanical comparison of unilateral and bilateral pedicle screws fixation for transforaminal lumbar interbody fusion after decompressive surgery - a finite element analysis [J].
Chen, Shih-Hao ;
Lin, Shang-Chih ;
Tsai, Wen-Chi ;
Wang, Chih-Wei ;
Chao, Shih-Heng .
BMC MUSCULOSKELETAL DISORDERS, 2012, 13
[12]   RETRACTED: Minimally Invasive Unilateral vs. Bilateral Pedicle Screw Fixation and Lumbar Interbody Fusion in Treatment of Multi-Segment Lumbar Degenerative Disorders (Retracted Article) [J].
Liu, Xiaoyang ;
Li, Guangrun ;
Wang, Jiefeng ;
Zhang, Heqing .
MEDICAL SCIENCE MONITOR, 2015, 21 :3652-3657
[13]   Unilateral versus bilateral pedicle screw fixation in lumbar interbody fusion: A meta-analysis of complication and fusion rate [J].
Yuan, Chaoqun ;
Chen, Kai ;
Zhang, Hailong ;
Zhang, Hanyu ;
He, Shisheng .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 117 :28-32
[14]   Unilateral versus Bilateral Pedicle Screw Fixation Combined with Transforaminal Lumbar Interbody Fusion for the Treatment of Low Lumbar Degenerative Disc Diseases: Analysis of Clinical and Radiographic Results [J].
Chen, De-jian ;
Yao, Cong ;
Song, Quanwei ;
Tang, Benyu ;
Liu, Xuqiang ;
Zhang, Bin ;
Dai, Min ;
Nie, Tao ;
Wan, Zongmiao .
WORLD NEUROSURGERY, 2018, 115 :E516-E522
[15]   Comparing oblique lumbar interbody fusion with lateral screw fixation and percutaneous endoscopic transforaminal discectomy (OLIF-PETD) and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for the treatment of lumbar disc herniation complicated with lumbar instability [J].
Deng, Chen ;
Feng, Haoyu ;
Ma, Xun ;
Chen, Chen ;
Mei, Jun ;
Sun, Lin .
BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
[16]   Comparison of unilateral versus bilateral pedicle screw fixation in transforaminal lumbar interbody fusion: a systematic review and meta-analysis of twelve randomized controlled trials [J].
Ren, Siying ;
Hu, Yan .
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (09) :17113-17127
[17]   Slippage reduction of lumbar spondylolisthesis using percutaneous pedicle screw with reduction fixation system after interbody fusion: A comparison with traditional open fusion and pedicle screw fixation [J].
Heo, Dong-Hwa ;
Jang, Jae-Won ;
Lee, Jung-Kil ;
Park, Choon-Keun .
JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 67 :156-162
[18]   Comparison of Minimally Invasive and Open Transforaminal Lumbar Interbody Fusion for Lumbar Disc Herniation: A Retrospective Cohort Study [J].
Zhao, Jinqiu ;
Zhang, Shujun ;
Li, Xiaosong ;
He, Bin ;
Ou, Yunsheng ;
Jiang, Dianming .
MEDICAL SCIENCE MONITOR, 2018, 24 :8693-8698
[19]   Effect of Pedicle Screw Fixation on Adjacent Segments in Osteoporotic Spine Following Transforaminal Lumbar Interbody Fusion Under Whole Body Vibration [J].
Yuan, Xin ;
Li, Yixuan ;
Chen, Qian ;
Zeng, Qiuhong ;
Pou, Kuokchon ;
Wong, Hungho ;
Tang, Shujie .
WORLD NEUROSURGERY, 2022, 161 :E523-E530
[20]   Minimally invasive unilateral pedicle screws and a translaminar facet screw fixation and interbody fusion for treatment of single-segment lower lumbar vertebral disease: surgical technique and preliminary clinical results [J].
Huang, Peng ;
Wang, Yiguo ;
Xu, Jiao ;
Xiao, Bo ;
Liu, Jianheng ;
Che, Luyang ;
Mao, Keya .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12