Gamma electron vertex imaging for in-vivo beam-range measurement in proton therapy: Experimental results

被引:7
作者
Kim, Chan Hyeong [1 ]
Lee, Han Rim [2 ]
Kim, Sung Hun [1 ]
Park, Jong Hoon [1 ]
Cho, Sungkoo [3 ]
Jung, Won Gyun [4 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[2] Korea Atom Energy Res Inst, Neutron Utilizat Technol Div, 111 Daedeok Daero 989beon Gil, Daejeon 34057, South Korea
[3] Samsung Med Ctr, Radiat Oncol, 81 Irwon Ro, Seoul 06351, South Korea
[4] Korean Inst Radiol & Med Sci, Heavy Ion Clin Res Div, Seoul 01812, South Korea
基金
新加坡国家研究基金会;
关键词
COMPTON CAMERA; VERIFICATION; SYSTEM; RAYS;
D O I
10.1063/1.5039448
中图分类号
O59 [应用物理学];
学科分类号
摘要
Proton therapy, thanks to the dose characteristics of the Bragg peak, according to which most of the radiation energy is delivered at the end of the beam with a very high dose gradient at the distal edge, can deliver a highly conformal radiation dose to the treatment volume. Currently, however, the benefit of this high dose gradient is not fully utilized in clinical practice due mainly to the dose-distribution uncertainty in the beam direction (i.e., the uncertainty of the beam range in the patient). In this paper, we present an imaging system based on gamma electron vertex imaging (GEVI), which is suitable for high-energy (1-30 MeV) gammas, and test its performance for therapeutic proton beams. GEVI images prompt gamma vertices, which are closely correlated with the dose distribution at the distal edge, by converting prompt gammas to electrons via Compton scattering and then tracking the recoiled electrons. Our experimental results show that the GEVI system can image the 2D vertices of the prompt gammas and, thus, can be utilized for the measurement of proton-beam ranges in patients. We believe, indeed, that GEVI makes possible real-time monitoring of in-vivo proton-beam ranges, whose utility significantly improves treatment effectiveness and enhances patient safety. We also expect that the GEVI system will find applications in other fields (e.g., gamma-ray astronomy, nuclear engineering, and high-energy physics) requiring high-energy-gamma (1-30 MeV) imaging. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 22 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Stochastic Image Reconstruction Method for Compton Camera
    Andreyev, Andriy
    Sitek, Arkadiusz
    Celler, Anna
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2985 - +
  • [3] Delaney TF., 2008, Proton and Charged Particle Radiotherapy
  • [4] MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM
    DEMPSTER, AP
    LAIRD, NM
    RUBIN, DB
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01): : 1 - 38
  • [5] Gamma electron vertex imaging and application to beam range verification in proton therapy
    Kim, Chan Hyeong
    Park, Jin Hyung
    Seo, Hee
    Lee, Han Rim
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1001 - 1005
  • [6] Pinhole Camera Measurements of Prompt Gamma-rays for Detection of Beam Range Variation in Proton Therapy
    Kim, Dogyun
    Yim, Heejung
    Kim, Jong-Won
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1673 - 1676
  • [7] In vivo proton range verification: a review
    Knopf, Antje-Christin
    Lomax, Antony
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) : 131 - 160
  • [8] Nuclear deexcitation gamma-ray lines from accelerated particle interactions
    Kozlovsky, B
    Murphy, RJ
    Ramaty, R
    [J]. ASTROPHYSICAL JOURNAL SUPPLEMENT SERIES, 2002, 141 (02) : 523 - 541
  • [9] Development of a Compton camera for medical applications based on silicon strip and scintillation detectors
    Krimmer, J.
    Ley, J. -L.
    Abellan, C.
    Cachemiche, J. -P.
    Caponetto, L.
    Chen, X.
    Dahoumane, M.
    Dauvergne, D.
    Freud, N.
    Joly, B.
    Lambert, D.
    Lestand, L.
    Letang, J. M.
    Magne, M.
    Mathez, H.
    Maxim, V.
    Montarou, G.
    Morel, C.
    Pinto, M.
    Ray, C.
    Reithinger, V.
    Testa, E.
    Zoccarato, Y.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 98 - 101
  • [10] Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations
    Krimmer, J.
    Chevallier, M.
    Constanzo, J.
    Dauvergne, D.
    De Rydt, M.
    Dedes, G.
    Freud, N.
    Henriquet, P.
    La Tessa, C.
    Letang, J. M.
    Pleskac, R.
    Pinto, M.
    Ray, C.
    Reithinger, V.
    Richard, M. H.
    Rinaldi, I.
    Roellinghoff, F.
    Schuy, C.
    Testa, E.
    Testa, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10