A liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of escin Ia and escin Ib in human plasma: application to a pharmacokinetic study after intravenous administration

被引:9
|
作者
Liu, Lidong [1 ]
Wu, Xiujun [1 ,2 ]
Wu, Dan [1 ]
Wang, Yingwu [1 ]
Li, Pengfei [1 ]
Sun, Yantong [1 ]
Yang, Yan [1 ]
Gu, Jingkai [1 ]
Cui, Yimin [3 ]
机构
[1] Jilin Univ, Res Ctr Drug Metab, Coll Life Sci, Changchun 130021, Peoples R China
[2] Liaoning Univ Tradit Chinese Med, Affiliated Hosp, Shenyang 110041, Peoples R China
[3] Peking Univ, Dept Pharm, Hosp 1, Beijing 100871, Peoples R China
关键词
escin Ia; escin Ib; LC-MS/MS; pharmacokinetics; AESCULUS-HIPPOCASTANUM L; HORSE-CHESTNUT; TRITERPENE OLIGOGLYCOSIDES; HYPOGLYCEMIC ACTIVITY; ETHANOL ABSORPTION; BIOACTIVE SAPONINS; SEEDS; EXTRACT; IIB; FORMULATIONS;
D O I
10.1002/bmc.1441
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous quantification of escin Ia and escin Ib in human plasma. After a solid-phase extraction (SPE), the analytes were separated on a Zorbax Extend C-18 column by isocratic elution with a mobile phase of methanol-acetonitrile-10 mM ammonium acetate (27:27:46, v/v/v) at a flow rate of 1.0 mL/min and analyzed by mass spectrometry in the positive ion multiple reaction monitoring mode. The precursor to product ion transitions of m/z 1131.8 -> 807.6 was used to quantify escin Ia and escin Ib. Good linearity was achieved over a wide range of 2.00-900 ng/mL for escin Ia and 1.50-662 ng/mL for escin Ib. The intra-and inter-day precisions (as relative standard deviation) were less than 11% for each QC level of escin Ia and escin Ib. The accuracies (as relative error) were within +/- 5.27% for escin Ia and within +/- 4.07% for escin Ib. The method was successfully employed in a pharmacokinetic study after a single intravenous infusion administration of sodium aescinate injection containing 10 mg escin to each of the 10 healthy volunteers. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1309 / 1315
页数:7
相关论文
共 50 条
  • [21] Simultaneous quantification of amiloride and hydrochlorothiazide in human plasma by liquid chromatography-tandem mass spectrometry
    Shah, Jaivik V.
    Shah, Priyanka A.
    Sanyal, Mallika
    Shrivastav, Pranav S.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (05) : 288 - 296
  • [22] Simultaneous determination of glimepiride and pioglitazone in human plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study
    Ni, Xiao-Jia
    Wang, Zhan-Zhang
    Shang, De-Wei
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Wen, Yu-Guan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 247 - 252
  • [23] Rapid and efficient method for the quantification of lychnopholide in rat plasma by liquid chromatography-tandem mass spectrometry for pharmacokinetic application
    Lachi-Silva, Larissa
    Barreto Sousa, Joao Paulo
    Montanha, Maiara Camotti
    Sy, Sherwin K. B.
    Callegari Lopes, Joao Luis
    Silva, Denise Brentan
    Lopes, Norberto Peporine
    Diniz, Andrea
    Kimura, Elza
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (07) : 1092 - 1096
  • [24] Validated liquid chromatography-tandem mass spectrometry method for quantitative determination of dauricine in human plasma and its application to pharmacokinetic study
    Liu, Xiaoying
    Liu, Qian
    Wang, Dongmei
    Wang, Xueya
    Zhang, Peng
    Xu, Haiyan
    Zhao, Hui
    Zhao, Huaiqing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1199 - 1203
  • [25] Determination of chamaechromone in rat plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study
    Lou, Yan
    Hu, Haihong
    Liu, Yao
    Yu, Qinqin
    Li, Li
    Ping, Li
    Yu, Lushan
    Jiang, Huidi
    Zeng, Su
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1163 - 1169
  • [26] Determination of Tenacissoside A in rat plasma by liquid chromatography-tandem mass spectrometry method and its application to pharmacokinetic study
    Zhao, Luhua
    Xiang, Bingren
    Chen, Jing
    Tan, Xiying
    Wang, Dawei
    Chen, Daofeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (20-21): : 1799 - 1804
  • [27] Liquid chromatography-tandem mass spectrometry bioanalytical method for the determination of kavain in mice plasma: Application to a pharmacokinetic study
    Ferreira, Juliana Veloso
    Braga, Alysson Vinicius
    Machado, Renes de Resende
    Michel, Deborah
    Pianetti, Gerson Antonio
    El-Aneed, Anas
    Cesar, Isabela Costa
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1137 (1137):
  • [28] Liquid chromatography/negative ion electrospray tandem mass spectrometry method for the quantification of rosuvastatin in human plasma: Application to a pharmacokinetic study
    Gao, Jun
    Zhong, Dafang
    Duan, Xiaotao
    Chen, Xiaoyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 35 - 40
  • [29] Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of tamoxifen, anastrozole, and letrozole in human plasma and its application to a clinical study
    Beer, Beate
    Schubert, Birthe
    Oberguggenberger, Anne
    Meraner, Verena
    Hubalek, Michael
    Oberacher, Herbert
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (04) : 1791 - 1800
  • [30] Rapid quantification of astilbin in rat plasma by liquid chromatography-tandem mass spectrometry and its application to pharmacokinetic study
    Yin Lei
    Zhang Yun-hui
    Zhao Sen
    Cheng Long-mei
    Shi Mei-yun
    Yang Yan
    Sun Yan-tong
    Liu Xi-dong
    Fawcett, J. Paul
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (06) : 1078 - 1082