Four-Dimensional MRI Using Three-Dimensional Radial Sampling with Respiratory Self-Gating to Characterize Temporal Phase-Resolved Respiratory Motion in the Abdomen

被引:74
作者
Deng, Zixin [1 ,2 ]
Pang, Jianing [1 ,3 ]
Yang, Wensha [4 ]
Yue, Yong [4 ]
Sharif, Behzad [1 ]
Tuli, Richard [4 ]
Li, Debiao [1 ,2 ]
Fraass, Benedick [4 ]
Fan, Zhaoyang [1 ]
机构
[1] Cedars Sinai Med Ctr, Dept Biomed Sci, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA USA
[3] Northwestern Univ, Dept Radiol & Biomed Engn, Chicago, IL 60611 USA
[4] Cedars Sinai Med Ctr, Dept Radiat Oncol, Los Angeles, CA 90048 USA
关键词
4D-MRI; 3D radial sampling; self-gating; respiratory motion; hysteresis; radiotherapy planning; HEART CORONARY MRA; CARDIAC CINE MRI; K-T BLAST; DYNAMIC MRI; RADIOTHERAPY; RECONSTRUCTION; SENSE; COMPENSATION; VARIABILITY; ANGIOGRAPHY;
D O I
10.1002/mrm.25753
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a four-dimensional MRI (4D-MRI) technique to characterize the average respiratory tumor motion for abdominal radiotherapy planning. Methods: A continuous spoiled gradient echo sequence was implemented with 3D radial trajectory and 1D self-gating for respiratory motion detection. Data were retrospectively sorted into different respiratory phases based on their temporal locations within a respiratory cycle, and each phase was reconstructed by means of a self-calibrating CG-SENSE program. Motion phantom, healthy volunteer and patient studies were performed to validate the respiratory motion detected by the proposed method against that from a 2D real-time protocol. Results: The proposed method successfully visualized the respiratory motion in phantom and human subjects. The 4D-MRI and real-time 2D-MRI yielded comparable superior-inferior (SI) motion amplitudes (intraclass correlation = 0.935) with up-to one pixel mean absolute differences in SI displacements over 10 phases and high cross-correlation between phase-resolved displacements (phantom: 0.985; human: 0.937-0.985). Comparable anterior-posterior and left-right displacements of the tumor or gold fiducial between 4D and real-time 2D-MRI were also observed in the two patients, and the hysteresis effect was shown in their 3D trajectories. Conclusion: We demonstrated the feasibility of the proposed 4D-MRI technique to characterize abdominal respiratory motion, which may provide valuable information for radiotherapy planning. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1574 / 1585
页数:12
相关论文
共 50 条
  • [1] Evaluation of potential internal target volume of liver tumors using
    Akino, Yuichi
    Oh, Ryoong-Jin
    Masai, Norihisa
    Shiomi, Hiroya
    Inoue, Toshihiko
    [J]. MEDICAL PHYSICS, 2014, 41 (11)
  • [2] Generating multiple contrasts using single-shot radial T1 sensitive and insensitive steady-state imaging
    Benkert, Thomas
    Bartsch, Andreas J.
    Blaimer, Martin
    Jakob, Peter M.
    Breuer, Felix A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) : 2129 - 2141
  • [3] Berthelsen Anne Kiil, 2007, Cancer Imaging, V7, P104, DOI 10.1102/1470-7330.2007.0013
  • [4] Analysis and compensation of eddy currents in balanced SSFP
    Bieri, O
    Markl, M
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 129 - 137
  • [5] MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning
    Blackall, J. M.
    Ahmad, S.
    Miquel, M. E.
    McClelland, J. R.
    Landau, D. B.
    Hawkes, D. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17) : 4147 - 4169
  • [6] Nonrigid Motion Modeling of the Liver From 3-D Undersampled Self-Gated Golden-Radial Phase Encoded MRI
    Buerger, C.
    Clough, R. E.
    King, A. P.
    Schaeffter, T.
    Prieto, C.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (03) : 805 - 815
  • [7] Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study
    Cai, Jing
    Chang, Zheng
    Wang, Zhiheng
    Segars, William Paul
    Yin, Fang-Fang
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6384 - 6394
  • [8] Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    Carr, JC
    Simonetti, O
    Bundy, J
    Li, DB
    Pereles, S
    Finn, JP
    [J]. RADIOLOGY, 2001, 219 (03) : 828 - 834
  • [9] Temporal Stability of Adaptive 3D Radial MRI Using Multidimensional Golden Means
    Chan, Rachel W.
    Ramsay, Elizabeth A.
    Cunningham, Charles H.
    Plewes, Donald B.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 354 - 363
  • [10] Ciernik IF, 2004, MALIGNANT LIVER TUMO, P101