The Influence of Rotary Blood Pump Speed Modulation on the Risk of Intraventricular Thrombosis

被引:28
|
作者
Liao, Sam [1 ,2 ,3 ]
Wu, Eric L. [2 ,4 ]
Neidlin, Michael [3 ]
Li, Zhiyong [1 ]
Simpson, Benjamin [5 ]
Gregory, Shaun D. [2 ,4 ,6 ]
机构
[1] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Kelvin Grove, Qld 4059, Australia
[2] Prince Charles Hosp, Crit Care Res Grp, Innovat Cardiovasc Engn & Technol Lab, Chermside, Qld, Australia
[3] Rhein Westfal TH Aachen, Helmholtz Inst, Inst Appl Med Engn, Dept Cardiovasc Engn, Aachen, Germany
[4] Univ Queensland, Sch Med, St Lucia, Qld, Australia
[5] Nottingham Trent Univ, Dept Engn, Clifton Lane, Nottingham, England
[6] Monash Univ, Dept Mech & Aerosp Engn, Clayton, Vic, Australia
基金
英国医学研究理事会;
关键词
Heart failure; Pulsation; Computational model; Ventricular assist device; Ventricular flow; Cannula; VENTRICULAR ASSIST DEVICE; VASCULAR PULSATILITY; FLOW; STASIS; INFLOW; IMPACT; HEART; PULSE; SITE;
D O I
10.1111/aor.13330
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rotary left ventricular assist devices (LVADs) are commonly operated at a constant speed, attenuating blood flow pulsatility. Speed modulation of rotary LVADs has been demonstrated to improve vascular pulsatility and pump washout. The effect of LVAD speed modulation on intraventricular flow dynamics is not well understood, which may have an influence on thromboembolic events. This study aimed to numerically evaluate intraventricular flow characteristics with a speed modulated LVAD. A severely dilated anatomical left ventricle was supported by a HeartWare HVAD in a three-dimensional multiscale computational fluid dynamics model. Three LVAD operating scenarios were evaluated: constant speed and sinusoidal co- and counter-pulsation. In all operating scenarios, the mean pump speed was set to restore the cardiac output to 5.0 L/min. Co- and counter-pulsation was speed modulated with an amplitude of 750 rpm. The risk of thrombosis was evaluated based on blood residence time, ventricular washout, kinetic energy densities, and a pulsatility index map. Blood residence time for co-pulsation was on average 1.8 and 3.7% lower than constant speed and counter-pulsation mode, respectively. After introducing fresh blood to displace preexisting blood for 10 cardiac cycles, co-pulsation had 1.5% less old blood in comparison to counter-pulsation. Apical energy densities were 84 and 27% higher for co-pulsation in comparison to counter-pulsation and constant speed mode, respectively. Co-pulsation had an increased pulsatility index around the left ventricular outflow tract and mid-ventricle. Improved flow dynamics with co-pulsation was caused by increased E-wave velocities which minimized blood stasis. In the studied scenario and from the perspective of intraventricular flow dynamics, co-pulsation of rotary LVADs could minimize the risk of intraventricular thrombosis.
引用
收藏
页码:943 / 953
页数:11
相关论文
共 50 条
  • [1] Feasibility of Pump Speed Modulation for Restoring Vascular Pulsatility with Rotary Blood Pumps
    Ising, Mickey S.
    Sobieski, Michael A.
    Slaughter, Mark S.
    Koenig, Steven C.
    Giridharan, Guruprasad A.
    ASAIO JOURNAL, 2015, 61 (05) : 526 - 532
  • [2] Asymmetric speed modulation of a rotary blood pump affects ventricular unloading
    Pirbodaghi, Tohid
    Weber, Alberto
    Axiak, Shannon
    Carrel, Thierry
    Vandenberghe, Stijn
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (02) : 383 - 388
  • [3] Effect of rotary blood pump pulsatility on potential parameters of blood compatibility and thrombosis in inflow cannula tips
    Wong, Kai Chun
    Buesen, Martin
    Benzinger, Carrie
    Gaeng, Rene
    Bezema, Mirko
    Greatrex, Nicholas
    Schmitz-Rode, Thomas
    Steinseifer, Ulrich
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (12): : 875 - 887
  • [4] Speed Modulation of the HeartWare HVAD to Assess In Vitro Hemocompatibility of Pulsatile and Continuous Flow Regimes in a Rotary Blood Pump
    Horobin, Jarod T.
    Simmonds, Michael J.
    Nandakumar, Deepika
    Gregory, Shaun D.
    Tansley, Geoff
    Pauls, Jo P.
    Girnghuber, Angela
    Balletti, Nicoletta
    Fraser, John F.
    ARTIFICIAL ORGANS, 2018, 42 (09) : 879 - 890
  • [5] Numerical hemolysis performance evaluation of a rotary blood pump under different speed modulation profiles
    Huang, Feng
    Lei, Huan
    Ying, Shunv
    Fu, Yang
    Li, Qipeng
    Ruan, Xiaodong
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [6] Experimental investigation of the influence of the hydraulic performance of an axial blood pump on intraventricular blood flow
    Liu, Guang-Mao
    Jiang, Fu-Qing
    Yang, Xiao-Han
    Wei, Run-Jie
    Hu, Sheng-Shou
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (12): : 980 - 989
  • [7] Understanding the influence of left ventricular assist device inflow cannula alignment and the risk of intraventricular thrombosis
    Neidlin, Michael
    Liao, Sam
    Li, Zhiyong
    Simpson, Benjamin
    Kaye, David M.
    Steinseifer, Ulrich
    Gregory, Shaun
    BIOMEDICAL ENGINEERING ONLINE, 2021, 20 (01)
  • [8] Rotary Blood Pump Control Strategy for Preventing Left Ventricular Suction
    Wang, Yu
    Koenig, Steven C.
    Slaughter, Mark S.
    Giridharan, Guruprasad A.
    ASAIO JOURNAL, 2015, 61 (01) : 21 - 30
  • [9] Rotary pump speed modulation for generating pulsatile flow and phasic Left ventricular volume unloading in a bovine model of chronic ischemic heart failure
    Soucy, Kevin G.
    Giridharan, Guruprasad A.
    Choi, Young
    Sobieski, Michael. A.
    Monreal, Gretel
    Cheng, Allen
    Schumer, Erin
    Slaughter, Mark S.
    Koenig, Steven C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (01): : 122 - 131
  • [10] Mitral Valve Regurgitation with a Rotary Left Ventricular Assist Device: The Haemodynamic Effect of Inlet Cannulation Site and Speed Modulation
    Gregory, Shaun D.
    Stevens, Michael C.
    Wu, Eric L.
    Pauls, Jo P.
    Kleinheyer, Matthias
    Fraser, John F.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (09) : 2674 - 2682