Disparity in disinfection byproducts concentration between hot and cold tap water

被引:31
|
作者
Liu, Boning [1 ]
Reckhow, David A. [1 ]
机构
[1] Univ Massachusetts, Dept Civil & Environm Engn, Amherst, MA 01003 USA
关键词
Disinfection byproducts; Water heater; Premise plumbing; Tap water; Distribution system; SIMULATED DISTRIBUTION-SYSTEM; DRINKING-WATER; HALOACETIC ACIDS; HOUSEHOLD WATER; HUMIC MATERIALS; DBP FORMATION; TRIHALOMETHANES; CHLORINATION; CHLOROFORM; EXPOSURE;
D O I
10.1016/j.watres.2014.11.045
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The quality of water entering a distribution system may differ substantially from the quality at the point of exposure to the consumer. This study investigated temporal variations in the levels of regulated and non-regulated disinfection byproducts (DBPs) in cold and hot tap water in a home on a medium-sized municipal water system. In addition, samples were collected directly from the water plant with some being held in accordance with a simulated distribution system (SDS) test protocol. The location for this work was a system in western Massachusetts, USA that uses free chlorine as a final disinfectant. Very little short term variability of DBPs at the point of entry (POE) was observed. The concentration of DBPs in the time-variable SDS test was similar to concentrations in the cold water tap. For most DBPs, the concentrations continued to increase as the cold water tap sample was held for the time-variable SDS incubation period. However, the impact of heating on DBP levels was compound specific. For example, the concentrations of trihalomethanes (THMs), dichloroacetic acid (DCAA) and chloropicrin (CP) were substantially higher in the hot water tap than in the cold water time-variable SDS samples. In contrast, the concentration of trichloroacetic acid (TCAA) was lower in the heated hot tap water, but about equal to that observed in the cold tap water. The situation was more pronounced for dichloroacetonitrile (DCAN), bromodichloroacetic acid (BDCAA), bromochloroacetic acid (BCAA) and 1,1,1-trichloropropanone (TCP), which all showed lower concentrations in the hot water then in either of the cold water samples (instantaneous or time-variable SDS). The latter was viewed as a clear indication of thermally-induced decomposition. The ratio of unknown total organic halide (UTOX) to TOX was substantially lower in the hot tap water as the THM to TOX ratio became correspondingly larger. The results of this study show that DBP exposure in the home is not well represented by concentrations measured in cold water taps where most compliance monitoring is done. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:196 / 204
页数:9
相关论文
共 50 条
  • [1] Effects of tap water processing on the concentration of disinfection by-products
    Rahman, Md. Bayzidur
    Driscoll, Tim
    Clements, Mark
    Armstrong, Bruce K.
    Cowie, Christine T.
    JOURNAL OF WATER AND HEALTH, 2011, 9 (03) : 507 - 514
  • [2] Occurrence and modeling of disinfection byproducts in distributed water of a megacity in China: Implications for human health
    Pang, Zhen
    Zhang, Peifeng
    Chen, Xinyi
    Dong, Feilong
    Deng, Jing
    Li, Cong
    Liu, Junping
    Ma, Xiaoyan
    Dietrich, Andrea M.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 848
  • [3] Revisiting the effect of boiling on halogenated disinfection byproducts, total organic halogen, and cytotoxicity in simulated tap water
    Zhao, Jiayan
    Han, Liangliang
    Tan, Suo
    Chu, Wenhai
    Dong, Huiyu
    Zhou, Qing
    Pan, Yang
    CHEMOSPHERE, 2022, 309
  • [4] Degradation of disinfection byproducts in drinking water
    Lekkas, TD
    Nikolaou, AD
    ENVIRONMENTAL ENGINEERING SCIENCE, 2004, 21 (04) : 493 - 506
  • [5] Photolytic dehalogenation of disinfection byproducts in water by natural sunlight irradiation
    Abusallout, Ibrahim
    Hua, Guanghui
    CHEMOSPHERE, 2016, 159 : 184 - 192
  • [6] Disinfection Byproducts in Intermittent Piped Water Supplies
    Roberts, Thomas
    Reckhow, David
    Kumpel, Emily
    Chavarria, Karina A.
    ACS ES&T WATER, 2023, 3 (12): : 3767 - 3781
  • [7] Occurrence and Cytotoxicity of Aliphatic and Aromatic Halogenated Disinfection Byproducts in Indoor Swimming Pool Water and Their Incoming Tap Water
    Wang, Junjie
    Zhang, Meiqi
    Hu, Shaoyang
    Xian, Qiming
    Chen, Haoran
    Gong, Tingting
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (24) : 17763 - 17775
  • [8] Disinfection byproducts in US drinking water and cancer mortality
    Mendy, Angelico
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2024,
  • [9] Effects of ascorbate and carbonate on the conversion and developmental toxicity of halogenated disinfection byproducts during boiling of tap water
    Liu, Jiaqi
    Li, Yu
    Jiang, Jingyi
    Zhang, Xiangru
    Sharma, Virender K.
    Sayes, Christie M.
    CHEMOSPHERE, 2020, 254
  • [10] Identification, toxicity and control of iodinated disinfection byproducts in cooking with simulated chlor(am)inated tap water and iodized table salt
    Pan, Yang
    Zhang, Xiangru
    Li, Yu
    WATER RESEARCH, 2016, 88 : 60 - 68