Radiation Exposure to the Sacroiliac Joint From Low-Dose CT Compared With Radiography

被引:23
|
作者
Chahal, Baljot S. [1 ]
Kwan, Alexander L. C. [1 ]
Dhillon, Sukhvinder S. [1 ]
Olubaniyi, Babajide O. [2 ]
Jhiangri, Gian S. [3 ]
Neilson, Matthew M. [1 ]
Lambert, Robert G. W. [1 ]
机构
[1] Univ Alberta, Fac Med & Dent, Dept Radiol & Diagnost Imaging, 2A2-41 WC MacKenzie Hlth Sci Ctr,8440-112 St, Edmonton, AB T6G 2B7, Canada
[2] Univ Calgary, Cumming Sch Med, Dept Radiol, Calgary, AB, Canada
[3] Univ Alberta, Sch Publ Hlth, Edmonton, AB, Canada
关键词
low-dose CT; radiation; radiography; sacroiliac joint; spondyloarthropathy; COMPUTED-TOMOGRAPHY; ANKYLOSING-SPONDYLITIS;
D O I
10.2214/AJR.18.19678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The primary objective of this study was to estimate the effective dose delivered to the sacroiliac joint (SIJ) from low-dose (LD) CT compared with that from radiography. Secondary objectives included evaluation of diagnostic quality of LD CT of the SIJ and development of a clinical protocol for LD CT of the SIJ. MATERIALS AND METHODS. Data from 36 patients (19 women, 17 men) undergoing LD CT for suspected renal colic were analyzed. Two effective dose estimates were calculated: one for the SIJ and another for an extended region from the iliac crest to 1 cm below the SIJ. Thirty-six anteroposterior pelvic and 36 SIJ view radiographs were age-, sex-, and body width-matched to CT scans. Effective dose from radiography was estimated using the method described in International Commission on Radiologic Protection Publication 60. RESULTS. Maximum effective dose to the SIJ from LD CT was less than 1 mSv in all cases, with a mean +/- SD of 0.42 +/- 0.18 mSv (range, 0.14-0.83 mSv), whereas mean dose to the extended region was 0.57 +/- 0.24 mSv (range, 0.19-1.11 mSv). Mean dose from SIJ radiographs was 0.15 +/- 0.10 mSv (range, 0.07-1.38 mSv), and mean dose from a single pelvic radiograph was 0.09 +/- 0.06 mSv (range, 0.04-0.37 mSv). All CT studies were of diagnostic quality for assessment of the SIJ. CONCLUSION. LD CT of the SIJ can be consistently performed with an effective radiation dose of less than 1 mSv. Because reliability and sensitivity of radiography for sacroiliitis is poor, we recommend that LD CT replace radiography for dedicated evaluation of the SIJ.
引用
收藏
页码:1058 / 1062
页数:5
相关论文
共 50 条
  • [31] A unit of measurement adapted to the evaluation of the effects of low-dose radiation exposure
    Charpak, G
    Garwin, R
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2001, 185 (06): : 1087 - 1096
  • [32] Low-Dose CT for Craniosynostosis: Preserving Diagnostic Benefit with Substantial Radiation Dose Reduction
    Montoya, J. C.
    Eckel, L. J.
    DeLone, D. R.
    Kotsenas, A. L.
    Diehn, F. E.
    Yu, L.
    Bartley, A. C.
    Carter, R. E.
    McCollough, C. H.
    Fletcher, J. G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (04) : 672 - 677
  • [33] In Vivo Comparison of Radiation Exposure of Dual-Energy CT Versus Low-Dose CT Versus Standard CT for Imaging Urinary Calculi
    Jepperson, Maria A.
    Cernigliaro, Joseph G.
    Ibrahim, El-Sayed H.
    Morin, Richard L.
    Haley, William E.
    Thiel, David D.
    JOURNAL OF ENDOUROLOGY, 2015, 29 (02) : 141 - 146
  • [34] Low-dose CT scan screening for lung cancer: comparison of images and radiation doses between low-dose CT and follow-up standard diagnostic CT
    Ono, Koji
    Hiraoka, Toru
    Ono, Asami
    Komatsu, Eiji
    Shigenaga, Takehiko
    Takaki, Hajime
    Maeda, Toru
    Ogusu, Hiroyuki
    Yoshida, Shintaro
    Fukushima, Kiyoyasu
    Kai, Michiaki
    SPRINGERPLUS, 2013, 2 : 1 - 8
  • [35] Low-dose CT examination for rib fracture evaluation: A pilot study
    Jin, Liang
    Ge, Xiaojun
    Lu, Fang
    Sun, Yingli
    Li, Cheng
    Gao, Pan
    Gao, Feng
    Li, Ming
    MEDICINE, 2018, 97 (30)
  • [36] Study of peripheral dose from low-dose CT to adaptive radiotherapy of postoperative prostate cancer
    Gan, Guanghui
    Gong, Wei
    Jia, Lecheng
    Zhang, Wei
    Wang, Shimei
    Zhou, Juying
    Jiang, Hua
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [37] Use of BMI Guidelines and Individual Dose Tracking to Minimize Radiation Exposure from Low-dose Helical Chest CT Scanning in a Lung Cancer Screening Program
    Manowitz, Amy
    Sedlar, Marija
    Griffon, Mark
    Miller, Albert
    Miller, Jeffrey
    Markowitz, Steven
    ACADEMIC RADIOLOGY, 2012, 19 (01) : 84 - 88
  • [38] A Joint-Parameter Estimation and Bayesian Reconstruction Approach to Low-Dose CT
    Gao, Yongfeng
    Lu, Siming
    Shi, Yongyi
    Chang, Shaojie
    Zhang, Hao
    Hou, Wei
    Li, Lihong
    Liang, Zhengrong
    SENSORS, 2023, 23 (03)
  • [39] Image quality of EOS low-dose radiography in comparison with conventional radiography for assessment of ventriculoperitoneal shunt integrity
    Monuszko, Karen
    Malinzak, Michael
    Yang, Lexie Zidanyue
    Niedzwiecki, Donna
    Fuchs, Herbert
    Muh, Carrie R.
    Gingrich, Krista
    Lark, Robert
    Thompson, Eric M.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2021, 27 (04) : 375 - 381
  • [40] Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?
    Takahashi, Hiroto
    Okada, Masahiro
    Hyodo, Tomoko
    Hidaka, Syojiro
    Kagawa, Yuki
    Matsuki, Mitsuru
    Tsurusaki, Masakatsu
    Murakami, Takamichi
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (04) : 684 - 691