Release of carbon nanotubes during combustion of polymer nanocomposites in a pilot-scale facility for waste incineration

被引:6
|
作者
Janhall, Sara
Petersson, Mikaela [2 ]
Davidsson, Kent [1 ]
Oman, Tommy [1 ]
Sommertune, Jens [1 ]
Karedal, Monica [3 ,4 ]
Messing, Maria E. [2 ,4 ]
Rissler, Jenny [1 ,4 ,5 ]
机构
[1] RISE Res Inst Sweden, Box 857, SE-50115 Boras, Sweden
[2] Lund Univ, Fac Sci, Dept Phys, Solid State Phys, Box 188, SE-22100 Lund, Sweden
[3] Lund Univ, Fac Med, Dept Lab Med, Occupat & Environm Med, Box 188, SE-22100 Lund, Sweden
[4] Lund Univ, NanoLund, Box 188, SE-22100 Lund, Sweden
[5] Lund Univ, Fac Engn, Ergon & Aerosol Technol, Box 118, SE-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
Waste incineration; Polymer; CNT; Particle; Fly ash; Nanocomposites; ENGINEERED NANOMATERIALS; ENVIRONMENTAL-HEALTH; FATE; NANOPARTICLES; BIOMARKERS; EMISSIONS; EXPOSURE; RISKS;
D O I
10.1016/j.impact.2021.100357
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nanocomposites, formed by incorporating nanoparticles into a matrix of standard materials, are increasing on the market. Little focus has been directed towards safe disposal and recycling of these new materials even though the disposal has been identified as a phase of the products' life cycle with a high risk of uncontrolled emissions of nanomaterials. In this study, we investigate if the carbon nanotubes (CNTs), when used as a filler in two types of polymers, are fully destructed in a pilot-scale combustion unit designed to mimic the combustion under waste incineration. The two polymer nanocomposites studied, polycarbonate (PC) with CNT and high-density polyethylene (HDPE) with CNT, were incinerated at two temperatures where the lower temperature just about fulfilled the European waste incineration directive while the upper was chosen to be on the safe side of fulfilling the directive. Particles in the flue gas were sampled and analysed with online and offline instrumentation along with samples of the bottom ash. CNTs could be identified in the flue gas in all experiments, although present to a greater extent when the CNTs were introduced in PC as compared to in HDPE. In the case of using PC as polymer matrix, CNTs were identified in 3-10% of the analysed SEM images while for HDPE in only similar to 0.5% of the images. In the case of PC, the presence of CNTs decreased with increasing bed temperature (from 10% to 3% of the images). The CNTs identified were always in bundles, often coated with remnants of the polymer, forming particles of similar to 1-4 mu m in diameter. No CNTs were identified in the bottom ash, likely explained by the difference in time when the bottom ash and fly ash are exposed to high temperatures (similar to hours compared to seconds) in the pilot facility. The results suggest that the residence time of the fly ash in the combustion zone is not long enough to allow full oxidation of the CNTs. Thus, the current regulation on waste incineration (requiring a residence time of the flue gas >850 degrees C during at least 2 s) may not be enough to obtain complete destruction of CNTs in polymer composites. Since several types of CNTs are known to be toxic, we stress the need for further investigation of the fate and toxicity of CNTs in waste treatment processes.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Experimental characterization of pulverized coal MILD flameless combustion from detailed measurements in a pilot-scale facility
    Weidmann, Max
    Honore, David
    Verbaere, Vincent
    Boutin, Guillaume
    Grathwohl, Simon
    Godard, Gilles
    Gobin, Carole
    Kneer, Reinhold
    Scheffknecht, Guenter
    COMBUSTION AND FLAME, 2016, 168 : 365 - 377
  • [22] Investigation of slagging in pulverized fuel co-combustion of biomass and coal at a pilot-scale test facility
    Heinzel, T
    Siegle, V
    Spliethoff, H
    Hein, KRG
    FUEL PROCESSING TECHNOLOGY, 1998, 54 (1-3) : 109 - 125
  • [23] Pyrolysis and combustion characteristics of waste wood Biomass in a pilot-scale pyrolysis-melting incinerator
    Park, Ju Won
    Kim, Bong Keun
    Lee, Gi Bang
    Park, Sang Shin
    Yang, Won
    Yu, Tae U.
    Jeon, Keum Ha
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 1089 - +
  • [24] SORPTION TREATMENT OF WASTE WATER TO REMOVE PHENOLS IN A PILOT-SCALE FACILITY USING A PRESSURE COLUMN.
    Murabuldaev, M.Ch.
    Kulik, A.I.
    Kulinich, M.S.
    Belova, O.I.
    D'yakov, V.S.
    Ryabchikov, B.E.
    Zakharov, E.I.
    Coke and chemistry U.S.S.R., 1987, (07): : 85 - 88
  • [25] Activated carbon enhanced anaerobic digestion of food waste - Laboratory-scale and Pilot-scale operation
    Zhang, Le
    Zhang, Jingxin
    Loh, Kai-Chee
    WASTE MANAGEMENT, 2018, 75 : 270 - 279
  • [26] The production cost analysis of oil palm waste activated carbon: a pilot-scale evaluation
    Lai, Jia Yen
    Ngu, Lock Hei
    GREENHOUSE GASES-SCIENCE AND TECHNOLOGY, 2020, 10 (05) : 999 - 1026
  • [27] Measurement and modeling of heavy metal behaviors during the incineration of RDF in a pilot-scale kiln incinerator-Part 2: Incineration test
    Yui, Kazuko
    Kuramochi, Hidetoshi
    Osako, Masahiro
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 159 : 899 - 910
  • [28] Large-eddy simulation of coal combustion in 15 MW pilot-scale boiler-simulation facility
    Zhou, Minmin
    Parra-Alvarez, John
    Wu, Yuxin
    Smith, Sean T.
    Smith, Philip J.
    AICHE JOURNAL, 2021, 67 (08)
  • [29] LES and RANS of air and oxy-coal combustion in a pilot-scale facility: Predictions of radiative heat transfer
    Clements, Alastair G.
    Black, Sandy
    Szuhanszki, Janos
    Stechly, Katarzyna
    Pranzitelli, Alessandro
    Nimmo, William
    Pourkashanian, Mohamed
    FUEL, 2015, 151 : 146 - 155
  • [30] Continuous, pilot-scale production of carbon fiber from a textile grade PAN polymer
    Khan, Huma
    Kaur, Jasjeet
    Naebe, Minoo
    Hutchinson, Sally
    Varley, Russell J.
    Materials Today Communications, 2022, 31