A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement

被引:14
作者
Pal, Yash [1 ]
Swarup, A. [1 ]
Singh, Bhim [2 ]
机构
[1] NIT, Dept Elect Engn, Kurukshetra, Haryana, India
[2] IIT, Dept Elect Engn, Delhi, India
关键词
Power quality; UPQC; Load balancing; Power factor correction; Voltage harmonic mitigation; Current harmonic mitigation; Source neutral current mitigation; ACTIVE-FILTERS; CONDITIONER;
D O I
10.5370/JEET.2012.7.1.1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The current paper presents a novel control strategy of a three-phase, four-wire Unified Power Quality (UPQC) to improve power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a common dc bus capacitor. The realization of shunt APF is carried out using a three-phase, four-leg Voltage Source Inverter (VSI), and the series APF is realized using a three-phase, three-leg VSI. To extract the fundamental source voltages as reference signals for series APF, a zero-crossing detector and sample-and-hold circuits are used. For the control of shunt APF, a simple scheme based on the real component of fundamental load current (I Cos Phi) with reduced numbers of current sensors is applied. The performance of the applied control algorithm is evaluated in terms of power-factor correction, source neutral current mitigation, load balancing, and mitigation of voltage and current harmonics in a three-phase, four-wire distribution system for different combinations of linear and non-linear loads. The reference signals and sensed signals are used in a hysteresis controller to generate switching signals for shunt and series APFs. In this proposed UPQC control scheme, the current/voltage control is applied to the fundamental supply currents/voltages instead of fast-changing APF currents/voltages, thus reducing the computational delay and the required sensors. MATLAB/Simulink-based simulations that support the functionality of the UPQC are obtained.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 21 条
[1]   New trends in active filters for power conditioning [J].
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1312-1322
[2]  
[Anonymous], 2014, 5192014 IEEE
[3]   An universal active power line conditioner [J].
Aredes, M ;
Heumann, K ;
Watanabe, EH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (02) :545-551
[4]   Design, simulation, and analog circuit implementation of a three-phase shunt active filter using the I cos Φ algorithm [J].
Bhuvaneswari, G. ;
Nair, Manjula G. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (02) :1222-1235
[5]  
BHUVANESWARI G, 2006, C IEEE PEDES 06 DEC, P1
[6]  
Chen GZ, 2004, APPL POWER ELECT CO, P587
[7]  
Dugan R. C., 2006, ELECT POWER SYSTEM Q
[8]  
Fuchs EF, 2008, POWER QUALITY IN POWER SYSTEMS AND ELECTRICAL MACHINES, P1
[9]   The unified power quality conditioner: The integration of series- and shunt-active filters [J].
Fujita, H ;
Akagi, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (02) :315-322
[10]  
Ghosh A, 2004, 2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, P471