Radiation Exposure to the Sacroiliac Joint From Low-Dose CT Compared With Radiography

被引:23
|
作者
Chahal, Baljot S. [1 ]
Kwan, Alexander L. C. [1 ]
Dhillon, Sukhvinder S. [1 ]
Olubaniyi, Babajide O. [2 ]
Jhiangri, Gian S. [3 ]
Neilson, Matthew M. [1 ]
Lambert, Robert G. W. [1 ]
机构
[1] Univ Alberta, Fac Med & Dent, Dept Radiol & Diagnost Imaging, 2A2-41 WC MacKenzie Hlth Sci Ctr,8440-112 St, Edmonton, AB T6G 2B7, Canada
[2] Univ Calgary, Cumming Sch Med, Dept Radiol, Calgary, AB, Canada
[3] Univ Alberta, Sch Publ Hlth, Edmonton, AB, Canada
关键词
low-dose CT; radiation; radiography; sacroiliac joint; spondyloarthropathy; COMPUTED-TOMOGRAPHY; ANKYLOSING-SPONDYLITIS;
D O I
10.2214/AJR.18.19678
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The primary objective of this study was to estimate the effective dose delivered to the sacroiliac joint (SIJ) from low-dose (LD) CT compared with that from radiography. Secondary objectives included evaluation of diagnostic quality of LD CT of the SIJ and development of a clinical protocol for LD CT of the SIJ. MATERIALS AND METHODS. Data from 36 patients (19 women, 17 men) undergoing LD CT for suspected renal colic were analyzed. Two effective dose estimates were calculated: one for the SIJ and another for an extended region from the iliac crest to 1 cm below the SIJ. Thirty-six anteroposterior pelvic and 36 SIJ view radiographs were age-, sex-, and body width-matched to CT scans. Effective dose from radiography was estimated using the method described in International Commission on Radiologic Protection Publication 60. RESULTS. Maximum effective dose to the SIJ from LD CT was less than 1 mSv in all cases, with a mean +/- SD of 0.42 +/- 0.18 mSv (range, 0.14-0.83 mSv), whereas mean dose to the extended region was 0.57 +/- 0.24 mSv (range, 0.19-1.11 mSv). Mean dose from SIJ radiographs was 0.15 +/- 0.10 mSv (range, 0.07-1.38 mSv), and mean dose from a single pelvic radiograph was 0.09 +/- 0.06 mSv (range, 0.04-0.37 mSv). All CT studies were of diagnostic quality for assessment of the SIJ. CONCLUSION. LD CT of the SIJ can be consistently performed with an effective radiation dose of less than 1 mSv. Because reliability and sensitivity of radiography for sacroiliitis is poor, we recommend that LD CT replace radiography for dedicated evaluation of the SIJ.
引用
收藏
页码:1058 / 1062
页数:5
相关论文
共 50 条
  • [1] Radiography and abdominal CT compared with sacroiliac joint CT in the diagnosis of sacroiliitis
    Melchior, Julian
    Azraq, Yusef
    Chary-Valckenaere, Isabelle
    Rat, Anne-Christine
    Texeira, Pedro
    Blum, Alain
    Loeuille, Damien
    ACTA RADIOLOGICA, 2017, 58 (10) : 1252 - 1259
  • [2] Effective dose in low-dose CT compared with radiography for templating of total hip arthroplasty
    Geijer, Mats
    Rundgren, Gustav
    Weber, Lars
    Flivik, Gunnar
    ACTA RADIOLOGICA, 2017, 58 (10) : 1276 - 1282
  • [3] Radiography, abdominal CT and MRI compared with sacroiliac joint CT in diagnosis of structural sacroiliitis
    Melchior, Julian
    Azraq, Yusef
    Chary-Valckenaere, Isabelle
    Rat, Anne-Christine
    Reignac, Marion
    Texeira, Pedro
    Blum, Alain
    Loeuille, Damien
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 95 : 169 - 176
  • [4] Not Every Low-Dose Is Low-Dose: Impact of Revising Low-Dose CT Protocol on Mean Effective Radiation Exposure
    Deyirmendjian, Claudia
    Lee, Seohyuk
    Noureldin, Yasser A.
    Hegyi, Gyorgy
    Stein, Lawrence
    Artho, Giovanni
    Andonian, Sero
    JOURNAL OF ENDOUROLOGY, 2022, 36 (06) : 835 - 840
  • [5] Effective radiation dose from semicoronal CT of the sacroiliac joints in comparison with axial CT and conventional radiography
    Jurik, AG
    Hansen, J
    Puhakka, KB
    EUROPEAN RADIOLOGY, 2002, 12 (11) : 2820 - 2825
  • [6] Low-dose CT of postoperative pelvic fractures: a comparison with radiography
    Eriksson, Thomas
    Berg, Per
    Olerud, Claes
    Shalabi, Adel
    Hanni, Mari
    ACTA RADIOLOGICA, 2019, 60 (01) : 85 - 91
  • [7] BIOLOGICAL EFFECTS OF LOW-DOSE RADIATION FROM CT IMAGING
    Lierova, Anna
    Milanova, Marcela
    Pospichal, Jan
    Novotny, Jan
    Storm, Jaroslav
    Andrejsova, Lenka
    Sinkorova, Zuzana
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (9-11) : 514 - 520
  • [8] HEALTH BENEFITS OF EXPOSURE TO LOW-DOSE RADIATION
    Rithidech, Kanokporn Noy
    HEALTH PHYSICS, 2016, 110 (03): : 293 - 295
  • [9] The health effects of low-dose radiation exposure
    Do, Kyung-Hyun
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2011, 54 (12): : 1253 - 1261
  • [10] MRI compared with low-dose CT scanning in the diagnosis of axial spondyloarthritis
    Ye, Lusi
    Liu, Yuncai
    Xiao, Qinqin
    Dong, Ledan
    Wen, Caiyun
    Zhang, Zhang
    Jin, Mengmeng
    Brown, Matthew A.
    Chen, Dan