A cylindrical quadrupole ion trap in combination with an electrospray ion source for gas-phase luminescence and absorption spectroscopy

被引:47
作者
Stockett, Mark H. [1 ]
Houmoller, Jorgen [1 ]
Stochkel, Kristian [1 ]
Svendsen, Annette [1 ]
Nielsen, Steen Brondsted [1 ]
机构
[1] Aarhus Univ, Dept Phys & Astron, Aarhus, Denmark
关键词
LASER-INDUCED FLUORESCENCE; RESONANCE ENERGY-TRANSFER; CONFORMATIONAL DYNAMICS; PROTEIN CHROMOPHORES; MOLECULAR-IONS; PROBE; PHOTODISSOCIATION; EXCITATION; LIFETIMES; CATIONS;
D O I
10.1063/1.4948316
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A relatively simple setup for collection and detection of light emitted from isolated photo-excited molecular ions has been constructed. It benefits from a high collection efficiency of photons, which is accomplished by using a cylindrical ion trap where one end-cap electrode is a mesh grid combined with an aspheric condenser lens. The geometry permits nearly 10% of the emitted light to be collected and, after transmission losses, approximately 5% to be delivered to the entrance of a grating spectrometer equipped with a detector array. The high collection efficiency enables the use of pulsed tunable lasers with low repetition rates (e.g., 20 Hz) instead of continuous wave (cw) lasers or very high repetition rate (e.g., MHz) lasers that are typically used as light sources for gas-phase fluorescence experiments on molecular ions. A hole has been drilled in the cylinder electrode so that a light pulse can interact with the ion cloud in the center of the trap. Simulations indicate that these modifications to the trap do not significantly affect the storage capability and the overall shape of the ion cloud. The overlap between the ion cloud and the laser light is basically 100%, and experimentally >50% of negatively charged chromophore ions are routinely photodepleted. The performance of the setup is illustrated based on fluorescence spectra of several laser dyes, and the quality of these spectra is comparable to those reported by other groups. Finally, by replacing the optical system with a channeltron detector, we demonstrate that the setup can also be used for gas-phase action spectroscopy where either depletion or fragmentation is monitored to provide an indirect measurement on the absorption spectrum of the ion. Published by AIP Publishing.
引用
收藏
页数:9
相关论文
共 46 条
[31]   iSELECTION: An Instrument to Study the Kinetics of Isomer-Selected Gas-Phase Ion-Molecule Reactions [J].
Rossi, Corentin ;
Rasmussen, Anne P. ;
Gans, Berenger ;
Jasik, Juraj ;
Zabka, Jan ;
Albaret, Marc ;
Bauduin, Hugo ;
Charriere, Christophe ;
Dugal, Jean-Philippe ;
Guigand, Jerome ;
Le Bris, Catherine ;
Jacovella, Ugo .
CHEMISTRY-METHODS, 2025,
[32]   THE DYNAMICS OF PHOTODISSOCIATION OF THE GAS-PHASE (N2O.H2O)+ CLUSTER ION [J].
GRAUL, ST ;
KIM, HS ;
BOWERS, MT .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 117 (1-3) :507-536
[33]   Selective Gas-Phase Ion/Ion Reactions: Enabling Disulfide Mapping via Oxidation and Cleavage of Disulfide Bonds in Intermolecularly-Linked Polypeptide Ions [J].
Pilo, Alice L. ;
McLuckey, Scott A. .
ANALYTICAL CHEMISTRY, 2016, 88 (18) :8972-8979
[34]   Ion mobility spectrometry coupled to laser-induced fluorescence for probing the electronic structure and conformation of gas-phase ions [J].
Frankevich, V. E. ;
Barylyuk, K. V. ;
Sinues, P. Martinez-Lozano ;
Zenobi, R. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (13) :1215-1219
[35]   Gas-Phase Collisions with Trimethylamine-N-Oxide Enable Activation-Controlled Protein Ion Charge Reduction [J].
Kaldmae, Margit ;
Osterlund, Nicklas ;
Lianoudaki, Danai ;
Sahin, Cagla ;
Bergman, Peter ;
Nyman, Tomas ;
Kronqvist, Nina ;
Ilag, Leopold L. ;
Allison, Timothy M. ;
Marklund, Erik G. ;
Landreh, Michael .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (08) :1385-1388
[36]   Ion mobility spectrometry coupled to laser-induced fluorescence for probing the electronic structure and conformation of gas-phase ions [J].
V. E. Frankevich ;
K. V. Barylyuk ;
P. Martinez-Lozano Sinues ;
R. Zenobi .
Journal of Analytical Chemistry, 2014, 69 :1215-1219
[37]   Identification and fragmentation pathways of caffeine metabolites in urine samples via liquid chromatography with positive electrospray ionization coupled to a hybrid quadrupole linear ion trap (LTQ) and Fourier transform ion cyclotron resonance mass spectrometry and tandem mass spectrometry [J].
Bianco, Giuliana ;
Abate, Salvatore ;
Labella, Cristiana ;
Cataldi, Tommaso R. I. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (07) :1065-1074
[38]   Infrared spectroscopy of closed s-shell gas-phase M+(N2O)n (M = Li, Al) ion-molecule complexes* [J].
Cunningham, Ethan M. ;
Gentleman, Alexander S. ;
Beardsmore, Peter W. ;
Mackenzie, Stuart R. .
MOLECULAR PHYSICS, 2019, 117 (21) :2990-3000
[39]   Selective Covalent Chemistry via Gas-Phase Ion/ion Reactions: An Exploration of the Energy Surfaces Associated with N-Hydroxysuccinimide Ester Reagents and Primary Amines and Guanidine Groups [J].
Bu, Jiexun ;
Fisher, Christine M. ;
Gilbert, Joshua D. ;
Prentice, Boone M. ;
McLuckey, Scott A. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (06) :1089-1098
[40]   Conformation of alkali metal ion-calix[4]arene complexes investigated by IR spectroscopy in the gas phase [J].
Wada, Kozue ;
Kida, Motoki ;
Muramatsu, Satoru ;
Ebata, Takayuki ;
Inokuchi, Yoshiya .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2019, 21 (31) :17082-17086