Comparison of automated and retrospectively calculated estimated glomerular filtration rate in electronic health record data

被引:1
|
作者
Lynch, Kristine E. [1 ,2 ]
Chang, Ji Won [1 ,2 ]
Matheny, Michael E. [3 ,4 ]
Goldfarb, Alexander [5 ,6 ]
Efimova, Olga [1 ,2 ]
Coronado, Gregorio [1 ,2 ]
DuVall, Scott L. [1 ,2 ]
机构
[1] VA Salt Lake City Hlth Care Syst, VA Informat & Comp Infrastruct VINCI, Salt Lake City, UT 84148 USA
[2] Univ Utah, Dept Internal Med, Div Epidemiol, Salt Lake City, UT 84112 USA
[3] Tennessee Valley Healthcare Syst, Geriatr Res Educ & Clin Care Ctr, Nashville, TN USA
[4] Vanderbilt Univ, Med Ctr, Dept Biomed Informat, Nashville, TN USA
[5] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[6] Harvard Med Sch, Boston, MA USA
关键词
CHRONIC KIDNEY-DISEASE; POSITION STATEMENT; SERUM CREATININE; ELDERLY ADULTS; RENAL-DISEASE; ESTIMATED GFR; VETERANS; OUTCOMES; CARE; CLASSIFICATION;
D O I
10.1186/s12882-018-1179-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
BackgroundEstimated glomerular filtration rate (eGFR) is the clinical standard for assessing kidney function and staging chronic kidney disease. Automated reporting of eGFR using the Modification of Diet in Renal Disease (MDRD) study equation was first implemented within the Department of Veterans Affairs (VA) in 2007 with staggered adoption across laboratories. When automated eGFR are not used or unavailable, values are retrospectively calculated using clinical and demographic data that are currently available in the electronic health record (EHR). Due to the dynamic nature of EHRs, current data may not always match past data. Whether and to what extent the practice of re-calculating eGFR on retrospective data differs from using the automated values is unknown.MethodsWe assessed clinical data for patients enrolled in VA who had their first automated eGFR lab in 2013.We extracted the eGFR value, the corresponding serum creatinine value, and patient race, gender, and date of birth from the EHR. The MDRD equation was applied to retrospectively calculate eGFR. Stage of chronic kidney disease (CKD) was defined using both eGFR values. We used Bland-Altman plots and percent agreement to assess the difference between the automated and calculated values. We developed an algorithm to select the most parsimonious parameter set to explain the difference in values and used chart review on a small subsample of patients to determine if one approach more accurately describes the patient at the time of eGFR measurement.ResultsWe evaluated eGFR data pairs from 266,084 patients. Approximately 33.0% (n=86,747) of eGFR values differed between automated and retrospectively calculated methods. The majority of discordant pairs were classified as the same CKD stage (n=74,542, 85.93%). The Bland-Altman plot showed differences in the data pairs were centered near zero (mean difference: 0.8mL/min/1.73m(2)) with 95% limits of agreement between -6.4 and 8.0. A change in recorded age explained 95.6% (n=78,903) of discordant values and 85.02% (n=9371) of the discordant stages.ConclusionsValues of retrospectively calculated eGFR can differ from automated values, but do not always result in a significant classification change. In very large datasets these small differences could become significant.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Impact of Automated Reporting of Estimated Glomerular Filtration Rate in the Veterans Health Administration
    Wang, Virginia
    Hammill, Bradley G.
    Maciejewski, Matthew L.
    Hall, Rasheeda K.
    Van Scoyoc, Lynn
    Garg, Amit X.
    Jain, Arsh K.
    Patel, Uptal D.
    MEDICAL CARE, 2015, 53 (02) : 177 - 183
  • [2] Automated laboratory reporting of estimated glomerular filtration rate: is it good for the health of patients and their doctors?
    Noble, Euan
    Johnson, David W.
    BIOCHEMIA MEDICA, 2007, 17 (01) : 16 - 28
  • [3] Impact of estimated glomerular filtration rate reporting on nephrology referrals: a review of the literature
    Jain, Arsh
    Hemmelgarn, Brenda R.
    CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2011, 20 (03) : 218 - 223
  • [4] A regional survey of serum creatinine measurement methods and estimated glomerular filtration rate reporting
    Imbasciati, Enrico
    Falbo, Rosanna
    Mariani, Paola
    Signorelli, Silvia
    Stella, Andrea
    Brambilla, Paolo
    JOURNAL OF NEPHROLOGY, 2013, 26 (02) : 396 - 402
  • [5] Estimated glomerular filtration rate: time for a performance review?
    Glassock, Richard J.
    KIDNEY INTERNATIONAL, 2009, 75 (10) : 1001 - 1003
  • [6] Estimated glomerular filtration rate in people living with HIV
    Pontes, Priscila Silva
    Melo, Elizabete Santos
    Braz Costa, Christefany Regia
    Antonini, Marcela
    Milanes Sousa, Laelson Rochelle
    Gir, Elucir
    Reis, Renata Karina
    ACTA PAULISTA DE ENFERMAGEM, 2019, 32 (05) : 493 - 499
  • [7] Nephrology Visits and Health Care Resource Use Before and After Reporting Estimated Glomerular Filtration Rate
    Hemmelgarn, Brenda R.
    Zhang, Jianguo
    Manns, Braden J.
    James, Matthew T.
    Quinn, Robert R.
    Ravani, Pietro
    Klarenbach, Scott W.
    Culleton, Bruce F.
    Krause, Richard
    Thorlacius, Laurel
    Jain, Arsh K.
    Tonelli, Marcello
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 303 (12): : 1151 - 1158
  • [8] Should Estimated Glomerular Filtration Rate Be Adjusted for Race?
    Cohen, Brian J.
    CLINICAL PHARMACOLOGY IN DRUG DEVELOPMENT, 2021, 10 (11): : 1254 - 1262
  • [9] Implementation of automated reporting of estimated glomerular filtration rate among Veterans Affairs laboratories: a retrospective study
    Hall, Rasheeda K.
    Wang, Virginia
    Jackson, George L.
    Hammill, Bradley G.
    Maciejewski, Matthew L.
    Yano, Elizabeth M.
    Svetkey, Laura P.
    Patel, Uptal D.
    BMC MEDICAL INFORMATICS AND DECISION MAKING, 2012, 12
  • [10] RATIONAL TESTING Estimated glomerular filtration rate
    O'Riordan, Philly
    Stevens, Paul E.
    Lamb, Edmund J.