Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography

被引:0
|
作者
Jayarathna, Sandun [1 ]
Moktan, Hem [1 ]
Cho, Sang Hyun [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
来源
IEEE ACCESS | 2022年 / 10卷
关键词
Detectors; Collimators; Imaging; X-ray imaging; Image quality; Energy resolution; Economic indicators; Fluorescence; Nanoparticles; X-ray fluorescence; X-ray fluorescence computed tomography; CdTe detector; HEXITEC; gold nanoparticle; quantitative imaging; XFCT;
D O I
10.1109/ACCESS.2022.3210590
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as High-Energy X-ray Imaging Technology (HEXITEC), we performed quantitative imaging of gold nanoparticle (GNP) distribution in a small animal-sized phantom using our benchtop XFCT system. Owing to the upgraded detector component within our benchtop XFCT system, we were able to conduct this phantom imaging in an unprecedented manner by volumetric XFCT scans followed by XFCT image reconstruction in 3D. The current results showed that adoption of HEXITEC, in conjunction with a custom-made parallel-hole collimator, drastically reduced the XFCT scan time/dose. Compared with the previous work performed with our original benchtop XFCT system adopting a single crystal CdTe detector, the currently observed reduction was up to a factor of 5, while achieving comparable GNP detection limit under similar experimental conditions. Overall, we demonstrated, for the first time to the best our knowledge, the feasibility of benchtop XFCT imaging of small animal-sized objects containing biologically relevant GNP concentrations (on the order of 0.1 mg Au/cm3 or 100 parts-per-million/ppm), with the scan time (on the order of 1 minute)/ x-ray dose (on the order of 10 cGy) that are likely meeting the minimum requirements for routine preclinical imaging applications.
引用
收藏
页码:105074 / 105083
页数:10
相关论文
共 50 条
  • [1] Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging
    Jayarathna, Sandun
    Ahmed, Md Foiez
    O'ryan, Liam
    Moktan, Hem
    Cui, Yonggang
    Cho, Sang Hyun
    IEEE ACCESS, 2021, 9 : 49912 - 49919
  • [2] Benchtop x-ray fluorescence computed tomography (XFCT) imaging
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [3] Simple x-ray computed tomography system utilizing a cadmium telluride detector
    Sato, Eiichi
    Nomiya, Seiichiro
    Hitomi, Keitaro
    Onabe, Hideaki
    Shoji, Tadayoshi
    Tanaka, Etsuro
    Kawai, Toshiaki
    Inoue, Takashi
    Ogawa, Akira
    Sato, Shigehiro
    Ichimaru, Toshio
    Takayama, Kazuyoshi
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS IX, 2007, 6706
  • [4] Spectral X-ray computed tomography scanner using a cadmium telluride detector
    Sato, Eiichi
    Oda, Yasuyuki
    Yamaguchi, Satoshi
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Watanabe, Manabu
    Kusachi, Shinya
    RADIATION DETECTORS: SYSTEMS AND APPLICATIONS XVII, 2016, 9969
  • [5] Energy-discriminating X-ray computed tomography system utilizing a cadmium telluride detector
    Sato, Eiichi
    Abderyim, Purkhet
    Enomoto, Toshiyuki
    Watanabe, Manabu
    Hitomi, Keitaro
    Takahasi, Kiyomi
    Sato, Shigehiro
    Ogawae, Akira
    Onagawa, Jun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3) : 262 - 265
  • [6] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [7] Energy-discrimination x-ray computed tomography system utilizing a scanning cadmium-telluride detector
    Sato, Eiichi
    Abduraxit, Ablajan
    Enomoto, Toshiyuki
    Watanabe, Manabu
    Hitomi, Keitaro
    Takahashi, Kiyomi
    Sato, Shigehiro
    Ogawa, Akira
    Onagawa, Jun
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [8] Cone-beam x-ray fluorescence imaging using pixelated cadmium telluride photon-counting detector with pinhole collimator
    Shi, Junwei
    Hara, Daiki
    Schmidt, Ryder
    Tao, Wensi
    Dogana, Nesrin
    Ford, John Chetley
    Pollack, Alan
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [9] Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: A Monte Carlo study
    Manohar, Nivedh
    Jones, Bernard L.
    Cho, Sang Hyun
    MEDICAL PHYSICS, 2014, 41 (10)
  • [10] Demonstration of iodine K-edge imaging by use of an energy-discrimination X-ray computed tomography system with a cadmium telluride detector
    Abudurexiti A.
    Kameda M.
    Sato E.
    Abderyim P.
    Enomoto T.
    Watanabe M.
    Hitomi K.
    Tanaka E.
    Mori H.
    Kawai T.
    Takahashi K.
    Sato S.
    Ogawa A.
    Onagawa J.
    Radiological Physics and Technology, 2010, 3 (2) : 127 - 135