Disparity in disinfection byproducts concentration between hot and cold tap water

被引:31
|
作者
Liu, Boning [1 ]
Reckhow, David A. [1 ]
机构
[1] Univ Massachusetts, Dept Civil & Environm Engn, Amherst, MA 01003 USA
关键词
Disinfection byproducts; Water heater; Premise plumbing; Tap water; Distribution system; SIMULATED DISTRIBUTION-SYSTEM; DRINKING-WATER; HALOACETIC ACIDS; HOUSEHOLD WATER; HUMIC MATERIALS; DBP FORMATION; TRIHALOMETHANES; CHLORINATION; CHLOROFORM; EXPOSURE;
D O I
10.1016/j.watres.2014.11.045
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The quality of water entering a distribution system may differ substantially from the quality at the point of exposure to the consumer. This study investigated temporal variations in the levels of regulated and non-regulated disinfection byproducts (DBPs) in cold and hot tap water in a home on a medium-sized municipal water system. In addition, samples were collected directly from the water plant with some being held in accordance with a simulated distribution system (SDS) test protocol. The location for this work was a system in western Massachusetts, USA that uses free chlorine as a final disinfectant. Very little short term variability of DBPs at the point of entry (POE) was observed. The concentration of DBPs in the time-variable SDS test was similar to concentrations in the cold water tap. For most DBPs, the concentrations continued to increase as the cold water tap sample was held for the time-variable SDS incubation period. However, the impact of heating on DBP levels was compound specific. For example, the concentrations of trihalomethanes (THMs), dichloroacetic acid (DCAA) and chloropicrin (CP) were substantially higher in the hot water tap than in the cold water time-variable SDS samples. In contrast, the concentration of trichloroacetic acid (TCAA) was lower in the heated hot tap water, but about equal to that observed in the cold tap water. The situation was more pronounced for dichloroacetonitrile (DCAN), bromodichloroacetic acid (BDCAA), bromochloroacetic acid (BCAA) and 1,1,1-trichloropropanone (TCP), which all showed lower concentrations in the hot water then in either of the cold water samples (instantaneous or time-variable SDS). The latter was viewed as a clear indication of thermally-induced decomposition. The ratio of unknown total organic halide (UTOX) to TOX was substantially lower in the hot tap water as the THM to TOX ratio became correspondingly larger. The results of this study show that DBP exposure in the home is not well represented by concentrations measured in cold water taps where most compliance monitoring is done. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:196 / 204
页数:9
相关论文
共 50 条
  • [21] Boiling of Simulated Tap Water: Effect on Polar Brominated Disinfection Byproducts, Halogen Speciation, and Cytotoxicity
    Pan, Yang
    Zhang, Xiangru
    Wagner, Elizabeth D.
    Osiol, Jennifer
    Plewa, Michael J.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (01) : 149 - 156
  • [22] Prevalence and Trends of Drinking Water Disinfection Byproducts-Related Cancers in Addis Ababa, Ethiopia
    Tafesse, Nebiyou
    Porcelli, Massimiliano
    Gari, Sirak Robele
    Ambelu, Argaw
    ENVIRONMENTAL HEALTH INSIGHTS, 2022, 16
  • [23] Drinking water disinfection byproducts and risk of orofacial clefts in the National Birth Defects Prevention Study
    Weyer, Peter
    Rhoads, Anthony
    Suhl, Jonathan
    Luben, Thomas J.
    Conway, Kristin M.
    Langlois, Peter H.
    Shen, Dereck
    Liang, Dong
    Puzhankara, Soman
    Anderka, Marlene
    Bell, Erin
    Feldkamp, Marcia L.
    Hoyt, Adrienne T.
    Mosley, Bridget
    Reefhuis, Jennita
    Romitti, Paul A.
    BIRTH DEFECTS RESEARCH, 2018, 110 (12): : 1027 - 1042
  • [24] Progressive Increase in Disinfection Byproducts and Mutagenicity from Source to Tap to Swimming Pool and Spa Water: Impact of Human Inputs
    Daiber, Eric J.
    DeMarini, David M.
    Ravuri, Sridevi A.
    Liberatore, Hannah K.
    Cuthbertson, Amy A.
    Thompson-Klemish, Alexis
    Byer, Jonathan D.
    Schmid, Judith E.
    Afifi, Mehrnaz Z.
    Blatchley, Ernest R., III
    Richardson, Susan D.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (13) : 6652 - 6662
  • [25] Recent Advances on Electrochemical Sensors for the Detection of Organic Disinfection Byproducts in Water
    Zhang, Wei
    Wang, Lue
    Yang, Yuesuo
    Gaskin, Paul
    Teng, Kar Seng
    ACS SENSORS, 2019, 4 (05) : 1138 - 1150
  • [26] Occurrence of disinfection by-products in tap water distribution systems and their associated health risk
    Lee, Jin
    Kim, Eun-Sook
    Roh, Bang-Sik
    Eom, Seog-Won
    Zoh, Kyung-Duk
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (09) : 7675 - 7691
  • [27] The occurrence, formation and transformation of disinfection byproducts in the water distribution system: A review
    Dong, Feilong
    Zhu, Jiani
    Li, Jinzhe
    Fu, Chuyun
    He, Guilin
    Lin, Qiufeng
    Li, Cong
    Song, Shuang
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 867
  • [28] Formation of disinfection byproducts during chlorination of secondary effluent and renovated water
    Rebhun, M
    HellerGrossman, L
    Manka, J
    WATER ENVIRONMENT RESEARCH, 1997, 69 (06) : 1154 - 1162
  • [29] Subacute Toxicity Assessment of Water Disinfection Byproducts on Zebrafish
    Racz, Gergely
    Csenki, Zsolt
    Kovacs, Robert
    Hegyi, Arpad
    Baska, Ferenc
    Sujbert, Laszlo
    Zsakovics, Ivett
    Kis, Renata
    Gustafson, Ryan
    Urbanyi, Bela
    Szende, Bela
    PATHOLOGY & ONCOLOGY RESEARCH, 2012, 18 (03) : 579 - 584
  • [30] Formation of Aromatic Halogenated Disinfection Byproducts in Swimming Pool Water during Chlorination: Organic Precursors and Mechanisms
    Wang, Junjie
    Wu, Hongyu
    Ma, Tao
    Chen, Haoran
    Chen, Chuze
    Wang, Yuting
    Xian, Qiming
    Gong, Tingting
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (49) : 21782 - 21793