An electrochemical sensor for Cd2+ based on the inducing adsorption ability of I-

被引:23
|
作者
Li, Gang
Wan, Chidan
Ji, Zhiming
Wu, Kangbing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Chem, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Tongji Med Coll, Union Hosp, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
cadmium; electrochemical determination; acetylene black; inducing adsorption;
D O I
10.1016/j.snb.2006.11.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, an electrochemical sensor for sensitive and simple determination of Cd2+, was fabricated based on the excellent properties of acetylene black (AB) and strong inducing adsorption ability of I-. In pH 3.6 HAc-NaAc buffer containing 5.0 x 10(-3) mol L-1 I-, Cd2+ was induced to accumulate at AB paste electrode surface under the inducing adsorption of I-, and then reduced to Cd at -1.10V During the following potential sweep from -1.10 to -0.40V, reduced Cd was oxidized, resulting in a sensitive and well-shaped stripping peak at -0.83 V. Based on this, a new electrochemical method was developed for Cd2+, analysis. The linear range is found to be 5.0 x 10(-8) to 2.0 x 10(-6) mol L-1, and the detection limit is 2.0 x 10-8 mol L-1. Finally, this sensor was successfully used to detect Cd 21 in water samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 50 条
  • [41] In Vitro Bioadsorption of Cd2+ Ions: Adsorption Isotherms, Mechanism, and an Insight to Mycoremediation
    Kumar, Raman
    Sharma, Priyanka
    Umar, Ahmad
    Kumar, Rajeev
    Singh, Namita
    Joshi, P. K.
    Alharthi, Fahad A.
    Alghamdi, Abdulaziz Ali
    Al-Zaqri, Nabil
    PROCESSES, 2020, 8 (09)
  • [42] A ratiometric fluorescent sensor based on dual-emissive carbon dot for the selective detection of Cd2+
    Keerthana, P.
    Das, Avijit Kumar
    Bharath, M.
    Ghosh, Munmun
    Varghese, Anitha
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (02):
  • [43] Studies On Preparation and Adsorption Behavior of Cd2+ Ions-Imprinted Polymer
    Shi, Yingying
    Zhang, Qianghua
    Feng, Liangdong
    Xiong, Qingping
    CHEMICAL ENGINEERING AND MATERIAL PROPERTIES II, 2012, 549 : 419 - 422
  • [44] A highly-sensitive electrochemical sensor for the simultaneous detection of Cd2+ and Pb2+ using liquid phase-exfoliated graphene
    Liu, Guishen
    Chen, Jianpeng
    Hou, Xiaodong
    Huang, Wensheng
    ANALYTICAL METHODS, 2014, 6 (15) : 5760 - 5765
  • [45] Synthesis of a Schiff Base for Carbon Sphere Modification and Cd2+ Electrochemical Determination
    Li, Na
    Zhang, Xin
    Guo, Hui
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (12): : 11571 - 11579
  • [46] A novel "turn on" fluorescent sensor based on hydroxy-triphenylamine for Zn2+ and Cd2+ ions in MeCN
    Erdemir, Serkan
    Malkondu, Sait
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 1225 - 1229
  • [47] A diarylethene based multi-functional sensor for fluorescent detection of Cd2+ and colorimetric detection of Cu2+
    Liu, Hongling
    Cui, Shiqiang
    Shi, Fu
    Pu, Shouzhi
    DYES AND PIGMENTS, 2019, 161 : 34 - 43
  • [48] A new fluorescent sensor for Cd2+ and its application in living cells imaging
    Liu, Xiao-yan
    Liu, Da-ying
    Qi, Jing
    Cui, Zhi-gang
    Chang, He-xi
    He, Hua-rui
    Yang, Guang-ming
    TETRAHEDRON LETTERS, 2015, 56 (11) : 1322 - 1327
  • [49] Adsorption Behavior of Cd2+ and Zn2+ onto Natural Egyptian Bentonitic Clay
    Burham, Nagwa
    Sayed, Mahmoud
    MINERALS, 2016, 6 (04):
  • [50] Synthesis of a ratiometric fluorescent peptide sensor for the highly selective detection of Cd2+
    Li, Yan
    Li, Lianzhi
    Pu, Xuewei
    Ma, Guolin
    Wang, Erqiong
    Kong, Jinming
    Liu, Zhipeng
    Liu, Yangzhong
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2012, 22 (12) : 4014 - 4017