Novel Pedicle Screw and Plate System Provides Superior Stability in Unilateral Fixation for Minimally Invasive Transforaminal Lumbar Interbody Fusion: An In Vitro Biomechanical Study

被引:4
|
作者
Li, Jie [1 ]
Xiao, Hong [1 ]
Zhu, Qingan [2 ]
Zhou, Yue [1 ]
Li, Changqing [1 ]
Liu, Huan [1 ]
Huang, Zhiping [2 ]
Shang, Jin [1 ]
机构
[1] Third Mil Med Univ, Xinqiao Hosp, Dept Orthoped, Chongqing, Peoples R China
[2] Southern Med Univ, Nanfang Hosp, Dept Orthopaed & Spinal Surg, Guangzhou, Guangdong, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 03期
关键词
POSTERIOR; SPINES;
D O I
10.1371/journal.pone.0123134
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body. Methods Seven fresh calf lumbar spines (L3-L6) were tested. Flexion/extension, lateral bending, and axial rotation were induced by pure moments of +/- 5.0 Nm and the range of motion (ROM) was recorded. Strain gauges were instrumented at L4 and L5 vertebral body to record the strain distribution under flexion and lateral bending (LB). After intact kinematic analysis, a right sided TLIF was performed at L4-L5. Then each specimen was tested for the following constructs: unilateral pedicle screw and rod (UR); unilateral pedicle screw and plate (UP); UR and transfacet pedicle screw (TFS); UP and TFS; UP and UR. Results All instrumented constructs significantly reduced ROM in all motion compared with the intact specimen, except the UR construct in axial rotation. Unilateral fixation (UR or UP) reduced ROM less compared with the bilateral fixation (UP/UR+TFS, UP+UR). The plate system resulted in more reduction in ROM compared with the rod system, especially in axial rotation. UP construct provided more stability in axial rotation compared with UR construct. The strain distribution on the left and right side of L4 vertebral body was significantly different from UR and UR+TFS construct under flexion motion. The strain distribution on L4 vertebral body was significantly influenced by different fixation constructs. Conclusions The novel plate could provide sufficient segmental stability in axial rotation. The UR construct exhibits weak stability and asymmetrical strain distribution in fusion segment, while the UP construct is a good alternative choice for unilateral posterior fixation of MI-TLIF.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study
    Ambati, Divya V.
    Wright, Edward K., Jr.
    Lehman, Ronald A., Jr.
    Kang, Daniel G.
    Wagner, Scott C.
    Dmitriev, Anton E.
    SPINE JOURNAL, 2015, 15 (08): : 1812 - 1822
  • [2] Pedicle screw fixation in minimally invasive transforaminal lumbar interbody fusion
    Luo, Peng
    Wu, Jia
    Mao, Guang-Yun
    NEUROSURGICAL FOCUS, 2014, 36 (06)
  • [3] Pedicle screw fixation in minimally invasive transforaminal lumbar interbody fusion Response
    Park, Jeong Yoon
    NEUROSURGICAL FOCUS, 2014, 36 (06)
  • [4] Unilateral versus bilateral percutaneous pedicle screw fixation in minimally invasive transforaminal lumbar interbody fusion
    Choi, Un Yong
    Park, Jeong Yoon
    Kim, Kyung Hyun
    Kuh, Sung Uk
    Chin, Dong Kyu
    Kim, Keun Su
    Cho, Yong Eun
    NEUROSURGICAL FOCUS, 2013, 35 (02)
  • [5] Minimally invasive transforaminal lumbar interbody fusion with unilateral pedicle screw fixation (UNILF): outcomes at 7 years
    Quentin Hamel
    Rémi Prebet
    Olivier Lucas
    Ghassan Hayek
    Henry-François Parent
    Audrey Angelliaume
    European Spine Journal, 2024, 33 : 356 - 360
  • [6] Minimally invasive transforaminal lumbar interbody fusion with unilateral pedicle screw fixation (UNILF): outcomes at 7 years
    Hamel, Quentin
    Prebet, Remi
    Lucas, Olivier
    Hayek, Ghassan
    Parent, Henry-Francois
    Angelliaume, Audrey
    EUROPEAN SPINE JOURNAL, 2024, 33 (01) : 356 - 360
  • [7] Minimally invasive transforaminal lumbar interbody fusion with ipsilateral pedicle screw and contralateral facet screw fixation
    Jang, JS
    Lee, SH
    JOURNAL OF NEUROSURGERY-SPINE, 2005, 3 (03) : 218 - 223
  • [8] Minimally Invasive Transforaminal Lumbar Interbody Fusion with Unilateral Pedicle Screw Fixation: Comparison between Primary and Revision Surgery
    Kang, Moo Sung
    Park, Jeong Yoon
    Kim, Kyung Hyun
    Kuh, Sung Uk
    Chin, Dong Kyu
    Kim, Keun Su
    Cho, Yong Eun
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [9] Minimally Invasive Unilateral Pedicle Screw Fixation and Lumbar Interbody Fusion for the Treatment of Lumbar Degenerative Disease
    Lin, Bin
    Xu, Yang
    He, Yong
    Zhang, Bi
    Lin, Qiuyan
    He, Mingchang
    ORTHOPEDICS, 2013, 36 (08) : E1071 - E1076
  • [10] Minimally invasive transforaminal lumbar interbody fusion with percutaneous navigated guidewireless lumbosacral pedicle screw fixation
    Chen, Kevin S.
    Park, Paul
    Neurosurgical Focus, 2016, 41