Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: Meta-analysis

被引:319
作者
Vanhoenacker, Piet K.
Heijenbrok-Kal, Majanka H.
Van Heste, Ruben
Decramer, Isabel
Van Hoe, Lieven R.
William, Wijns
Hunink, M. G. Myriam
机构
[1] OLV Ziekenhuis Aalst, Dept Radiol & Med Imaging, B-9300 Aalst, Belgium
[2] OLV Ziekenhuis Aalst, Ctr Cardiovasc, B-9300 Aalst, Belgium
[3] Erasmus MC Univ Med Ctr Rotterdam, Dept Epidemiol & Biostat, Program Assessment Radiol Technol, Rotterdam, Netherlands
[4] Erasmus MC Univ Med Ctr Rotterdam, Dept Radiol, Rotterdam, Netherlands
关键词
D O I
10.1148/radiol.2442061218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To review the literature on the diagnostic performance of multidetector computed tomographic (CT) angiography for assessment of symptomatic coronary artery disease, with conventional coronary angiography as the reference standard. Materials and Methods: A PubMed and manual search of the literature published between January 1998 and May 2006 on use of multidetector CT angiography compared with coronary angiography in patients with symptomatic coronary artery disease was performed. Summary estimates of diagnostic odds ratio, sensitivity, and specificity were calculated. Random-effects models were used to compare the diagnostic performance of four-, 16-, and 64-detector CT angiographic units, and the proportion of nonassessable coronary arterial segments was evaluated. Results: Fifty-four studies were included in the meta-analysis: 22 studies with four-detector CT angiography, 26 with 16-detector CT angiography, and six with 64-detector CT angiography. The pooled sensitivity and specificity for detecting a greater than 50% stenosis per segment were 0.93 (95% confidence interval [CI]: 0.88, 0.97) and 0.96 (95% CI: 0.96, 0.97) for 64-detector CT angiography, 0.83 ( 95% CT: 0.76, 0.90) and 0.96 ( 95% CI: 0.95, 0.97) for 16-detector CT angiography, and 0.84 ( 95% CI: 0.81, 0.88) and 0.93 (95% CI: 0.91, 0.95) for four-detector CT angiography, respectively. Results of regression analysis indicated that the diagnostic performance significantly improved with the newer generations of multidetector CT scanners (64- and 16-detector vs four-detector units), adjusted for exclusion of nonassessable segments, and contrast agent concentration used ( P <.05). Simultaneously, the nonassessable proportion of segments significantly decreased with the newer generations of multidetector CT scanners, adjusted for heart rate, prevalence of significant disease, and mean age. Conclusion: With the newer generations of multidetector CT scanners, the diagnostic performance for the assessment of coronary artery disease has significantly improved, and the proportion of nonassessable segments has decreased.
引用
收藏
页码:419 / 428
页数:10
相关论文
共 83 条
[1]   Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation [J].
Achenbach, S ;
Ropers, D ;
Pohle, FK ;
Raaz, D ;
von Erffa, J ;
Yilmaz, A ;
Muschiol, G ;
Daniel, WG .
EUROPEAN HEART JOURNAL, 2005, 26 (19) :1978-1986
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]   Noninvasive detection of coronary stenosis using 16-slice detector computed tomography in carefully selected patients [J].
Beck, T ;
Kuettner, A ;
Burgstahler, C ;
Brückner, A ;
Heuschmid, M ;
Herdeg, C ;
Kopp, AE ;
Claussen, CD ;
Schroeder, S .
MEDIZINISCHE KLINIK, 2004, 99 (11) :645-650
[4]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[5]   A RANDOM-EFFECTS REGRESSION-MODEL FOR METAANALYSIS [J].
BERKEY, CS ;
HOAGLIN, DC ;
MOSTELLER, F ;
COLDITZ, GA .
STATISTICS IN MEDICINE, 1995, 14 (04) :395-411
[6]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
CLINICAL CHEMISTRY, 2003, 49 (01) :1-6
[7]   Image quality and diagnostic accuracy of 16-slice multidetector computed tomography for the detection of coronary artery disease in obese patients [J].
Burgstahler, C ;
Beck, T ;
Kuettner, A ;
Reimann, A ;
Kopp, AF ;
Heuschmid, M ;
Claussen, CD ;
Schroeder, S .
INTERNATIONAL JOURNAL OF OBESITY, 2006, 30 (03) :569-573
[8]   Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Belgrano, M ;
Malagutti, P ;
Meijboom, BW ;
Midiri, M ;
de Feyter, PJ ;
Krestin, GP .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (01) :101-105
[9]  
Cademartiri F, 2005, RADIOL MED, V110, P42
[10]   Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Lemos, PA ;
Saia, F ;
Runza, G ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (10) :1225-1227