Radiation Exposure to the Sacroiliac Joint From Low-Dose CT Compared With Radiography

被引:23
|
作者
Chahal, Baljot S. [1 ]
Kwan, Alexander L. C. [1 ]
Dhillon, Sukhvinder S. [1 ]
Olubaniyi, Babajide O. [2 ]
Jhiangri, Gian S. [3 ]
Neilson, Matthew M. [1 ]
Lambert, Robert G. W. [1 ]
机构
[1] Univ Alberta, Fac Med & Dent, Dept Radiol & Diagnost Imaging, 2A2-41 WC MacKenzie Hlth Sci Ctr,8440-112 St, Edmonton, AB T6G 2B7, Canada
[2] Univ Calgary, Cumming Sch Med, Dept Radiol, Calgary, AB, Canada
[3] Univ Alberta, Sch Publ Hlth, Edmonton, AB, Canada
关键词
low-dose CT; radiation; radiography; sacroiliac joint; spondyloarthropathy; COMPUTED-TOMOGRAPHY; ANKYLOSING-SPONDYLITIS;
D O I
10.2214/AJR.18.19678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The primary objective of this study was to estimate the effective dose delivered to the sacroiliac joint (SIJ) from low-dose (LD) CT compared with that from radiography. Secondary objectives included evaluation of diagnostic quality of LD CT of the SIJ and development of a clinical protocol for LD CT of the SIJ. MATERIALS AND METHODS. Data from 36 patients (19 women, 17 men) undergoing LD CT for suspected renal colic were analyzed. Two effective dose estimates were calculated: one for the SIJ and another for an extended region from the iliac crest to 1 cm below the SIJ. Thirty-six anteroposterior pelvic and 36 SIJ view radiographs were age-, sex-, and body width-matched to CT scans. Effective dose from radiography was estimated using the method described in International Commission on Radiologic Protection Publication 60. RESULTS. Maximum effective dose to the SIJ from LD CT was less than 1 mSv in all cases, with a mean +/- SD of 0.42 +/- 0.18 mSv (range, 0.14-0.83 mSv), whereas mean dose to the extended region was 0.57 +/- 0.24 mSv (range, 0.19-1.11 mSv). Mean dose from SIJ radiographs was 0.15 +/- 0.10 mSv (range, 0.07-1.38 mSv), and mean dose from a single pelvic radiograph was 0.09 +/- 0.06 mSv (range, 0.04-0.37 mSv). All CT studies were of diagnostic quality for assessment of the SIJ. CONCLUSION. LD CT of the SIJ can be consistently performed with an effective radiation dose of less than 1 mSv. Because reliability and sensitivity of radiography for sacroiliitis is poor, we recommend that LD CT replace radiography for dedicated evaluation of the SIJ.
引用
收藏
页码:1058 / 1062
页数:5
相关论文
共 50 条
  • [41] LOW-DOSE CT DENOISING WITH CONVOLUTIONAL NEUELA NETWORK
    Chen, Hu
    Zhang, Yi
    Zhang, Weihua
    Liao, Peixi
    Li, Ke
    Zhou, Jiliu
    Wang, Ge
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 143 - 146
  • [42] Preoperative CT-guided localization of pulmonary nodules with low-dose radiation
    Ma, Yanhe
    Cheng, Shizhao
    Li, Jianhui
    Yuan, Wei
    Song, Zhenchun
    Zhang, Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (07) : 4295 - 4304
  • [43] Deep learning for low-dose CT
    Chen, Hu
    Zhang, Yi
    Zhou, Jiliu
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [44] Low-dose Quantitative Cone-beam CT Imaging in Radiation Therapy
    Niu, Tianye
    Zhu, Lei
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2907 - 2909
  • [45] Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms
    Othman, A. E.
    Afat, S.
    Brockmann, C.
    Nikoubashman, O.
    Bier, G.
    Brockmann, M. A.
    Nikolaou, K.
    Tai, J. H.
    Yang, Z. P.
    Kim, J. H.
    Wiesmann, M.
    CLINICAL NEURORADIOLOGY, 2017, 27 (03) : 311 - 318
  • [46] On the problem of low-dose effects: Oncogenic consequences of low-dose irradiation with ionizing radiation
    V. I. Korogodin
    V. L. Korogodina
    Atomic Energy, 1997, 82 : 33 - 37
  • [47] On the problem of low-dose effects: Oncogenic consequences of low-dose irradiation with ionizing radiation
    Korogodin, VI
    Korogodina, VL
    ATOMIC ENERGY, 1997, 82 (01) : 33 - 37
  • [48] Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison
    Tobias Pflederer
    Josy Jakstat
    Mohamed Marwan
    Tiziano Schepis
    Sven Bachmann
    Axel Kuettner
    Katharina Anders
    Michael Lell
    Gerd Muschiol
    Dieter Ropers
    Werner G. Daniel
    Stephan Achenbach
    European Radiology, 2010, 20 : 1197 - 1206
  • [49] Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison
    Pflederer, Tobias
    Jakstat, Josy
    Marwan, Mohamed
    Schepis, Tiziano
    Bachmann, Sven
    Kuettner, Axel
    Anders, Katharina
    Lell, Michael
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner G.
    Achenbach, Stephan
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1197 - 1206
  • [50] Low-Dose Coronary CT Angiography in Patients with Atrial Fibrillation: Comparison of Image Quality and Radiation Exposure with Two Different Approaches
    Mushtaq, Saima
    Pontone, Gianluca
    Conte, Edoardo
    Guglielmo, Marco
    Consiglio, Elisa
    Magatelli, Marco
    Oliveira, Margarida
    Muscogiuri, Giuseppe
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Mancini, Maria Elisabetta
    Di Odoardo, Luca
    Melotti, Eleonora
    Fiorentini, Cesare
    Bartorelli, Antonio L.
    Pepi, Mauro
    Andreini, Daniele
    ACADEMIC RADIOLOGY, 2019, 26 (06) : 791 - 797